• Title/Summary/Keyword: distance-attenuation

Search Result 231, Processing Time 0.03 seconds

Environmental Impact Assessment of Uranium Anormaly in Stream System around the Shinbo Talc Mine (신보활석광산 주변에 형성된 우라늄 이상치가 지표수계 환경에 미치는 영향)

  • 나춘기;정재일
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.261-271
    • /
    • 2000
  • In order to evaluate the environmental impact of U anormaly in the drainage system around the Shinbo talc mine area, U contents, their distribution patterns, bioaccumulation and a-radioactivity in stream water, stream sediments and aquatic organisms were investigated. The U contents of stream water attenuated with increasing distance from the mine area. The same attenuation pattern is shown in stream sediments from mine to 0.75 km downstream, although these contain highly enriched U contents (24~83 mg/kg) comparing with the international average concentration of surface soils (0.79~11 mg/kg). However, U content increases abruptly in sediment at 1.5 km downstream, probably due to detrital migration and rediposition of U enriched sediments. Futhermore, enriched U in downstream sediments occur in high proportions of carbonate and Fe-Mn oxide bounded forms, which show high potential of a secondary pollution source. For aquatic organisms, bio accumulation degree of U are in the order: aquatic larvae>black snail>mountain frog>crawfish. Cultured trout by the U enrich groundwater (387 ${\mu}g$/l) shows U accumulation in the part of branchia (CRs 5.25) and bones (CRs 11.2) but not in flesh (CRs 0.03). Total a-radioactivity have been measured in the level as 0.47 nCi/l for groundwater, 2.94~18 nCi/kg${\cdot}$DW for organisms and 93~328 nCi/kg${\cdot}$DW for sediments.

  • PDF

Verification Techniques of the Distored iBeacon Information for Reliable Indoor Positioning Systems (신뢰성 있는 실내 위치 측위 시스템을 위한 왜곡된 iBeacon 정보의 검증 기법)

  • Yoon, Chang-Pyo;Hwang, Chi-Gon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.345-347
    • /
    • 2016
  • Recently location based services is being expanded into the indoor service that can not access to the outdoor location informations, such as GPS. Thus, the research and development of an indoor positioning system with BLE(Bluetooth Low Energy) iBeacon technology has expanded. However, RSSI (Received Signal Strength Indicator) that is used as the distance information between the terminal and for positioning iBeacon signal has a problem in that distortion occurs, information such as the signal attenuation and the delay due to the characteristics of radio waves. In this paper, we propose a reliable method of verifying iBeacon signal with the signal distortion problems for reliable indoor positioning systems.

  • PDF

A Modified Residual-based Extended Kalman Filter to Improve the Performance of WiFi RSSI-based Indoor Positioning (와이파이 수신신호세기를 사용하는 실내위치추정의 성능 향상을 위한 수정된 잔차 기반 확장 칼만 필터)

  • Cho, Seong Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.684-690
    • /
    • 2015
  • This paper presents a modified residual-based EKF (Extended Kalman Filter) for performance improvement of indoor positioning using WiFi RSSI (Received Signal Strength Indicator) measurement. Radio signal strength in indoor environments may have irregular attenuation characteristics due to obstacles such as walls, furniture, etc. Therefore, the performance of the RSSI-based positioning with the conventional trilateration method or Kalman filter is insufficient to provide location-based accurate information services. In order to enhance the performance of indoor positioning, in this paper, error analysis of the distance calculated by using the WiFi RSSI measurement is performed based on the radio propagation model. Then, an IARM (Irregularly Attenuated RSSI Measurement) error is defined. Also, it shows that the IARM error is included in the residual of the positioning filter. The IARM error is always positive. So, it is presented that the IARM error can be estimated by taking the absolute value of the residual. Consequently, accurate positioning can be achieved based on the IEM (IARM Error Mitigated) EKF with the residual modified by using the estimated IARM error. The performance of the presented IEM EKF is verified experimentally.

Measurement of Absorbed Dose at the Tissue Surface from a Plain $^{90}Sr+^{90}Y$ Beta Sources (조직 표면에서의 베타선 흡수선량 측정)

  • Hah, Suck-Ho;Kim, Jeong-Mook;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.17-26
    • /
    • 1991
  • Beta ray $(^{90}Sr+^{90}Y)$ absorbed dose at tissue surface was measured from the distance of 30cm by use of extrapolation chamber. In the measurement, following factors were considered: effective area of collecting electrode, polarity effect, ion recombination and window attenuation. The measured absorbed dose rate at tissue surface was $1.493{\mu}Gy/sec$ with ${\pm}2.9%$.

  • PDF

Development of Batteryless SAW-based Integrated Microsensor and Wireless Measurement Technique (무전지 SAW 기반 마이크로 통합센서 및 무선 측정기술 개발)

  • Oh, Hae-Kwan;Kim, Tae-Hyun;Wang, Wen;Yang, Sang-Sik;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1430-1435
    • /
    • 2007
  • We developed a 440MHz surface acoustic wave (SAW) microsensor integrated with pressure-temperature sensors and ID tag. Two piezoelectric substrates were bonded, in which ${\sim}150\;{\mu}m$ cavity was structured. Four sides were completely sealed by JSR photoresist (PR). Pressure sensor was placed on the top substrate, whereas ill tag and temperature sensor were placed on the bottom substrate. Using network analyzer, the developed microsensor was wirelessly tested. Sharp reflection peaks with high S/N ratio, small signal attenuation, and small spurious peaks were observed. All the reflection peaks were well matched with the coupling of mode (COM) simulation results. With a 10mW RF power from the network analyzer, a ${\sim}1$ meter readout distance was observed. Eight sharp ON reflection peaks were observed for ID tag. Temperature sensor was characterized from $20^{\circ}C$ to $200^{\circ}C$. A large phase shift per unit temperature change was observed. The evaluated sensitivity was ${\sim}10^{\circ}/^{\circ}C$.

Utilizing Noise Mapping in Environmental Impact Assessment in a Downtown Redevelopment Area (도심지 재개발사업 환경영향평가시 소음지도 적용방안에 관한 연구)

  • Lee, Shi-Won;Park, Young-Min;Choi, Jin-Kwon;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1311-1317
    • /
    • 2005
  • In environmental Impact assessment, noise impact assessment usually consists of three stages-surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of a project. The distance-attenuation relation of a point source, which has been used to predict the noise level due to its simplicity does not consider complex acoustic phenomena like multi-reflection, -diffraction and -absorption due to complex topographic configuration of buildings and terrains. For the consideration of such physical complexities. a noise mapping tool is adopted to produce a series of noise maps, which are those for the present, tot the works of construction and for the future. For accurate noise mapping, acoustical and topographic Information is used. Standard sound power levels and directivities of various construction equipments are need and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.

A microstrip folded compact wideband band-pass filter with wide upper stopband

  • Hoseini, Seyyed Mojtaba Seyyed Najjar;Zaker, Reza;Monfaredi, Khalil
    • ETRI Journal
    • /
    • v.43 no.6
    • /
    • pp.957-965
    • /
    • 2021
  • A miniaturized wideband band-pass filter with a 3-dB fractional bandwidth of 109.3% (1.53 GHz to 5.22 GHz), high out-of-band attenuation greater than 25 dB, and wide upper stopband up to 14 GHz is proposed. The design consists of a dual-composite right/left handed resonator, embedded open-circuited stub, and a pair of quarter-wavelength short-circuited stubs. These elements are coupled in the near distance to form a miniature filter with a compact occupied area of 0.21 λg×0.19 λg (≈ 0.013 cm2). The optimized filter has multitransmission poles in the passband, substantially improving the return loss and insertion loss characteristics. The behavior of the passband and stopband is verified against the results of a lumped element model and matrix analysis with a full-wave moment-based analysis and actual measurements. The results of this verification and a comparison with the performance of filters in other references indicate that the proposed filter is very efficient and applicable to compact microwave systems.

A Review of Current Clinical Research on Herbal Monotherapy for Coronavirus Disease-19 (COVID-19)

  • Jee Won Shon;Do Kyung Han;Won Gun An
    • The Journal of Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.193-207
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the effectiveness and safety of traditional herbal medicine as a stand-alone treatment group through major English databases due to the lack of RCTs in Korea, and to provide a review of the herbal interventions used. Methods: Using four databases (Pubmed, EMBASE, OASIS, RISS), combination of words such as "Coronavirus" "RCT" "Herb" "Decoction" "TCM" were used. RCTs using herbal medicines to treat coronavirus were searched. Final 4 studies were selected by two authors according to inclusion and exclusion criteria. Results: A total of 1,435 patients were studied. The Chinese herbs used in the treatment group were Shengmai Yin, JingYinGuBiao granules, Jinhua Qinggan granules, and Bufei Huoxue capsules. The intervention group showed greater attenuation of pneumonia lesions on CT. Also, improvement in 6-min walk distance (6MWD), and negative conversion rate in treatment group were reported. Furthermore, scores on the Fatigue Assessment Inventory (FAI) were lower in the herbal group than in the placebo group. The median time to recovery of COVID-19 related symptoms was shorter in TCM group compared to the control group. Reported adverse effects were diarrhea, liver dysfunction, and excessive menstruation, and two papers did not mention side effects in detail. Conclusion: Herbal medicine alone can increase the conversion rate of viral negativity and relieve COVID-19 related symptoms without significant adverse effects.

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF

Study on the Relations to Estimate Instrumental Seismic Intensities for the Moderate Earthquakes in South Korea (국내 중규모 지진에 대한 계측진도 추정식 연구)

  • Yun, Kwan-Hee;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.323-332
    • /
    • 2018
  • Recent two moderate earthquakes (2016 $M_w=5.4$ Gyeongju and 2017 $M_w=5.5$ Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above V to the insufficient data previously accumulated from the MMI regions limited up to IV. The MMI intensity regions of V and VI was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and 'DYFI (Did You Feel It)' MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above V were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=V and VI and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs from I to VI. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI. $MMI=2.36{\times}log_{10}(PGA(gal))+1.44$ ($I{\leq}MMI$$MMI=2.44{\times}log_{10}(PGV(kine))+4.86$ ($I{\leq}MMI$$MMI=2.59{\times}log_{10}(BSPGA(gal{\cdot}sec))-1.02$ ($I{\leq}MMI$