• Title/Summary/Keyword: dislocations

Search Result 420, Processing Time 0.028 seconds

Fractures and Dislocations of the Cervicothoracic Junction

  • Kim, Jin-Wook;Jeong, Ju-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.211-215
    • /
    • 2007
  • Cervicothoracic junction instability should be stabilized with the circumferential fusion. In addition, cervicothoracic junctional area should be examined carefully in acute traumatic injury not only to confirm hidden lesions but also to make the proper surgical plans. Here, three patients who underwent cervicothoracic arthrodesis at our institution are presented with a review of literature.

A Study on the Lubrication Characteristics of Liquid Crystals (액정의 윤활특성에 관한 연구)

  • 임윤철;민지홍
    • Tribology and Lubricants
    • /
    • v.8 no.1
    • /
    • pp.30-37
    • /
    • 1992
  • The displacement and pressure field of liquid crystals are analyzed numerically and compared with classical Reynolds theory. A plane slider bearing is employed as a simple example considering elasticity, permeability and splay effect which are the inherent characteristics of layered liquid crystals. Due to the geometric constraint of thin wedge and the strong anchoring behavior of the liquid crystals dislocations are inevitable. A finite element method is used to solve five coupled nonlinear equations. The load characteristics based on the pressure distribution along the gap shows that the liquid crystals can carry large load compared to the conventional lubricants.

Superfine Flip-Chip Interconnections in 20-$\mu\textrm{m}$-pitch

  • Bonkohara, Manabu
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.09a
    • /
    • pp.183-199
    • /
    • 2002
  • Reliability.The reliability strongly depended on the CTE of underfill resin..The fractured portion was identical with the maximum plastic equivalent strain..1 % or less value of the maximum plastic equivalent strain certified more than 1000 cycle of TCT life. UFB.Bonding accuracy was confirmed within2$2{\mu}{\textrm}{m}$..The fundamental bondability of UFB was confirmed with no damage around aluminum pads. Some dislocations and vacancies were observed at the interface, however, the atomic level bonding was confirmed. CBB.Dry process was applied to UBM removal.

  • PDF

Effect of Tempering Temperatures on Tensile Properties in a Low Carbon Steel (저탄소강에서 템퍼링 온도가 인장변형에 미치는 영향)

  • 이영범;김대성;남원종
    • Transactions of Materials Processing
    • /
    • v.12 no.8
    • /
    • pp.744-749
    • /
    • 2003
  • The effect of tempering temperatures on microstructures and mechanical properties was studied in a low carbon steel. The disappearance of continuous yielding and the formation of an extended region in engineering stress-strain curves at tempering temperatures ranging from 673 to 873K was caused by the reduction of mobile dislocations during tempering and dynamic recovery during tensile deformation. In addition, the occurrence of discontinuous yielding in the sample treated at the tempering temperatures above 923K was attributed to the formation of new strain-free polygonal ferrite grain.

A framework for geometrically non-linear gradient extended crystal plasticity coupled to heat conduction and damage

  • Ekh, Magnus;Bargmann, Swantje
    • Multiscale and Multiphysics Mechanics
    • /
    • v.1 no.2
    • /
    • pp.171-188
    • /
    • 2016
  • Gradient enhanced theories of crystal plasticity enjoy great research interest. The focus of this work is on thermodynamically consistent modeling of grain size dependent hardening effects. In this contribution, we develop a model framework for damage coupled to gradient enhanced crystal thermoplasticity. The damage initiation is directly linked to the accumulated plastic slip. The theoretical setting is that of finite strains. Numerical results on single-crystalline metal showing the development of damage conclude the paper.

Features of Epitaxial Garnet Films for an Atomic Traps Technique

  • Berzhansky, V.N.;Vishnevskii, V.G.;Nedviga, A.S.;Nesteruk, A.G.
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.108-113
    • /
    • 2009
  • High-coercive garnet films have certain parameters suitable for creating reconfigurable magnetic atomic chips with visible geometry. However, the inner stresses and morphological properties, namely, networks of dislocations, layering and surface relief, and dependence of coercivity on thickness must be taken into account. Select features of films important for atomic trap creation have been studied experimentally and the supposed traps concept provided.

Eponymous terms in acromioclavicular joint surgery

  • Daniel E. Verstift;Jelle Heisen;Matthijs P. Somford;Michel P.J. van den Bekerom
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.2
    • /
    • pp.229-236
    • /
    • 2024
  • Eponymization serves as a means of paying tribute to individuals who have made significant contributions to our culture. Each eponym is often linked with a story for everyone to discover. To aid in the retention of these stories, this review offers readers an overview of the individuals behind the eponymous terms, as well as their original descriptions, within the context of acromioclavicular joint pathology and orthopaedic surgery.

Practical Construction of Tsunami Inundation Map to Link Disaster Forecast/Warning and Prevention Systems (예경보와 방재시스템의 연계를 위한 지진해일 범람도의 실용적 작성)

  • Choi, Jun-Woo;Kim, Kyung-Hee;Jeon, Young-Joon;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.194-202
    • /
    • 2008
  • In general, forecast tsunami heights announced for tsunami warning are computed by using a linear tsunami model with coarse grids which leads the underestimation of inundation area. Thus, an accurate tsunami inundation map corresponding the forecast tsunami height is needed for an emergency evacuation plan. A practical way to construct a relatively accurate tsunami inundation map was proposed in this study for the quantitative forecast of inundation area. This procedure can be introduced as in the followings: The fault dislocations of potential tsunami sources generating a specific tsunami height near an interested area are found by using a linear tsunami model. Based on these fault dislocations, maximum inundation envelops of the interested area are computed and illustrated by using nonlinear inundation numerical model. In this study, the tsunami inundation map for Imwon area was constructed according to 11 potential tsunami sources, and the validity of this process was examined.

Clinical and Radiological Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocations and Distal Clavicle Fractures

  • Oh, Joo Han;Min, Seunggi;Jung, Jae Wook;Kim, Hee-June;Kim, Jae Yoon;Chung, Seok Won;Kim, Joon Yub;Yoon, Jong Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the clinical outcomes and complications of hook plate fixation in acromioclavicular (AC) joint dislocations and distal clavicle fractures. Methods: We retrospectively reviewed a series of 60 consecutive patients with hook plate fixation for AC joint dislocation (group I) and distal clavicle fracture (group II). Groups I and II had 39 and 21 patients, respectively. Clinical results were evaluated using the pain visual analogue scale (VAS), simple shoulder test, and Constant-Murley scores. In addition, subacromial erosion and stiffness were evaluated as complications. Results: At the removal, the pain VAS was $2.69{\pm}1.30$ and $4.10{\pm}2.14$ in groups I and II, respectively, which were significantly different (p=0.003). The simple shoulder test score was $9.59{\pm}1.60$ and $7.81{\pm}2.67$ in groups I and II, respectively, which were also significantly different (p=0.002). Subacromial erosion was significantly more frequent in group II (14/21 patients, 66.7%) than in group I (15/39 patients, 38.5%) (p=0.037), and stiffness was also higher in group II (17/21 patients, 81.0%) than in group I (22/39 patients, 56.4%), but it was not significant. Conclusions: Hook plate fixation showed good clinical and functional results for the treatment of acute unstable AC joint dislocation and distal clavicle fracture. But, in distal clavicle fractures, there are more subacromial erosion and stiffness compare with acute unstable AC joint dislocation.