• 제목/요약/키워드: discrepancy

검색결과 1,885건 처리시간 0.026초

비대칭무게중심 물체의 동적 들기 작업시 좌.우 허리 근육의 EMG 진폭차이와 피로를 줄이기 위한 자세 연구 (Strategical Postures for Relieving EMG Amplitude Discrepancy on Bilateral Low Back Muscles and Total Low Back Muscle Fatigue while Lifting Asymmetric Load Dynamically)

  • 김선욱;한승조
    • 산업경영시스템학회지
    • /
    • 제35권3호
    • /
    • pp.103-109
    • /
    • 2012
  • The purpose of this paper is to suggest the strategical lifting postures able to alleviate imbalanced EMG amplitude leading to an increase in low back muscle fatigue while lifting asymmetric load dynamically. Eleven male subjects are required to lift symmetrically an external load with 15.8kg and load center of gravity (LCG) deviated 10cm to the right from the floor to the waist height at the speed of about 25cm/sec. The EMG amplitudes on bilateral low back muscles (Longissimus, Iliocostalis, and Multifidus) are recorded during 2sec and analyzed. Independent variables are trunk postures (No bending vs. Bending to the LCG) and feet placements (Parallel vs. Right foot in front of the other vs. Right foot behind the other). Dependent variables are EMG amplitude average on six muscles and the EMG amplitude difference between right and left muscle group. Results indicate the phenomenon showing an amplitude increase in the left muscle group is equal to an decrease in the right one is observed in dynamic as well as static lifts, bending the trunk to the LCG increases amplitude discrepancy more than no trunk bending, and the amplitude discrepancy in one foot ipsilateral to LCG in front of the other foot is lowest among other foot postures. As bilateral EMG amplitude discrepancy increases total low back muscle fatigue, the strategical combination of no trunk bending and one foot close to LCG in front of the other is recommended for preventing elevated incidence of low back pain (LBP).

비생리적인 최대교두감합위의 교합재구성을 통한 수정 (Prosthetic rehabilitation for a patient with CO-MI discrepancy)

  • 추승식;허윤혁;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.273-282
    • /
    • 2015
  • 중심위에서 벗어나 있는 최대교두감합위는 상하악 치아의 조기접촉 및 사면활주의 직접적인 원인이며, 악관절 내장증, 치아마모, 치주질환 등을 일으킬 수 있다. 그러므로 광범위한 보철수복이 필요한 환자에서 중심위와 최대교두감합위의 불일치가 존재하는 경우 반드시 이를 제거하여 생리적인 교합양식을 회복해야 한다. 본 증례의 환자는 초진 시 약 3.5 mm의 사면활주와 다수의 우식 및 중등도의 치주질환을 앓고 있었다. 보철수복을 통해 기능 및 심미성을 회복하는 동시에 중심위와 최대교두감합위를 일치시켜 사면활주를 제거하였으며, ARCUSdigma II와 경두개 방사선 사진을 이용하여 생리적인 위치로 수정된 하악위와 변화된 개폐구 경로를 관찰하였다.

골 연령이 미성숙한 골육종 환자에서 사지 보존술 후의 하지부동에 대한 고찰 (A Clinical Study of Leg Length Discrepancy after a Limb-Sparing Operation in a Skeletally-Immature Osteosarcoma Patient)

  • 김재도;문용식;이덕희;조명래
    • 대한골관절종양학회지
    • /
    • 제4권1호
    • /
    • pp.22-29
    • /
    • 1998
  • A limb-sparing operation has a definitive role in the treatment of osteosarcoma in the lower extremity of skeletally-immature patients. After a limb-sparing operation, leg length discrepancy remains as a major disability that should be corrected. This study was designed to suggest methods of tumor resection and proper timing of leg length equalization in skeletally immature osteosarcoma patients. From September 1990 to January 1998, we reviewed eight osteosarcoma patients in an immature skeletal age. There were 4 males and 4 females, and their mean duration of follow-up was 50.37 months (range : 25 to 88 months). Mean skeletal age was 8 years (range : 8 months to 11 years). The patients were classified according to the methods of tumor resection ; intercalary resection in 1 case, transepiphyseal resection in 1, intra-articular resection in 5, and extra-articular resection in 1. The results were as follows ; 1. The leg lengthening was begun when a patient's leg length discrepancy reached 4-5cm. 2. The age of final lengthening with permanent reconstruction was 14 years in males and 12 years in females (about 2 years before skeletal maturity). 3. When reconstruction was performed with a temporary spacer, the site of lengthening Was in the soft tissue, not in bone, and then a permanant reconstruction was done. 4. Reconstruction with a biologic spacer to preserve the joint function was a reasonable method for equalization of leg length. In conclusion, the appropriate choice of reconstructive method and the age at which to correct the leg length discrepancy in a skeletally-immature osteosarcoma patients are important factors for maintaining leg length at full maturity.

  • PDF

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

Discrepancy of the location of depression on the soft tissue and the bone in isolated zygomatic arch fracture

  • Yong Jig Lee;Dong Gil Han;Se Hun Kim;Jeong Su Shim;Sung-Eun Kim
    • 대한두개안면성형외과학회지
    • /
    • 제24권1호
    • /
    • pp.18-23
    • /
    • 2023
  • Background: When performing reduction of zygomatic arch fractures, locating the inward portion of the fracture can be difficult. Therefore, this study investigated the discrepancy between the locations of the depression on the soft tissue and bone and sought to identify how to determine the inward portion of the fracture on the patient's face. Methods: We conducted a retrospective review of chart with isolated zygomatic arch fractures of type V in the Nam and Jung classification from March 2013 to February 2022. For consistent measurements, a reference point (RP), at the intersection between a vertical line passing through the end point of the root of the ear helix in the patient's side-view photograph and a transverse line passing through the longest horizontal axis of the external meatus opening, was established. We then measured the distance between the RP and the soft tissue depression in a portrait and the bone depression on a computed tomography (CT) scan. The discrepancy between these distances was quantified. Results: Among the patients with isolated zygomatic arch fractures, only those with a fully visible ear on a side-view photograph were included. Twenty-four patients met the inclusion criteria. There were four types of discrepancies in the location of the soft tissue depression compared to the bone depression: type I, forward and upward discrepancy (7.45 and 3.28 mm), type II, backward and upward (4.29 and 4.21 mm), type III, forward and downward (10.06 and 5.15 mm), and type IV, backward and downward (2.61 and 3.27 mm). Conclusion: This study showed that discrepancy between the locations of the depressions on the soft tissue and bone exists in various directions. Therefore, applying the transverse and vertical distances measured from a bone image of the CT scan onto the patient's face at the indicated RP will be helpful for predicting the reduction location.

A Study on a Basis for the Selection of a Design for Quadratic Model Fits Fearing a Cubic Bias in Multilple Response Case

  • Bae, Wha-Soo
    • Journal of the Korean Statistical Society
    • /
    • 제24권1호
    • /
    • pp.31-44
    • /
    • 1995
  • In fitting a model, there always exists a discrepancy between the fitted model and the true functional relationship. In measuring this discrepancy, Box and Drapper (1959) used the criterion dividing the discrepancy into two parts which are the bias error part and the variance error one in single response case. In this paper, an optimum design which makes these two types of errors as small as possible is found by extending the Box and Drapper criterion to multiple response situation. Especially, a design is found to meat rotatability conditions when we fit a quadratic model to each response fearing cubic bias. Using the central composite design, an application of general results to a specific case is shown to help understanding the material.

  • PDF

입력 불일치 해소에 의한 개선형 무충돌전환 (An Improved Bumpless Transfer by Solving the Input Discrepancy Problem)

  • 김태신;양지혁;권태완;권오규
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.982-987
    • /
    • 2009
  • On the controller switching time, even though on-line/off-line controller outputs are the same, a problem which deteriorates the performance of bumpless transfer can happen in case that any discrepancy between the two controller inputs is transferred directly to the controller output. In this paper, we analyze the cause of that phenomenon in existing research results and propose a new method which improves that problem. In order to solve this problem, the off-line controller is augmented to an anti-windup structure and an improved bumpless transfer method is derived by using the changed input of the off-line controller instead of the plant input. We exemplify the performance of the proposed method by comparing with the performance of the existing method via numerical examples.

임상가를 위한 특집 1 - 성장기 아동에서 상하악 폭경 부조화와 하악과두의 비대칭 성장과의 관계 (The relationship between the transverse discrepancy of the jaws and asymmetric growth of the condyles in children)

  • 이지나
    • 대한치과의사협회지
    • /
    • 제51권6호
    • /
    • pp.302-312
    • /
    • 2013
  • It has been established that disk displacement of the temporomandibular joint(TMJ) can cause mandibular asymmetry in growing subjects. One of the causes of internal derangement of TMJ seems to be the result of poor positioning of the joint structure in unilateral cross bite, and the subsequent occlusal trauma transferred to the functioning unit of the mandible, the joint and disc. Transverse discrepancy of the maxillary and the mandibular posterior dentoalveolar units was often found in mandibular asymmetric subjects. Most of the asymmetry in growing subjects becomes worse with further growth if left untreated. However once sufficient posterior overjet is gained through orthodontic treatment, many cases have shown improvement in facial asymmetry. Furthermore, the position of condyles in computed tomogram(con-beam CT) changed from anatomically unfavorable position to more concentric position.

Numerical discrepancy between serial and MPI parallel computations

  • Lee, Sang Bong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권5호
    • /
    • pp.434-441
    • /
    • 2016
  • Numerical simulations of 1D Burgers equation and 2D sloshing problem were carried out to study numerical discrepancy between serial and parallel computations. The numerical domain was decomposed into 2 and 4 subdomains for parallel computations with message passing interface. The numerical solution of Burgers equation disclosed that fully explicit boundary conditions used on subdomains of parallel computation was responsible for the numerical discrepancy of transient solution between serial and parallel computations. Two dimensional sloshing problems in a rectangular domain were solved using OpenFOAM. After a lapse of initial transient time sloshing patterns of water were significantly different in serial and parallel computations although the same numerical conditions were given. Based on the histograms of pressure measured at two points near the wall the statistical characteristics of numerical solution was not affected by the number of subdomains as much as the transient solution was dependent on the number of subdomains.

The Effects of "Me-model" Body-size Discrepancy on Young Korean Consumer's Shopping Mood, Store Satisfaction, and Intention to Revisit Online Apparel Stores

  • Lee, Ji Young;Johnson, Kim K.P.
    • 한국의류학회지
    • /
    • 제36권12호
    • /
    • pp.1297-1309
    • /
    • 2012
  • This study examined the effects of "me-model" body-size discrepancy on consumer's shopping mood, store satisfaction, and intention to revisit two types of online apparel stores (one featuring thin models and one featuring average-sized models). A convenience sample of women (n = 528) participated. Structural equation modeling was used to analyze the data. Participants who were thinner or similar to the models indicated positive shopping moods, a high level of online store satisfaction, and intended to revisit the stores when compared to participants who were larger than the models. Participants preferred the 'average-sized' model. This preference was attributed to the familiarity of the model and ability to effectively evaluate merchandise. The results revealed how models can influence apparel consumers in an online context.