• Title/Summary/Keyword: discriminant validity

Search Result 391, Processing Time 0.022 seconds

Discriminant Validity of the Child Behavior Checklist for Ages 1.5-5 in Diagnosis of Autism Spectrum Disorder (자폐스펙트럼장애 진단에서 Child Behavior Checklist 1.5-5 유아 행동평가척도 부모용의 변별력)

  • Lee, Sun Hee;Ha, Eun Hye;Song, Dong-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2015
  • Objectives: The purpose of this study was to verify the validity and clinical cutoff score of the Child Behavior Checklist for ages 1.5-5 (CBCL 1.5-5) for diagnosis of autism spectrum disorder (ASD). Methods: 44 ASD infants and 100 normal infants participated. T-test, discriminant analysis, receiver operating characteristic (ROC) curve analysis, and odds ratio analysis were performed on the data. Results: Discriminant validity was confirmed by mean differences and discriminant analysis on the subscales of Withdrawn, Attention problems, Internalizing problems, Externalizing problems, Total problems, and all Diagnostic and Statistical Manual of Mental Disorders (DSM)-oriented scales between the two groups. ROC curve analysis showed that Withdrawn, Attention problems, Internalizing problems, Externalizing problems, Total problems, DSM pervasive developmental problems, DSM attention deficit/hyperactivity problems, and DSM oppositional defiant problems significantly predicted ASD infants compared to normal infants. In addition, the clinical cutoff score criteria adopted in the Korean CBCL 1.5-5 for subscales of Withdrawn, Attention problems, Internalizing problems, Externalizing problems, Total problems, DSM pervasive developmental problems, DSM attention deficit/hyperactivity problems, and DSM oppositional defiant problems were shown to be valid. Conclusion: The subscales of Withdrawn, Attention problems, Internalizing problems, Externalizing problems, Total problems, DSM pervasive developmental problems, DSM attention deficit/hyperactivity problems, and DSM oppositional defiant problems significantly discriminated for the diagnosis of ASD.

The Validity of Activity Participation Assessment for School-Age Children (학령기 아동을 위한 활동 참여 평가도구(Activity Participation Assessment)의 타당도 연구)

  • Kim, Se-Yun
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.17 no.1
    • /
    • pp.19-29
    • /
    • 2019
  • Objective : The aim of this study was to verify validity of the Activity Participation Assessment for school-age children. Methods : A questionnaire consisting of 30 items from the APA, 75 items from the PACS, and 55 items from the CAPE was administered to elementary school students. A total of 207 questionnaires were analyzed. Confirmatory factor analysis was performed to confirm the construct validity of the APA. Convergence validity and discriminant validity were verified with the average variance extracted (AVE) and the square of the correlation coefficient. The discriminant validity was the Pearson correlation coefficient of the APA, PACS, and CAPE. Results : The results of the analysis were as follows: 1) For construct validity, the goodness of fit of the modified hierarchical second-order factor model was found to be appropriate (p < .001), 2) For convergent validity, the AVE was higher than .50 for all latent variables, 3) For discriminant validity, the AVE of the latent variable was greater than the square of the correlation coefficient (0.239), 4) For concurrent validity, the correlation between the total sum of the APA and PACS scores showed a positive correlation in all domains, and the correlation coefficient ranged from .303 to .647 at a statistically significant level (p < .01), 5) The correlation coefficient between the total sum of the APA and CAPE scores was .490 for recreational activities, .329 for physical activities, .571 for social activities, .401 for skill-based activities, and .390 for self-improvement activities. All domains showed a positive correlation, and were statistically significant (p < .01). Conclusion : APA can be used as a valid assessment tool to measure the participation of school aged children.

Validity and Reliability of the Korean Version of Person-Centered Practice Inventory-Staff for Nurses (간호사 대상 한국어판 인간중심돌봄 측정도구의 타당도와 신뢰도)

  • Kim, Sohyun;Tak, Sunghee H
    • Journal of Korean Academy of Nursing
    • /
    • v.51 no.3
    • /
    • pp.363-379
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the validity and reliability of the Korean version of Person-Centered Practice Inventory-Staff (PCPI-S) for nurses. Methods: The English PCPI-S was translated into Korean with forward and backward translation. Data were collected from 338 nurses at one general hospital in Korea. Construct validity was evaluated with confirmatory factor analysis, convergent validity, and discriminant validity. Known-group validity was also evaluated. Cronbach's α was used to assess the reliability. Results: The PCPI-S Korean version consisted of 51 items in three areas: prerequisites, the care environment, and person-centered process. The comparative fit index (CFI) and values of person-centered care process were improved after engagement and having sympathetic presence items were combined as one component. The construct validity of PCPI-S Korean version was verified using four-factor structures (.05 < RMSEA < .10, AGFI > .70, CFI > .70, and AIC). The convergent validity and discriminant validity of the entire PCPI-S question were verified using a two-factor structures (AVE > .50, construct reliability > .70). There was an acceptable known-group validity with a significant correlation between the PCPI-S level and the degree of person-centered care awareness and education. Internal consistency was reliable with Cronbach's α .95. Conclusion: The Korean version of PCPI-S is valid and reliable. It can be used as a standardized Korean version of person-centered care measurement tool. Abbreviation: RMSEA = root mean square error of approximation; AGFI = adjusted goodness of fit index; AIC = Akaike information criterion; AVE = average variance extracted.

Study of the Validity Test on the Self-monitoring Scale for Primi-Gravida (초임부를 대상으로 한 자가검색도 척도의 타당도 비교)

  • Lee, Seon-Ah
    • Women's Health Nursing
    • /
    • v.4 no.2
    • /
    • pp.173-186
    • /
    • 1998
  • In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen (1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity was found in the previous research findings. It is also important to note that Snyder's self-monitoring scale, did not factor-load at over 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lack convergent validity as the sub-factors of the scale fail to prove its uni-dimensionality. The A self-monitoring scale not only fail to overcome the problems of Snyder's self-monitoring scale but even lost the attractiveness of the self-monitoring scale. In this study, it was also found that the A self-monitoring scale was not classified as hypothesized in either in a two or three-factor classification. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used but also has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study 1. was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were classified and loaded as expected. Reliability was also proven by checking Cronbach's alpha for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound ; however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original or the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over .30, too high for the two factors in the test results of factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Validity and Reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in Knee Osteoarthritis Patients (골관절염영향측정척도(AIMS-SF)의 타당도 및 신뢰도 - 일부 슬관절 골관절염 환자를 대상으로 -)

  • Yi, Seung-Ju;Nam, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.5
    • /
    • pp.29-41
    • /
    • 2007
  • Purpose: The aim of this study was to examine the validity and reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in patients with knee osteoarthritis(OA). Methods: The sample consisted of 62 patients who had received physical therapy at the physical therapy units of the Andong Medical Center, Sungso Hospital, Ahn Orthopedic Surgery Clinic, and St. Luke Clinic in Andong city in June 2006. Questionnaire on the AIMS-SF was recruited by 5 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, Pearson's relation coefficient. To explore construct validity we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. Results: 62 OA patients's an average $age{\pm}standard$ deviation was $53.8{\pm}14.4$ years (range: $40{\sim}81$ yr). The internal consistency reliability of 11 items, as estimated by Cronbach's ${\alpha}$ coefficient, was high ranging $0.60{\sim}0.78$ (except for 0.40 for mobility level and -0.48 for mood). The internal consistency reliability of item-each scale was also high $0.82{\sim}0.93$ (except for 0.48 for mood). Of 11 items, the item-discriminant validity on 6 items was high (${\alpha}$ coefficient range: $0.11{\sim}0.25$), however, others (0.57 for tension level, 0.48 for arthritis pain, 0.41 for walking and bending, and 0.40 for work) were a little low. The construct validity by factor analysis was a little low. Conclusion: In conclusion, the results reported here confirm the validity and reliability of the AIMS-SF in patients with OA of the knee. The Collection of information on health status using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

  • PDF

Validity and Reliability of the Korean Version of the Expanded Nursing Stress Scale (한국어판 간호사 직무 스트레스 측정도구의 타당도와 신뢰도 분석)

  • Kim, Kyoung Mi;Nam, Kyoung A;Lee, Eunhee;Jeong, Geum Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.21 no.5
    • /
    • pp.542-551
    • /
    • 2015
  • Purpose: This study was done to evaluate validity and reliability of the Korean version of the expanded nursing stress scale (ENSS). Methods: Forward-backward translation of ENSS from English to Korean was conducted. The translated instrument was pilot-tested and administrated to 285 nurses who worked in five general hospitals in Korea. Internal consistency reliability was assessed using Cronbach's ${\alpha}$ and composite reliability. Validity was evaluated through construct validity with confirmatory factor analysis, convergent and discriminant validity. Results: The Korean version of ENSS showed a reliable internal consistency with Cronbach's ${\alpha}$ .95 and composite reliability .99. Model fit indexes for 46 items were validated by confirmatory factor analysis(goodness of fit index .82, Tucker-Lewis index .92, root mean square error of approximation .04), indicating suitable construct validity. Factor loading of the 48 items (.47~.88) and average variance extracted out of nine factors (.52~.71.) indicated satisfactory convergent validity. Some values of square of the correlation coefficient between factors (.12~.89) were higher than average variance extracted values of each factor (.52~.71) so that it partly satisfied discriminant validity. Conclusion: Findings show that the Korean version ENSS has good reliability and suitable validity; therefore, can be used to assess and identify Korean nurses' job stress.

Validity and Reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-VA3.0 in Hip and Knee Osteoarthritis Patients (WOMAC-VA3.0의 타당도 및 신뢰도 -일부 슬관절 및 고관절 골관절염환자를 대상으로-)

  • Yi, Seung-Ju;Lee, Hyun-Ju;Woo, Young-Keun
    • Physical Therapy Korea
    • /
    • v.15 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The purpose of this study was to examine the validity and reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-VA3.0 in patients with hip and knee osteoarthritis (OA). The sample consisted of 301 patients who had received treatments at the physical therapy units of 5 medical institutions in Andong City in june 2006. Questionnaires on the WOMAC were recruited by 12 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency (Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, and Pearson's relation coefficient. To explore construct validity, we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. The average age of the patients was 62.1 years. All WOMAC subscales (pain, stiffness, and physical function) were internally consistent with Cronbach's coefficients of .81, .91, and .80, respectively. The internal consistency reliability of item-each scale were also internally consistent with Cronbach's coefficient of .89 (Pearson's correlation coefficient: .71~.84), .93 (.89~.91), and .96 (.67~.91), respectively. However, high correlation was found among 3 items (.66~.83, .66~.67, and .67~.83), so the item-discriminant validity was low (${\alpha}$ coefficient: .81, .91, .80, respectively). The construct validity by factor analysis was low because it was not consistent With WOMAC-VA3.0. In conclusion, the results reported here confirm the reliability of the WOMAC in patients with OA of the hip and knee. The collection of information on the hip and knee osteoarthritis using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

  • PDF

Development of the Korean Form of the Premonitory Urge for Tics Scale: A Reliability and Validity Study

  • Kim, Mira;Chung, Sang-Keun;Yang, Jong-Chul;Park, Jong-Il;Nam, Seok Hyun;Park, Tae Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.31 no.3
    • /
    • pp.146-153
    • /
    • 2020
  • Objectives: This study aimed to evaluate the reliability and validity of the Korean Form of the Premonitory Urge for Tics Scale (K-PUTS). Methods: Thirty-eight patients with Tourette's disorder who visited Jeonbuk National University Hospital were assessed with the K-PUTS. Together with the PUTS, the Yale Global Tic Severity Scale (YGTSS), the Children's Yale-Brown Obsessive Compulsive Scale (CY-BOCS), the attention-deficit/hyperactivity disorder (ADHD) rating scale (ARS), and the Adult ADHD Self-Report Scale (ASRS) were implemented to evaluate concurrent and discriminant validity. Results: The internal consistency of items on the PUTS was high, with a Cronbach's α of 0.79. The test-retest reliability of the PUTS, which was administered at 2 weeks to 2 months intervals, showed high reliability with a Pearson correlation coefficient of 0.60. There was a significant positive correlation between the overall PUTS score and the YGTSS score, showing concurrent validity. There was no correlation between the PUTS, CY-BOCS, and ASRS scores, demonstrating the discriminant validity of the PUTS. Factor analysis for construct validity revealed three factors: "presumed functional relationship between the tic and the urge to tic," "the quality of the premonitory urge," and "just right phenomena." Conclusion: The results of this study indicate that the K-PUTS is a reliable and valid scale for rating premonitory urge of tics.

Development of a Korean version of the Bereavement Care Confidence Scale (K-BCCS) (한국형 사별돌봄자신감 척도 개발)

  • Kwon, So-Hi;Kim, Young-Joo
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.27 no.2
    • /
    • pp.197-209
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the validity and reliability of the Korean Bereavement Care Confidence Scale (K-BCCS). Methods: The Perinatal Bereavement Care Confidence Scale (PBCCS) was translated into Korean according to an algorithm of cultural adaptation process and excluded six items which were specific to perinatal bereavement. A total of 229 clinical nurses participated in the study. Construct validity, convergent validity, discriminant validity, and group comparison validity were evaluated, and Cronbach's α was calculated to estimate the reliability of the K-BCCS. Results: The K-BCCS consisted of 31 items in 7 factors, including knowledge and skills for bereavement care (12 items), organizational support (6 items), awareness of the needs (3 items), interpersonal skills (3 items), workload influence (2 items), continuous education (2 items), and understanding the grief process (3 items). The factor loading of 31 items within the 7 factors ranged from .60 to .86. For the convergent validity, the construct reliability (CR) ranged from .74 to .94, and the average variance extracted (AVE) ranged from .49 to .73, which is considered acceptable. The discriminant validity showed that the AVEs of the subscales were greater than the square of the correlation coefficient r. The nurses who had experience providing bereavement care (t=4.94, p<.001) or had received bereavement education (t=6.64, p<.001) showed higher K-BCCS values those without experience. The Cronbach's α of 31 items was .93 and ranged from .60 to .94 per subscale. Conclusion: The K-BCCS is a valid and reliable tool for evaluating nurses' confidence in bereavement care.

The validity and reliability of the Korean version of the General Attitudes towards Artificial Intelligence Scale for nursing students (한국어판 간호대학생의 인공지능에 대한 태도 측정도구 신뢰도 및 타당도 검증)

  • Seo, Yon Hee;Ahn, Jung-Won
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.28 no.4
    • /
    • pp.357-367
    • /
    • 2022
  • Purpose: The aim of the study was to verify the validity and reliability of the Korean version of the General Attitudes towards Artificial Intelligence Scale (GAAIS-K) for nursing students. Methods: Data from 235 participants were collected from April 12 to April 26, 2022. A total of 230 participants' data were analyzed. The data were analyzed for content, discriminant, known-groups, and construct validity using content validity index, correlation coefficient, and confirmatory factor analyses. The reliability of the GAAIS-K was examined using internal consistency and test-retest analyses. Results: The expert-rated content validity index was ≥.80. The sub-scales of the GAAIS-K were moderately correlated with attitude toward accepting technology, indicative of its discriminant validity. The male students' positive attitude score was significantly higher than that of the female students, satisfying the known-groups validity. Cronbach's α for the scale was .86 (positive) and .74 (negative), and the intra-class correlation coefficient for the two-week test-retest reliability was .86 (positive) and .60 (negative). The scores for positive and negative attitudes were 3.68±0.46 and 3.05±0.55. Conclusion: This study shows that the GAAIS-K is a valid and reliable instrument for assessing nursing students. Additional research is recommended to continue the evaluation of the GAAIS-K with a focus on healthcare settings.