• 제목/요약/키워드: distorted power

검색결과 325건 처리시간 0.026초

Classification of Environmentally Distorted Acoustic Signals in Shallow Water Using Neural Networks : Application to Simulated and Measured Signal

  • Na, Young-Nam;Park, Joung-Soo;Chang, Duck-Hong;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권1E호
    • /
    • pp.54-65
    • /
    • 1998
  • This study attempts to test the classifying performance of a neural network and thereby examine its applicability to the signals distorted in a shallow water environment. Linear frequency modulated(LFM) signals are simulated by using an acoustic model and also measured through sea experiment. The network is constructed to have three layers and trained on both data sets. To get normalized power spectra as feature vectors, the study considers the three transforms : shot-time Fourier transform (STFT), wavelet transform (WT) and pseudo Wigner-Ville distribution (PWVD). After trained on the simulated signals over water depth, the network gives over 95% performance with the signal to noise ratio (SNR) being up to-10 dB. Among the transforms, the PWVD presents the best performance particularly in a highly noisy condition. The network performs worse with the summer sound speed profile than with the winter profile. It is also expected to present much different performance by the variation of bottom property. When the network is trained on the measured signals, it gives a little better results than that trained on the simulated data. In conclusion, the simulated signals are successfully applied to training a network, and the trained network performs well in classifying the signals distorted by a surrounding environment and corrupted by noise.

  • PDF

Optimal Control Design-based Gain Selection of an LCL-filtered Grid-connected Inverter in State-Space under Distorted Grid Environment

  • Tran, Vi-Thuy;Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.344-345
    • /
    • 2018
  • In order to alleviate the negative impacts of harmonically distorted grid condition on grid-connect inverters, an optimal control design-based gain selection scheme of an LCL-filtered grid-connected inverter and its ability to compensate selective harmonics are presented in this paper. By incorporating resonant terms into the control structure in the state-space to provide infinity gain at selected frequencies, the proposed control offers an excellent steady-state response even under distorted grid voltage. The proposed control scheme is achieved by using a state feedback controller for stabilization purpose and by augmenting the resonant terms as well as intergral term into a control structure for reference tracking and harmonic compensation. Furthermore, the optimal linear quadratic control approach is adopted for choosing an optimal feedback gain to ensure an asymptotic stability of the whole system. A discrete-time full state observer is also introduced into the proposed control scheme for the purpose of reducing a total number of sensors used in the inverter system. The simulation results are given to prove the effectiveness and validity of the proposed control scheme.

  • PDF

선형성 개선과 크기 축소를 위한 새로운 PBG 구조를 이용한 전력증폭기 설계 (Power Amplifier Design using the Novel PBG Structure for Linearity Improvement and Size Reduction)

  • 최재원;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제44권7호통권361호
    • /
    • pp.29-34
    • /
    • 2007
  • 본 논문은 전력증폭기의 크기를 줄이고 선형성을 개선하기 위한 새로운 광전자밴드갭 (PBG) 구조를 제시하였다. 제안된 구조는 비평면 제조 공정을 요구하지 않는 유전체 판위에 패턴을 뜬 2차원의 규칙적인 격자이다. 실험 결과를 통해서 보면, 이 구조는 접지 평면에 세 개의 셀을 식각시킨 기본적인 PBG와 distorted uniplanar compact_PBG (DUC_PBG)보다 더 넓은 저지대역과 더 높은 저지 특성을 갖는다. 이 새로운 PBG 구조는 선형성 개선을 위하여 전력증폭기에 적용되어 질 수 있다. 새로운 PBG 구조를 이용한 전력증폭기의 3차 혼변조 왜곡 (IMD3)은 코드분할 다중접속 (CDMA) 응용에서 -36.16 dBc이다. 제안된 PBG 구조가 없는 전력증폭기와 비교했을 때, 개선된 IMD3는 -13.49 dBc이다.

3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 불평형 및 왜곡 보상 (A Compensation of the Grid Current Unbalance and Distortion caused by the Grid Voltage Unbalance and Distortion in 3-Phase Bi-Directional DC to AC Inverter)

  • 양승대;김승민;최주엽;최익;송승호;이상철;이동하
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.161-168
    • /
    • 2013
  • This paper presents an algorithm of a compensation of the grid current distortion caused by the grid voltage unbalance and distortion in 3-phase bi-directional DC to AC inverter. Usually 3-phase grid system has unbalance and distortion because of connecting 1-phase and non-linear load with 3-phase load using same input node. Controlling 3-phase inverter by general method under the unbalanced and distorted grid voltage, the grid current has distortion. This distortion of the grid current cause the grid voltage distortion again. So, it need to control the grid current balanced and non-distorted, even the grid voltage gets unbalanced and distorted. There are some complex method to compensate the gird current distortion. it suggest simple method to solve the problem. Simulation and experiment is used to validate the proposed algorithm.

FCEV 구동용 DC-DC 컨버터 가변 DC-link 전압 제어에 의한 PWM 인버터의 전류 왜곡 저감 (Reduction of Current Distortion in PWM Inverter by Variable DC-link Voltage of DC-DC Converter for FCEV)

  • 고안열;김도윤;이정효;김영렬;원충연
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.572-581
    • /
    • 2014
  • A design and control method of DC/DC converter, which can control variable DC-link voltage to drive a fuel cell electric vehicle (FCEV), is proposed in this study. Given that a fuel cell has low-voltage and high-current characteristics, the required voltage for operating motor must be output through the DC/DC boost converter in the system to drive an FCEV. The proposed converter can choose the output voltage of battery or fuel cell in consideration of the driving mode, as well as control DC-link voltage in accordance with the back electromotive force. The switching lag-time to prevent shortage of pulse-width modulation inverter arms makes distorted current waveform caused by voltage distortion. Through this control method, the proposed converter can reduce the output voltage distortion and current ripple of the inverter, thereby reducing the distorted torque. Simulations and experimental results are presented to verify the reliability of the proposed DC/DC converter.

왜곡된 입력 전압을 고려한 PWM AC/DC 컨버터 제어기 (A Controller for PWM AC/DC Converter Considering Distorted Input Voltage)

  • 송홍석;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.1-8
    • /
    • 1997
  • PWM(Pulse Width Modulation) 컨버터의 제어에 있어서, 입력전압의 왜곡을 고려하지 않을 경우, 시스템의 성능 저하를 초래하게 된다. 본 논문은 왜곡된 3상 입력전압이 PWM 컨버터에 미치는 영향을 분석하고, 성능을 개선하기 위한 제어기를 설계한다. 제안된 방식은 단위 역률을 만족시키면서, THD(Total Harmonic Distortion) 및 DC-link 전압의 저차 ripple을 감소시킨다.

  • PDF

슬랙모선의 영향을 고려한 손실 제분배 조류계산 알고리즘 (Loss Redistribution Load Flow Algorithm considering Slack Bus Effects)

  • 박시우;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.528-530
    • /
    • 1995
  • In the conventional power flow calculations, the slack bus is assumed to undertake the total transmission loss for the convenience of numerical computation. This is an unrealistic assumption because, in real power system, the transmission loss is supplied by all the generators and makes the power flow calculation results somewhat distorted. This paper proposes a new loss redistribution algorithm that can reduce the distortion of power flow results. In the proposed method, the system power loss redistribution algorithm is added to the conventional power flow equations and jacobian elements that are related the real power are newly constructed. In each iteration step, the power output of each generator is updated to consider the effect of calculated total power losses. Finally the usefulness of proposed method are tested through the some appropriate case studies.

  • PDF

단상전원에 적합한 단일단 및 2단 역률개선회로 (Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source)

  • 김철진;유병규;김충식;김영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

광대역 주파수를 가진 전력 측정 변환기 (A watt-converter for a wideband frequency power measurement)

  • 박영태;정재갑;강전홍;유권상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2332-2334
    • /
    • 2004
  • A high bandwidth watt-converter, based on an inexpensive, commercially available, standard IC package, is described that covers a frequency ranges from DC to 100 kHz. The new resistive shunt for a wide-band frequency current measurement of the watt-converter was developed. The converter will use application in accurate power measurement under distorted and high frequency conditions. The advantages of the watt-converter are its simplicity, low cost and fast response time.

  • PDF