• Title/Summary/Keyword: dissipation test

Search Result 752, Processing Time 0.028 seconds

Formulation of Cyclic Plasticity Model and FE Analysis for SM490 TMC (SM490 TMC 강재의 반복소성모델의 정식화 및 유한요소해석)

  • 장갑철;장경호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.84-89
    • /
    • 2004
  • In this paper, cyclic plasticity model of SM490 TMC was formulated by basing on monotonic loading test and cyclic loading test. For exact description of cyclic performance and plastic deformation capacity of steel member using SM490 TMC, formulated cyclic plasticity model and finite deformation theory were applied to 3-dimensional elastic-plastic FE analysis. Cyclic plastic behavior of pipe-section steel column using SM490 TMC was clarified by carrying out numerical analysis. Also, in order to clarifying seismic performance of pipe-section steel column using SM490 TMC, analysis results were compared with analysis results of pipe-section steel column using SM490. A comparison of analysis results shows that SM490 TMC pipe-section steel column has a better cyclic performance for strength and energy dissipation than SM490 pipe-section steel column under cyclic loading

  • PDF

An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns (프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구)

  • Choi, Seung-Won;Shin, Hyun-Mok;Lee, Jae-Hoon;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Compressibility Characteristics of Pusan Clays (부산점토의 압축특성)

  • ;;Pham Huy Giao
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.361-368
    • /
    • 2000
  • In other to examine the compressibility characteristics of cohesive soils in the mouth of the Nakdong river, the oedometer tests were peformed on undisturbed and reconstituted samples obtained by continuous boring typically at 3 different sites. It is meaningful to compare the consolidation behavior of natural clays with a reference state because the natural clays are depending on the stress history, sedimentary environment and geological history. In this study, the insitu state of the Pusan clays was investigated using the concepts of ISL(Nagaraj, 2000) and ICL and SCL(Burland, 1990). And for the purpose of confirming the existence of the underconsolidated clays, a standpipe type piezometer test and a dissipation test by piezocone were performed at their sites. Consequently, the Pusan clays were evaluated as normally consolidated clays.

  • PDF

Seismic performances of steel reinforced concrete bridge piers

  • Deng, Jiangdong;Liu, Airong;Yu, Qicai;Peng, Guoxing
    • Steel and Composite Structures
    • /
    • v.21 no.3
    • /
    • pp.661-677
    • /
    • 2016
  • The quasi static test of the steel reinforced concrete (SRC) bridge piers and rigid frame arch bridge structure with SRC piers was conducted in the laboratory, and the seismic performance of SRC piers was compared with that of reinforced concrete (RC) bridge piers. In the test, the failure process, the failure mechanism, hysteretic curves, skeleton curves, ductility coefficient, stiffness degradation curves and the energy dissipation curves were analyzed. According to the $M-{\Phi}$ relationship of fiber section, the three-wire type theoretical skeleton curve of the lateral force and the pier top displacement was proposed, and the theoretical skeleton curves are well consistent with the experimental curves. Based on the theoretical model, the effects of the concrete strength, axial compression ratio, slenderness ratio, reinforcement ratio, and the stiffness ratio of arch to pier on the skeleton curve were analyzed.

Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames

  • Zahrai, Seyed Mehdi;Jalali, Meysam
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.1-21
    • /
    • 2014
  • Knee Braced Frame (KBF) is a special form of ductile eccentrically braced frame having a diagonal brace connected to a knee element, as a hysteretic damper, instead of beam-column joint. This paper first presents an experimental investigation on cyclic performance of two knee braced single span one-story frame specimens. The general test arrangement, specimen details, and most relevant results (failure modes and hysteretic curves) are explained. Some indexes to assess the seismic performance of KBFs, including ductility; response reduction factor and energy dissipation capabilities are also subsequently discussed. Experimental results indicate that the maximum equivalent damping ratios achieved by test frames are 21.8 and 23% for the specimens, prior to failure. Finally, a simplified analytical model is derived to predict the bilinear behavior of the KBFs. Acceptable conformity between analytical and experimental results proves the accuracy of the proposed model.

The study for performance of isolators supported floating slab track (플로팅 슬래브궤도용 방진재의 성능에 관한 연구)

  • Kim, Jin-Ho;Cha, Hyo-Jung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.569-574
    • /
    • 2007
  • The paper presents an application of the model to a practical problem of train-induced vibrations. The aim of this study is to vertify for performance of isolators which was developed in KRRI supported floating slab track. Laboratory tests on developed isolations show that the energy dissipation, under cyclic loading of constant amplitude, can be suitably represented by a combination of a viscous and a hysteretic damping. Also, other tests for structural performance are carried out, such as elastic material test, compression test and so on. The specimen, $400{\times}400{\times}300mm$, is placed between two stiff steel plates designed to uniformly distribute the compression stress on the surface.

  • PDF

Post-Cyclic Deformation Behavior of Non-Liquefied Weathered Soils (반복재하후 미액상화 풍화토 지반의 변형 거동)

  • 최연수;정충기
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.485-492
    • /
    • 2001
  • Weathered soil is one of the most representative soils in Korea. In this study, a series of cyclic triaxial tests was carried out to predict the post-cyclic deformation behavior of weathered soils in case of non-liquefaction. Excess pore pressure response during cyclic loading and volumetric strain during the dissipation of excess pore pressure were measured varying the confining pressure, relative density and cyclic stress ratio. Based on the test results, it Is found that the modified excess pore pressure ratio, excess pore pressure ratio normalized by cyclic stress ratio, is uniquely correlated with the number of cycles irrespective of confining pressure and cyclic stress ratio. Using the newly proposed MEPPR(modified excess pore pressure ratio) concept, it is possible to easily evaluate the excess pore pressure and the settlement of weathered soils due to cyclic loading by greatly reduced number of tests. It is also verified that the reconsolidation volumetric strain is independent of the way how the excess pore pressure was generated.

  • PDF

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

Design of Vertical Slit type perforated Breakwater at Busan New Marine Town (부산 해상신도시에 있어서의 종 Slit형 유공방파제 설계)

  • 김재경;주희찬;안익성
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1992.08a
    • /
    • pp.58-63
    • /
    • 1992
  • In addition to the traditional breakwater faculty, multipurpose breakwater of vertical slit type perforated breakwater was planed and designed using the idea of waterfront and wave dissipation of breakwater. As a result of experimental test, the good hydraulic characteristics was confirmed by comparison of traditional structure, and in order to the field application the section was improved on the test of result.

  • PDF

A Case Study on the Suction Drain Method for Soft Ground Improvement (연약지반 개량을 위한 석션드레인공법의 적용 사례)

  • Kim, Do-Hyung;Kim, Byung-Il;Han, Sang-Jae;Lee, Jae-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.743-749
    • /
    • 2009
  • In this study, the field test for suction drain method which does not require a surcharge load and a sealing sheet was performed at west seashore's site constructed by the dredged and reclaimed clay. The improvements of soft ground by suction drain method was analyzed by the results of real-time field measurement, SPT(Standard Penetration Test) and laboratory tests. The results indicated that the soft ground improvement is effective the vertical drain method used with vacuum pressure rather than surcharge load with considering settlements, dissipation of pore water pressure and shear strength.

  • PDF