• Title/Summary/Keyword: dissipation factor

Search Result 396, Processing Time 0.023 seconds

Inverter Air-conditioner Power System with Low Power Dissipation Type using Micro-controller

  • Mun, Sang-Pil;Shu, Ki-Young;Kim, Ju-Yong;Kim, Kwang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.492-496
    • /
    • 2004
  • When using a conventional power factor correction circuit, a comparatively huge capacitor is used to boost-up output voltage. It has a large amount of harmonic distortion in the input current waveform. To improve the input current waveform of diode rectifiers, we propose a new operating principle for the power factor correction circuit. Due to the fact that the proposed circuit uses smaller ones and a smaller reactor, the output voltage increases and obtains higher input current waveforms. These are suitable for the harmonics guidelines. The proposed circuit is able to obtain higher power factor and efficiency. Also, it has reduced switching loss and held over-shooting by using an inverter of eliminated dead-time HPWM that has non-linear impedance circuits to make up diodes, capacitance and a reactor. We compared the conventional PWM inverter and proposed HPWM inverters and found that a high input power factor of 97[%] and an efficiency of 98[%] were also obtained.

  • PDF

Residue Dissipation Patterns of Indoxacarb and Pymetrozine in Broccoli under Greenhouse Conditions (시설재배 브로콜리 중 Indoxacarb 및 Pymetrozine의 잔류 소실특성)

  • Yang, Seung-Hyun;Lee, Jae-In;Choi, Hoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.75-82
    • /
    • 2020
  • BACKGROUND: This study was carried out to establish pre-harvest residue limits (PHRLs) of indoxacarb and pymetrozine in broccoli under greenhouse conditions, based on dissipation patterns and biological half-lives of pesticides during 10 days after application. METHODS AND RESULTS: The field studies were conducted in two different greenhouse, located in Chungju-si (Field 1) and Gunsan-si (Field 2). Samples were collected at 0, 1, 2, 3, 5, 7 and 10 days after spraying pesticide suspension. The analytical methods for indoxacarb and pymetrozine using HPLC-DAD were validated by recoveries ranging of 94.3-105.4% and 81.8-96.0%, respectively, and MLOQ (Method Limit of Quantification) of 0.05 mg/kg. Biological half-lives of indoxacarb and pymetrozine were 2.9 and 3.2-3.8 days in broccoli, respectively. The lower 95% confidence intervals of dissipation rate constant of indoxacarb were determined as 0.1508 (Field 1) and 0.2017 (Field 2), whereas those of pymetrozine were calculated as 0.1489 (Field 1) and 0.1577 (Field 2). CONCLUSION: The significant differences were not observed between the dissipation rates of indoxacarb and pymetrozine in broccoli. The major factor affecting residue dissipation was the dilution effect by fast growth. The PHRLs for 10 days prior to harvest were recommended as 30.06 (Field 1) and 18.07 (Field 2) mg/kg for indoxacarb, and 4.84 (Field 1) and 4.43 (Field 2) mg/kg for pymetrozine, respectively.

Readeveloping Turbulent Boundary Layer after Separation-Reattachment(I) (박리-재부착 이후의 재발달 난류경계층 I)

  • 백세진;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.780-788
    • /
    • 1989
  • An experimental study has been performed to investigate the process from nonequilibrium state to equilibrium state in redeveloping turbulent boundary layer beyond separation-reattachment using pitot tube and hot-wire anemometer. The model sued in the experiment has the form of a backward facing step which is assembled by a two-dimensional 4:1 half elipse and a plate. Measurements are carried out up to a distance of about 50 step height downstream of the step, where the reattachment observed at about x/h=6.5. The profiles of the shape factor H the Clauser parameter G and the coefficient of friction $C^{f}$ exhibited the characteristics similar to those of the equilibrium turbulent boundary layer from x/h=25, and the profiles of the trubulent quantities did from x/h=35. However, the wake region of the boundary layer does not seem to recover the equilibrium turbulent boundary layer even at x/h=50. By considering the distributions of the intermittency factor it has been noted that the turbulence structure changes gradually from a mixing layer to a turbulent boundary layer along downstream direction after reattachment. This becomes clearer as we analyse the one-dimensional energy spectra and the dissipation energy spectra which are measured and caculated at various downstream positions after the backward facing step.p.

The Behavior Variation of the Ion Viscosity and the Compressive Strength of the Seawater and Freshwater Flooded Chlorosulfonated Polyethylene After Accelerated Thermally Ageing (가속 열화 후 해수 담수 침지된 Chlorosulfonated Polyethylene의 이온 점도와 압축 강도의 특성 변화)

  • Hong, So Young;Kim, Min Ju;Jeong, Eun Mi;Kim, Jin Pyo;Shin, Yong Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.490-495
    • /
    • 2019
  • This study performs the thermal aging of chlorosulfonated polyethylene (CSPE) for 807.36 and 1,614.48 hours at $110^{\circ}C$, which is equivalent to 40 and 80 years of aging at $50^{\circ}C$ in nuclear power plants, respectively. Flat-type CSPEs were soaked in seawater for five days and then dried for five days at room temperature. Furthermore, the soaked CSPEs were cleaned for 5 days with fresh water and dried for 1,100 days at room temperature. Through this process, the log IV of the CSPEs decreases, whereas the dissipation factor of the CSPEs increases as thermally accelerated aged years increase at the measured frequency. Although the phase degree of the response voltage versus excitation voltage of the CSPEs increases, that of the response current versus excitation voltage decreases with the thermally accelerated aging. The thermal conductivity of the CSPEs increases slightly, but the thermal diffusivity does not vary with the thermally accelerated aged year increase. The displacement of the compressive strength of the CSPEs decreases gradually as the thermally accelerated aged years increase.

Evaluation of seismic reliability and multi level response reduction factor (R factor) for eccentric braced frames with vertical links

  • Mohsenian, Vahid;Mortezaei, Alireza
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.537-549
    • /
    • 2018
  • Using vertical links in eccentric braced frames is one of the best passive structural control approaches due to its effectiveness and practicality advantages. However, in spite of the subject importance there are limited studies which evaluate the seismic reliability and response reduction factor (R-factor) in this system. Therefore, the present study has been conducted to improve the current understanding about failure mechanism in the structural systems equipped with vertical links. For this purpose, following definition of demand and capacity response reduction factors, these parameters are computed for three different buildings (4, 8 and 12 stories) equipped with this system. In this regards, pushover and incremental dynamic analysis have been employed, and seismic reliability as well as multi-level response reduction factor according to the seismic demand and capacity of the frames have been derived. Based on the results, this system demonstrates high ductility and seismic energy dissipation capacity, and using the response reduction factor as high as 8 also provides acceptable reliability for the frame in the moderate and high earthquake intensities. This system can be used in original buildings as lateral load resisting system in addition to seismic rehabilitation of the existing buildings.

Optimum Design of Multi-Stacking Current Lead Using HTS Tapes (고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계)

  • 설승윤;김민수;나필선
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF

The Dielectric and Piezoelectric Properties of (Pb1-1.5xLax)(Ti1-yMny) System ((Pb1-1.5xLax)(Ti1-yMny)O3계의 유전 및 압전성질)

  • 맹성재;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.4
    • /
    • pp.321-328
    • /
    • 1988
  • The sintering phenomena, electrical resistivity, dielectric and piezoelectric properties of lead titanate ceramics modified by the partial substitution of La for Pb and Mn for Ti, (Pb1-1.5xLax)(Ti1-yMny)O3 ceramics, have been investigated. In (Pb1-1.5xLax)(Ti1-yMny)O3 system, with increasing lanthanum content, the realtive bulk density increased, but the Curie point and tetragonality (c/a) decreased. The tetragonal-to-cubic phase transition boundary existed in the range of 0.20

  • PDF

Stability Analysis ofn HTS Current Lead with Constant Safety Factor (안전율이 일정한 초전도 전류도입선의 안정성해석)

  • Seol, Seoung-Yun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.15-19
    • /
    • 2000
  • The stability of variable cross-sectional area HTS current lead is considered. The cross-sectional area is varied to have a constant safety factor which is defined as the ratio of operating current and critical current of superconductor. As the constant area HTS lead, the variable cross-sectional area HTS lead also has three steady states above the bifurcation point and only one steady state below the bifurcation point. The temperature profiles and current sharing ratios for each steady state are calculated. The heat dissipation into cryogenic system for super-conducting, intermediate, and upper states are compared. For Bi-2333 sheathed with silver-gold alloy 2m length of current lead, and the maximum temperature of upper state seems to be burn-out free below 5m length.

  • PDF

Modeling and Analysis of Three Phase PWM Converter (3상 PWM 컨버터의 모델링 및 해석)

  • 조국춘;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF

Effects of Seawater & Freshwater Soaking on the Cure Properties of Accelerated Thermally Aged CSPE (가속열화 된 CSPE의 경화특성에 미치는 해수 담수 침지의 영향)

  • Shin, Yong-Deok;Lee, Jeong-U
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.819-824
    • /
    • 2016
  • The accelerated thermal aging of CSPE (chlorosulfonated polyethylene) was carried out for 33.64 and 67.27 days at 110[$^{\circ}C$], equivalent to 40 and 80 years of aging at 50[$^{\circ}C$], respectively. These samples were referred to as CSPE-0y, CSPE-40y and CSPE-80y, respectively. As the accelerated thermally aged years of the CSPE increase, the insulation resistance[$\Omega$] at 20[Hz], 500[Hz], and 2[KHz], and the percent elongation [%EL] of the CSPE decrease. However, the dissipation factor($tan{\delta}$) at 20[Hz], 500[Hz], and 2[KHz], the apparent density[$g/cm^3$], the glass transition temperature and the melting temperature of the CSPE were increased. The period of time that the voltage has to be applied until electric breakdown of the CSPE-0y is longer than that of the CSPE-40y, and the CSPE-80y, but the dielectric strength of the CSPE-80y is lower than that of the CSPE-0y and the CSPE-40y. The differential temperatures after the AC and DC voltages are applied to CSPE-0y, CSPE-40y and CSPE-80y are 0.026~0.028[$^{\circ}C$], 0.030~0.042[$^{\circ}C$], 0.018~0.045[$^{\circ}C$], respectively. The variations of temperature for the AC voltage are higher than those for the DC voltage when an AC voltage is applied to CSPE-0y, CSPE-40y and CSPE-80y. It is found that the dielectric loss owing to the dissipation factor[$tan{\delta}$] is related to the electric dipole conduction current. It is ascertained that the ionic (electron or hole) leakage current is increased by the separation of the branch chain of CSPE polymer from the main chain of the polyethylene as a result of thermal stress due to accelerated thermal aging as well as by conducting ions such as $Na^+$, $Cl^-$, $Mg^{2+}$, $SO_4^{2-}$, $Ca^{2+}$ and $K^+$ after seawater soaking.