• 제목/요약/키워드: displacement current method

검색결과 311건 처리시간 0.03초

열자격 변위 전류법에 의한 인지질막의 구조 연구 (A study on the structural of phospholipid membranes by thermally stimulated displacement current method)

  • 이경섭;김우연;권영수;이준응;강도열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권7호
    • /
    • pp.696-701
    • /
    • 1996
  • In this study, deposited lipid membranes on the electrode and detected thermally stimulated displacement current generated from it. The researchers examined displacement current of electric conduction organic monolayer generated due to orient change of monolayers alkylchain and changed of dipole moment vertical component due to thermally stimulated. We paid attention to the phase transition temperature obtained by the thermally stimulated displacement current of lipid membrane layers this time. We detected the thermally stimulated displacement current peak of layers. From above results the transition temperature dilauroylphosphatidylcholine layers is about 43.deg. C. This study also compared above results with those obtained by differential thermal analysis method.

  • PDF

철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$ (Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.

전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장 (Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

변위전류법에 의한 지질단분자막의 전기특성에 관한 연구 (A study on the electrical properties of lipid monolayers by displacement current method)

  • 이경섭;권영수
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.450-454
    • /
    • 1996
  • Maxwell-Displacement-Current(MDC) measuring technique has been applied to the study of monolayers of Dilauroylphosphatidylcholine (L-.alpha.-DLPC) and Dimyristoylphosphatidylcholine (L-.alpha.-DMPC). The displacement current was generated from monolayers on a water surface by monolayer compression. Displacement current was generated when the area per molecule was about 250.angs.$^{2}$, 280.angs.$^{2}$. Displacement current was generated in the gas state, gas/liquid state, and liquid state in the course of monolayer compression. The orientational change of molecules in monolayers was discussed on the basis of the MDCs obtained. Finally, we measured differential thermal analysis of sample.

  • PDF

PBLG의 자격반응에 관한 연구 (A Study on the Stimulus Reaction of PBLG)

  • 김병근;장헌;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.719-722
    • /
    • 2002
  • The Displacement current measurement system used in this experiment because detecting the dynamic behavior of monolayers at the air-water interface is possible. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is placed in the water. PBLG phase transformation measured by Maxwell-displacement-current-measurement method in surface of the water. Measured (surface pressure, displacement current and dipole moment) of monolayers of PBLG on the water surface. We measured displacement current that occur when changed temperature. Could know that displacement current is proportional in increase of temperature and great as experiment result.

  • PDF

전류변성기 비교기의 비오차 및 위상오차 평가기술 (Evaluation Technique for Ratio Error and Phase Displacement of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.437-443
    • /
    • 2008
  • We have developed an evaluation technique for both ratio error and phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique to equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors (or phase displacements) in the CT comparator. Thus we can evaluate ratio errors and phase displacement of CT comparator by comparing the calculated and measured ratio errors (or phase displacements). The method was applied to CT comparator under test with the ratio errors and phase displacement ranges of $0{\sim}{\pm}10%$ and $0{\sim}{\pm}7.5$ crad, respectively. Finally we have compared the ratio error and phase displacement of the CT comparator obtained in this method with specifications of two companies.

PBDG의 자격반응과 물성에 관한 연구 (A Study on Stimulus reaction and Physical Properties of PBDG)

  • 장헌;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1047-1049
    • /
    • 2001
  • The displacemant current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is placed in the water. With Maxwell-displacement-current-measuring method, the phase transitions of Poly-${\gamma}$ -benzyl D-glutamate(PBDG) on a water surface were detected. Measured surface pressure, displacement current and dipole moment of monolayers of PBDG on the water surface. We measured analyzed displacement current that occur when differed temperature. Could know that displacement current is proportional in increase of temperature and great as experiment result.

  • PDF

전류변성기의 비오차와 위상오차의 절대 평가 기술 (Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers)

  • 김윤형;정재갑;한상길;구경완;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

변위전류법에 의한 지질 단분자막의 $\pi$-A특성 ($\pi$-A properties of phospholipid monolayers by Maxwell-displacement-current-measuring technique)

  • 이경섭;전동규;권영수;국상훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 춘계학술대회 논문집
    • /
    • pp.120-123
    • /
    • 1995
  • Maxwell-Displacement-Currnt-Measuring Technique(MDCM) is a simple system for displacement current measuring which consist with two electrodes to the electrometer, With this method, the displacement current flow only when the electric flux density change by the displacement of molecules or charge particles of membrance on the water surface. Thus, It is Possible to detect dynamic behavior of molecules of membrane without any electrical contact with molecule membrane. In this paper, We measure surface pressure, displacement current and dipole moment of phospholipid monolayers on the wafer surface with applied pressure by MDCM and We measured DTA(differential thermal analysis).

  • PDF

전류변성기 비교기의 위상오차 평가 기술 (Evaluation technique for phase displacement of current transformer comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2032-2033
    • /
    • 2008
  • We have developed an evaluation technique for phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured phase displacement in the CT comparator. Thus we can evaluate phase displacement of CT comparator by comparing the calculated and measured phase displacement. The method was applied to CT comparator under test with the phase displacement ranges of $0{\sim}{\pm}7.5$ crad. Finally we have compared the phase displacement of the CT comparator under test theoretically obtained in this method with the specification.

  • PDF