• Title/Summary/Keyword: distance P.D

Search Result 372, Processing Time 0.03 seconds

A Syndrome-distribution decoding MOLS L$_{p}$ codes

  • Hahn, S.;Kim, D.G.;Kim, Y.S.
    • Communications of Mathematical Education
    • /
    • v.6
    • /
    • pp.371-381
    • /
    • 1997
  • Let p be an odd prime number. We introduce simple and useful decoding algorithm for orthogonal Latin square codes of order p. Let H be the parity check matrix of orthogonal Latin square code. For any x ${\in}$ GF(p)$^{n}$, we call xH$^{T}$ the syndrome of x. This method is based on the syndrome decoding for linear codes. In L$_{p}$, we need to find the first and the second coordinates of codeword in order to correct the errored received vector.

  • PDF

Implementation of Stereoscopic 3D Video Player System Having Less Visual Fatigue and Its Computational Complexity Analysis for Real-Time Processing (시청피로 저감형 S3D 영상 재생 시스템 구현 및 실시간 처리를 위한 알고리즘 연산량 분석)

  • Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2865-2874
    • /
    • 2013
  • Recently, most of movies top-ranked in the box office are screening in Stereoscopic 3D, and the world's leading electronics companies such as Samsung and LG are getting the hots for 3DTV sales. However, each person has different binocular disparity and different viewing distance, and thus he or she feels the severe visual fatigue and headaches if he or she is watching 3D content with the same binocular disparity, which is very different from things he or she feels in the real world. To solve this problem, this paper proposes and implement a 3D rendering system that correct the disparity of 3D content by reflecting binocular distance and viewing distance. Then, the computational complexity is analyzed. Optical-flow and Warping algorithms turn out to consume 732 seconds and 5.7 seconds per frame, respectively. Therefore, a dedicated chip-set for both blocks is strongly required for real-time HD 3D display.

Power Input of Pitched and Double-Stage Paddle Impeller in a Agitated Vessel (교반조에서 경사 및 2단 Impeller의 교반소요동력에 관한 연구)

  • Lee, Young-Sei;Kim, Moon-Kap;Kim, Jong-Shik
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.18-25
    • /
    • 1996
  • Power input in stirred vessel is especially important in the design of mixers, as well as the evaluation of mixing processes. A type of baffles in mechanically agitated vessels and power employed are major factors that determine the stirring efficiency in a large scale, multi-step processes. In the present study, power input in the totally baffled agitated vesseles was compared systematically in connection with several previous studies and adequate power input correlation was found to be : $Np_{(pitch)}=({\theta}/90^{\circ})Np_{(90^{\circ})}$ Power number correlation was dependent upon the distance of among the impeller in the agitated vesseles, as follows : $$Np=7.09(n_p)^{0.7}(\frac{b_(double)}{d})(\frac{H}{D})^{0.18}$$, $${n_p}^{0.7}(\frac{b_{(double)}}d)$$<2 $$Np=8.73\{(n_p)^{0.7}(\frac{b_{(double)}}{d})\}^{0.7}(\frac{H}{D})^{0.18}$$, $${n_p}^{0.7}(\frac{b_{(double)}}d)$$>2.

  • PDF

ON SENDOV'S CONJECTURE ABOUT CRITICAL POINTS OF A POLYNOMIAL

  • Nazir, Ishfaq;Mir, Mohammad Ibrahim;Wani, Irfan Ahmad
    • Korean Journal of Mathematics
    • /
    • v.29 no.4
    • /
    • pp.825-831
    • /
    • 2021
  • The derivative of a polynomial p(z) of degree n, with respect to point α is defined by Dαp(z) = np(z) + (α - z)p'(z). Let p(z) be a polynomial having all its zeros in the unit disk |z| ≤ 1. The Sendov conjecture asserts that if all the zeros of a polynomial p(z) lie in the closed unit disk, then there must be a zero of p'(z) within unit distance of each zero. In this paper, we obtain certain results concerning the location of the zeros of Dαp(z) with respect to a specific zero of p(z) and a stronger result than Sendov conjecture is obtained. Further, a result is obtained for zeros of higher derivatives of polynomials having multiple roots.

FLUORESCENCE QUENCHING OF BBOT BY ANILINE IN DIFFERENT ORGANIC SOLVENTS

  • Kadadevarmath, J.S.;Giraddi, T.P.;Chikkur, G.C.
    • Journal of Photoscience
    • /
    • v.4 no.3
    • /
    • pp.105-112
    • /
    • 1997
  • The fluorescence quenching of 2, 5-di-(5-tert-butyl-2-benzoxazolyl)-thiophene (BBOT) by aniline in five different solvents namely heptane, hexane, cyclohexane, dioxane and acetonitrile has been carried out at room temperature with a view to understand the quenching mechanisms. The experimental results show positive deviation in the Stern-Volmer plots in all the solvents. In order to interpret these results we have invoked the Ground state complex and sphere of action static quenching models. Using these models various rate parameters have been determined. The magnitudes of these parameters suggest that sphere of action static quenching model agrees well with the experimental results. Hence this positive deviation is attributed to the static and dynamic quenching. Further, with the use of Finite Sink approximation model, it was possible to check these bimolecular reactions as diffusion-limited and to estimate independently distance parameter R$^1$ and mutual diffusion coefficient D. Finally an attempt has been made to correlate the values of R$^1$ and D with the values of the encounter distance R and the mutual diffusion coefficient D determined using the Edward's empirical relation and Stokes-Einstein relation.

  • PDF

The Prediction of Injection Distances for the Minimization of the Pressure Drop by Empirical Static Model in a Pulse Air Jet Bag Filter (충격기류식 여과집진기에서 경험모델을 이용한 최소압력손실의 분사거리 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.25-34
    • /
    • 2011
  • The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (${\Delta}P_{initial}$) and the dust mass number term($N_{dust}=\frac{{\omega}_0{\nu}_f}{P_{pulse}t}$), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance ($K_d$), one of the empirical static model parameters got the minimum value at d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

Photosystem I and II Reaction Centers in a New Type Oxygenic Photosynthesis of Acaryochloris marina Based on Chlorophyll d: Studies of Delayed Fluorescence and Triplet State ESR

  • Itoh, Shigeru;Fukushima, Yoshimasa;Itoh, Kunihiro;Maeda, Masanori;Mino, Hiroyuki;Kumazaki, Shigeichi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.70-73
    • /
    • 2002
  • A cyanobacteria-like organism Aaryochloris marina performs oxygenic photosynthesis with near far-red light by the use of chlorophyll d. Reaction center chlorophyll (Chl) of Photosystem (PS) II of A. marina was studied by analysis of millisecond-delayed fluorescence. Delayed fluorescence is emitted by Chi d indicating efficient energy transfer between antenna Chi d molecules and the unknown primary electron donor of PS II. P740 a reaction center Chl of PS I of A. marina is shown to give a dimer type cation, and triplet state with a D value of 245xlO$\^$-4/ cm$\^$-l/ in contrast to the 280-290 xlO$\^$-4/cm$\^$-l/ values of P700 suggesting triplet spins interacting at a 5% larger distance in P740 than in P700.

  • PDF

A Study on Reading Pupillary and Distance Between Optical Centers suitable for Korean (한국인 체형에 적합한 근용안경의 광학중심간 거리에 대한 연구)

  • Youk, Do-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.37-45
    • /
    • 2003
  • This study investigated that total 1071 reading glasses wearers (male 432, female 639) without any eye disease or deformation in eyelid, orbit, eyeball (over 50 years old), were tested. Reading pupillary distance of 524 (male 202, female 322) of 1071 were examined and reading glasses power was examined for all 1071 patients. As a result of average reading diopters analysis by sex. male had S+2.34Dptr, female had S+2.23Dptr in average and male had a little more average power than female by 0.11Dptr. However, the difference was not much enough and by aging accommodation reduction changes were applied to both male and female. After dividing ready-made reading glasses on sale in optical shops into 5 groups by F.P.D. the average D.B.O.C(distance between optical centers) of each 5 group was examined (1st group 64.04 mm, 2nd group 66.96 mm, 3rd group 68.28 mm, 1th group 62.03 mm, 5th group 72.00 mm : the average of all groups was 66.96 mm : each group included 3 random samples : 195 ready-made reading glasses were measured), and compared with the average reading P.D of males and females (male 60.04 mm, female 58.23 mm). The result showed D.B.O.C of ready-made reading glasses on sale was bigger than the average reading P.D of them. The result reviewed the average range for male was $0.23{\Delta}(minimum){\sim}5.06{\Delta}(maximum)$, and for female was $0.46{\Delta}{\sim}5.79{\Delta}$. In conclusion when wearing ready-made reading glasses, female got more effected by average $0.45{\Delta}$ because reading P.D of female was smaller than that of male.

  • PDF

The Load Distribution Characteristics of Pile Group under Lateral Loading (수평력을 받는 무리말뚝의 하중분담특성)

  • Ahn, Byungchul;Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.17-22
    • /
    • 2010
  • This paper analyzed the characteristics of p-multiplier and the load distribution of H-pile group installed in weathered soil under horizontal loading. The results of this study conducted in pile arrangement ($2{\times}3$, $3{\times}3$), the pile center to center spacing (2D, 4D, 6D), and soil density (relative density: 40%, 80%) were drawn as follows. As to the average horizontal loading applied to each pile in pile groups, the fewer number of piles was, the larger average horizontal resistance became. As the result of analysis on p-y curves of single piles and pile groups according to the pile distance and the soil density, as the pile spacing was increased from 2D to 6D, the interaction coefficients of pile group showed 0.85~0.94 (piles in the front row), 0.57~0.79 (piles in the middle row), and 0.60~0.71 (piles in the rear row) in the loose ground and showed 0.76~0.82 (piles in the front row), 0.58~0.73 (piles in the middle row), and 0.53~0.70 (piles in the rear row) in the dense ground. As above, the wider pile distance was, the larger interaction coefficient value was shown among piles. In addition, piles in the front row showed bigger interaction coefficients than that of piles in the middle and back row.