DOI QR코드

DOI QR Code

가속 열화 후 해수 담수 침지된 Chlorosulfonated Polyethylene의 이온 점도와 압축 강도의 특성 변화

The Behavior Variation of the Ion Viscosity and the Compressive Strength of the Seawater and Freshwater Flooded Chlorosulfonated Polyethylene After Accelerated Thermally Ageing

  • 홍소영 ((주)연진S-Tech 부설 재료물성분석기술연구소) ;
  • 김민주 ((주)연진S-Tech 부설 재료물성분석기술연구소) ;
  • 정은미 ((주)연진S-Tech 부설 재료물성분석기술연구소) ;
  • 김진표 ((주)연진S-Tech 부설 재료물성분석기술연구소) ;
  • 신용덕 ((주)연진S-Tech 부설 재료물성분석기술연구소)
  • Received : 2019.07.26
  • Accepted : 2019.08.22
  • Published : 2019.11.01

Abstract

This study performs the thermal aging of chlorosulfonated polyethylene (CSPE) for 807.36 and 1,614.48 hours at $110^{\circ}C$, which is equivalent to 40 and 80 years of aging at $50^{\circ}C$ in nuclear power plants, respectively. Flat-type CSPEs were soaked in seawater for five days and then dried for five days at room temperature. Furthermore, the soaked CSPEs were cleaned for 5 days with fresh water and dried for 1,100 days at room temperature. Through this process, the log IV of the CSPEs decreases, whereas the dissipation factor of the CSPEs increases as thermally accelerated aged years increase at the measured frequency. Although the phase degree of the response voltage versus excitation voltage of the CSPEs increases, that of the response current versus excitation voltage decreases with the thermally accelerated aging. The thermal conductivity of the CSPEs increases slightly, but the thermal diffusivity does not vary with the thermally accelerated aged year increase. The displacement of the compressive strength of the CSPEs decreases gradually as the thermally accelerated aged years increase.

Keywords

References

  1. G. Janowska, A. Kucharska, W. M. Rzymski, and A. Kasiczak, J. Therm. Anal. Calorim., 102, 1019 (2010). [DOI: https://doi.org/10.1007/s10973-009-0622-2]
  2. Korea Advanced Institute of Science and Technology, Department of Nuclear and Quantum Engineering, "Accident of Fukushima NPPs in Japan: Outcomes and impact, and lessons learned", (Interim Report), 2011.
  3. U.S. Nuclear Regulatory Commission / Regulatory Guide 1.218 "Condition Monitoring Techniques for Electric Cables used in Nuclear Power Plants", Office of Nuclear Regulatory Research, Apr. 2012.
  4. H. L. Lee, The Handbook of Dielectric Analysis and Cure Monitoring, Lambient Technologies L.L.C., (2014) pp. 13-16, pp. 31-32.
  5. Lambient Technologies L.L.C., AN11-LT-451 and LCR Meter Comparison and LT-4203 Parallel Plate Test Fixture, Version 1.0, http://www.lambient.com (2014).
  6. http://www.yeonjin.com
  7. INTERNATIONAL STANDARD ISO 22007-2, "Plastics-Determination of thermal conductivity and thermal diffusivity-Part 2: Transient plane heat source (hot disc) method", First edition 8. December. 2008.
  8. V. Tanrattanakul and A. Petchkaew, J. Appl. Polym. Sci., 99, 127 (2006). [DOI: https://doi.org/10.1002/app.22500]
  9. A. Roychoudhury and P. P. De, J. Appl. Polym. Sci., 63, 1761 (1997). [DOI: https://doi.org/10.1002/(SICI)1097-4628 (19970328)63:13<1761::AID-APP8>3.0.CO;2-E]