• Title/Summary/Keyword: disconnection

Search Result 409, Processing Time 0.03 seconds

Study on the Risk Analysis of Complex Electrical Fire by the Partial Disconnection and Tracking (반단선과 트래킹에 의한 복합적 전기화재의 위험성분석 연구)

  • Park, Sang-Min;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.111-118
    • /
    • 2017
  • The present paper is a study on the risk analysis of complex electrical fire by the partial disconnection and tracking. First, in order to analysis the single cause of electrical fire risk by the partial disconnection, the thermal characteristic has been measured by the change in the number of strands and the rated current of a wire. And then, in order to analysis the electrical fire risk by complex cause, an experiment on the accelerated tracking has been carried out in a condition of partial disconnection and confirmed the fire relation between partial disconnection and tracking. From the experiment, if the partial wire disconnection acts as a single cause, the existing thermal characteristics generated by the flowing current has appeared more clearly by the increase in the flowing current due to the complex action of tracking. Accordingly, the disconnection of strands has appeared by the complex cause due to the drastic temperature increase which was not generated in the single cause. Namely, it has been confirmed that if the partial disconnection and tracking act complexly rather than the risk of electrical fire by the existing partial disconnection, relatively its risk has been increased in large.

Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection (과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

The Server Disconnection Problem on a Ring Network (링 네트워크에서의 서버 단절문제에 대한 해법)

  • Myung, Young-Soo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.35 no.1
    • /
    • pp.87-91
    • /
    • 2009
  • In the server disconnection problem, a network with m servers and their users is given and an attacker is to destroy a set of edges to maximize his net gain defined as the total disconnected utilities of the users minus the total edge-destruction cost. The problem is known to be NP-hard. In this paper, we study the server disconnection problem restricted to a ring network. We present an efficient combinatorial algorithm that generates an optimal solution in polynomial time.

Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire (VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Park, Jong-Young;Park, Young-Ho;Lee, Hyung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire (배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

Design and implementation of ESD cable Disconnection Monitoring System (ESD 접지선 단선 모니터링 시스템 설계 및 구현)

  • Seong, Jung-Mo;Chung, Young-Suk;Park, Koo-Rack
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.77-82
    • /
    • 2017
  • In the splay manufacturing process, conveyor systems are widely used for conveying panels. In this conveyor, a large number of grounding lines are used in order to prevent a product failure due to static electricity. In many cases, the grounding line is disconnected due to the rotation of the transporting roller or curling, leading to product failure. In order to solve such a problem, there is a growing need for a system capable of detecting disconnection of a ground wire in real time. Therefore, in this paper, we propose a disconnection monitoring system of ESD (Electro-Static Discharge) ground wire caused by friction between the conveyor drive part and the panel. The proposed system is a monitoring system that can detect disconnection and disconnection of ground wire using ATmega 2560 and Wheatstone Bridge circuit. It can detect disconnection of ground wire immediately and can take measures to reduce the defect rate due to static electricity. The system proposed in this paper is expected to be applicable to the production and test equipments of all industries where the ground wire is used.

Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet (엠보싱 PVC 시트를 이용한 부분절연(部分絶緣) 블록형 옥상(屋上) 비노출 복합방수(複合防水)공법 개발(開發)에 관(關)한 연구(硏究))

  • Wi, Tae-Hwan;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

The Mediating Effect of Defense Mechanism in the Relation between Disconnection and rejection Schema and Mental Health (단절 및 거절 도식과 정신건강 간의 관계에서 방어기제의 매개효과)

  • KIM, Haeng-Shin;SEO, Su-Gyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.3
    • /
    • pp.656-671
    • /
    • 2015
  • The purpose of the present study is to examine relationships between disconnection and rejection schema, defense mechanism, and mental health in college students using structural equation modeling. The present study suggested a proposed model in which defense mechanism exerted a full mediating effect on the relation between disconnection and rejection schema and mental health. Goodness of fit tests were used to compare the proposed model against competing models. The subjects consisted of 304 college students. They completed the Young Schema Questionnaire(YSQ-SF), the Defense Style Questionnaire(DSQ), and the Mental Health Scale. The results showed that the second model had a better goodness of fit. Based on these findings, it is suggested that psychological interventions for mental health in college students should consider strategies to use more flexible and more adaptive defense mechanism style.

Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet (엠보싱 PVC 시트를 이용한 부분절연 블록형 옥상 비노출 복합방수공법 개발에 관한 연구)

  • 위태환;강효진;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

From Resection to Disconnection for Seizure Control in Pediatric Epilepsy Children

  • Hwang, Jun Kyu;Kim, Dong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.3
    • /
    • pp.336-343
    • /
    • 2019
  • Epilepsy surgery revealed dramatically improved seizure outcomes over medical therapy in drug-resistant epilepsy patients. Children with epilepsy, however, have multiple epileptic focuses which require multilobar resection for better seizure outcome. Multilobar resection has not only the several severe surgical complications, such as hydrocephalus and shunt-related craniosynostosis, due to intracranial volume reduction. Isolation method (disconnection surgery) was progressively studied over epileptic focus removal (resective surgery) for seizure control. This concept was first introduced for functional hemispherotomy, and its primary principle is to preserve the vital vascularized brain that is functionally disconnected from the contralateral healthy brain. Currently in most epilepsy centers, the predominant disconnection surgical methods, including functional hemispherotomy, are continually being refined and are showing excellent results. They allow the functional isolation of the hemisphere or multi-lobe, affected by severe epilepsy. This review describes recent findings concerning the indication, surgical technique, seizure outcome and complications in several disconnection surgeries including the functional hemispherotomy for refractory pediatric epilepsy.