• Title/Summary/Keyword: disinfection

Search Result 946, Processing Time 0.027 seconds

Disinfection Efficiency of the Waste Stabilization Ponds Coupled with Aquatic Plant Ponds (산화지와 수생식물 처리지를 결합한 통합 처리 시스템의 살균효율에 관한 연구)

  • Kim, Youngchul;Jeong, Ha-Young;Lee, Rae-Bum;Lim, Gyeongeun
    • Journal of Wetlands Research
    • /
    • v.4 no.2
    • /
    • pp.23-41
    • /
    • 2002
  • In this paper, changes of the coliform bacteria were investigated when aquatic plant pond was used for separating algal particles from waste stabilization ponds(WSPs). Three different types of integrated natural systems were operated. It was found that there were no significant interferences for the disinfection efficiency of two integrated systems (WSPs coupled with water hyacinth ponds) used for treating domestic sewage and upgrading the secondary effluent as well. However, when constructed wetland (CW) was combined with the shallow algal ponds and used for the secondary effluent, it seriously interfered with the disinfection efficiency due to the regrowth and/or after-growth of the coliform bacteria, which can readily metabolize the amino acids and sugars leached from plants. In order to find out the primary disinfection parameters, several sets of the batch test were run. It was found that sunlight is the most predominant factor for the coliform decay. During the night, algal toxicity partly supports the decay but during the day, deteriorates it by attenuating the sunlight. The pH in the range of 4 to 10 did not affect the decay in the dark.

  • PDF

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Establishment of optimal disinfection condition of weak acid hypochlorous solution for prevention of avian influenza and foot-and-mouth disease virus transmission (조류 인플루엔자와 구제역 바이러스 차단방역을 위한 미산성 차아염소산수의 소독 조건)

  • Kim, Jin-Yoon;Yun, Dong-Sik;Lee, Haw-Yong;Jeong, Woo-Seog;Park, Seung-Chun
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.2
    • /
    • pp.101-104
    • /
    • 2019
  • This study examined the disinfection conditions (exposure time, 0-30 min; exposure temperature, $4^{\circ}C-65^{\circ}C$) of hypochlorous acid water (HOCl) in automobile disinfection equipment. The study tested poliovirus type 1 (PV1), low pathogenic avian influenza virus (AIV, H9N2), and foot and mouth disease virus (FMDV, O type). As a result, the PV1 and FMD viruses were inactivated easily (virus titer 4 log value) by HOCl (> 100 ppm) but the AIV required higher exposure temperatures (> $55^{\circ}C$). In conclusion, the exposure temperature and time are important factors in deactivating AIV and FMDV.

The disinfection effect of UV-C and calcium hypochlorite to shrimp farm instruments contaminated with EHP (Enterocytozoon hepatopenaei) (EHP (Enterocytozoon hepatopenaei)에 오염된 사육기구에 대한 UV-C와 차아염소산칼슘의 소독 효과)

  • Ji Min Ryu;Eul Bit Noh;Bo Seong Kim
    • Journal of fish pathology
    • /
    • v.37 no.1
    • /
    • pp.139-145
    • /
    • 2024
  • In this study, nylon mash and silicone tube mainly used as shrimp farm equipment were contaminated with Enterocytozoon hepatopenaei (EHP) which is the cause of Hepatopancreatic microsporidiosis (HPM), and were treated with calcium hypochlorite or UV-C disinfection methods for EHP eradication. As a result, similar with the control group (not disinfected), EHP was detected on the nested PCR until the 10 days in the UV-C single treated group. On the other hand, EHP was not detected from 7 days in calcium hypochlorite single treated group (total concentration 200 ppm as available chlorine), and combination of calcium hypochlorite and UV-C treated group revealed no detection of EHP from 3 days. It is appropriate that treated with UV-C and calcium hypochlorite for 3 days or single treated with calcium hypochlorite for 7 days to eradicate EHP on contaminated instrument used in shrimp farms. In contrast, disinfection effect of only using UV-C is very low.

Simulation Method for the Flowing Water Purification with UV Lamp (자외선램프을 이용한 유수처리장치 설계 시뮬레이션)

  • Jeong, Byeong-Ho;Lee, Kang-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2009
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. In this paper, it describe the how to design optimal ultraviolet disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

A Study on Inactivation of E.coli Through 368.6[nm] UV Irradiation Lamp (368.6[nm]를 최대방사 파장으로 포함한 자외선램프에 의한 대장균(E.coli)의 불활성화에 관한 연구)

  • Chang, In-Soung;Lee, Ju-Hun;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.1-5
    • /
    • 2009
  • Disinfection using UV irradiation has been considered to an alternative for chlorination because it does not suffer from disinfection byproducts problem. The aim of this study was to verify if UV irradiation with 368.6[nm] wavelength has a potential to be used a efficient disinfection. UV irradiation was given for 60 minutes to E. coli. which was used as a model microorganism. Remarkable decrease in number of microorganism was not observed for initial 30 minutes, however, 83.3[%] of disinfection efficiency was achieved after 30 minutes of irradiation. Inactivation constant, k was determined to 0.00868[$cm^2$]/([$mW{\cdot}s$]) using kinetic approach.

The Effect of Disinfection and the MRSA Isolation from Hand Disinfectant in ICU Nurses (중환자실 간호사들의 손 소독제에 따른 소독효과 및 MRSA 분리)

  • Park, Sun-Nam;Rhyu, Kyung-Hwa;Jeong, Jeong-Im;Park, Ok-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.3
    • /
    • pp.359-367
    • /
    • 2006
  • Purpose: This study was a within subject repeated pretest-posttest design done to compare the effect of disinfection and the degree of MRSA(Methicillin- resistant staphylococcus aureus) isolation from hand disinfectant in ICU nurses. Method: Out of the total internal medicine/surgery ICU nurses at a university hospital in Seoul, 29 female nurses who were participating in direct patient care were participants in this study. After collection of samples, Staphylococcus aureus and MRSA were isolated from the palms, nails and nasal cavities of the nurses according to disinfectants (soap and beta-scrub). Results: The effect of disinfection was greater in the beta-scrub group than in the soap group, and the effect of disinfection on palms was higher in the beta-scrub group than in the soap group. As for the degree of MRSA isolation, there was more isolation in palms in the soap group than in the beta-scrub group but there was no difference in the degree of MRSA isolation from the hand disinfectant in nails and nasal cavities. Conclusion: Beta-scrub showed a superior prolonged effect against transient bacteria compared with soap. Further, to reduce MRSA infection, we recommend interventions focused on these aspects.

  • PDF

Distribution of Antibiotic Resistant Microbes in Aquaculture Effluent and Disinfection by Electron Beam Irradiation (양식장 배출수중의 항생제 내성균 분포 및 전자빔 살균처리)

  • Jang, Eun-Hee;Lim, Seung-Joo;Kim, Tak-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.492-500
    • /
    • 2011
  • Antibiotic resistant microbes were isolated in catfish, trout, eel and loach aquaculture effluent. The distribution of antibiotic resistant microbes in aquaculture effluent and the disinfection efficiency of antibiotic resistant microbes by electron beam irradiation were investigated. It was shown that the multi-drug resistant bacteria were Aeromonas sp., Citrobacter sp., Bacillus sp., Marinobacter sp., Pantoea sp., Pseudomonas sp. and Enterobacter sp. in aquaculture effluent. 41.7% of total strains showed the resistance against one antibiotic agent, and 58.3% of total strains showed the resistance against more than two antibiotics. It was evidently shown that the toxicity and physicochemical properties of antibiotics can be estimated using Quantitative Structure Analysis Relationship (QSAR). Electron beam irradiation was very effective for the disinfection of antibiotic resistant bacteria from aquaculture effluent, in which the disinfection efficiency was approximately 99.9% with electron beam of 1 kGy.

Inactivation Effect of Cryptosporidium by Ozone and UV (Ozone과 UV를 이용한 Cryptosporidium의 불활성화 효과)

  • Kim, Yun-Hee;Lee, Chul-Hee;Lee, Shun-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • The objective of this study was to investigate the inactivation characteristics of Cryptosporidium oocysts by ozone and UV and to suggest the better, disinfection method. The inactivation CT value of 1 log(90%) and 2 log(99%) in of one disinfection, which is an index of disinfection for inactivation effect by ozone, were respectively 5.77 $mg{\cdot}min/L$ and 21.30 $mg{\cdot}min/L$. The inactivation in UV disinfection was not affected by pHs(5, 7 and 9), low turbidity(5 and below NTU) and UV intensity(0.2 and 0.6 $mWs/cm^2$) but obviously decreased at high turbidity over 20 NTU. Therefore UV disinfection capacity can be obtained when a good turbidity removal in drinking water treatment process is achieved. And if oocysts is exposed by high UV over 0.6 mWs/cm2 during enough time, the better inactivation effect will be obtained.

Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments (실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측)

  • Cho, Min;Chung, Hyenmi;Kim, Reeho;Shon, Jinsik;Park, Sangjung;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.