• Title/Summary/Keyword: discharge-supply system

Search Result 229, Processing Time 0.034 seconds

A Study of the Current Collection Characteristics Measurement Methodology for a High-Speed Train (고속열차 전기적 이선 특성 측정 방안 연구)

  • Cho, Hong-Shik;Han, In-Su;Lee, Tae-Hyung;Kim, Seok-Won;Kim, Young-Guk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3052-3058
    • /
    • 2011
  • A high-speed train is the system that the electric power is supplied through the overhead contact line and drives motors. In this case that the de-wiring beteen the overhead contact line and the pantograph of a high-speed train, the occasion that smooth power supply is not accomplished occurs sometimes. If the de-wiring occurs, the arc discharge may damage the overhead contact line or the pantograph, and the falling-off in power quality may cause the damage and malfunctioning of motor block. This paper presents the methodology that the arc discharge by de-wring between overhead line and pantograph is discriminated through measuring the PT and CT in the vehicle, and measures the current collection characteristics for a high speed train.

  • PDF

A Study on the Supply Gas Temperature Characteristics of Silent Discharge Type Ozonizer by Applying Radio Frequency Voltage (고주파 전압인가에 의한 무성방전형 오존발생기의 원료가스 온도특성에 관한 연구)

  • 이상근;전병준;박용권;박원주;이광식;권혁한;송현직;박중협
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.46-54
    • /
    • 2001
  • In this paper, a co-axial cylinder type ozonizer using silent discharge applying radio frequency voltage known as an ozone generation was designed and fabricated. A cooling system was installed to investigate the characteristics of ozone generation in accordance with temperature change of the supplied gas known as an important factor. The characteristics of ozone generation were investigated in accordance with the change of cooling temperature.

  • PDF

Modeling and Controller Design of an Automotive HID Lamp Ballast (자동차 헤드라이트용 고압 방전등 안정기 시스템의 모델링 및 제어기 설계)

  • Lee, In-Gyu;Choe, Seong-Jin;Lee, Gyu-Chan;Jo, Bo-Hyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.545-550
    • /
    • 2000
  • This paper presents design and analysis of an HID lamp ballast for a fast turn on characteristics and stable operation. It produces a high open circuit voltage for the ignition and it is controlled to supply effectively the power required to shorten the warm-up period after the breakdown. The lamp modeling by empirical data is presented. It is very effective in the designing of the control loop in the steady-state operating region. A stable operation of the lamp power regulation in the steady state is achieved, which is crucial for the long life time and constant light output. Stability analysis of the system is performed and the results are verified through various simulation results and the hardware experiments.

  • PDF

A study of the output waveform of solid-state laser of multi-discharge method by various switching control (다수 스위칭 제어를 통한 Multi-Discharge방식의 고체레이저 출력파형 연구)

  • Kwak, S.Y.;Kim, S.G.;Hong, J.H.;Noh, K.K.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1852-1854
    • /
    • 2003
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing. In order to make various pulse shapes with variable pulse length and high duty cycle, We have fabricated the power supply consisting 6 SCRs and the Pulse Forming Network(PFN) with the precise delay time control. So our control system has three switching circuits, 3 mesh PFN, and simmer circuit. In addition, we have designed and fabricated the PIC one-chip microprocessor(16F877) to control the delay time of sequential switching.

  • PDF

The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter (계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계)

  • Koh, Kwang-Soo;Oh, Pil-Kyoung;Kim, Hee-Jung;Kim, Young-Min
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

Daily Variation of Size-Fractionated Chlorophyll a Concentrations and Water Conditions Associated with Freshwater Discharge during Summer in the Yeongsan River Estuary (영산강 하구의 하계 담수 방류와 연관된 크기별 Chlorophyll a와 수환경의 일간 변동)

  • Kim, Sehee;Shin, Yongsik
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.72-80
    • /
    • 2020
  • A sea dike in the Yeongsan River estuary was constructed in 1981 to supply water and reclaim tidal flats for agriculture, separating the estuary into the freshwater and seawater zones. However, the sluice gates are frequently opened and freshwater is discharged in summer when more rainfall is recorded than other seasons, then converting the estuary to brackish water system. In this study, the direct effect of freshwater discharge was investigated by monitoring daily variation in water properties and phytoplankton size structure before and after the freshwater discharge events from 2013 to 2015. Freshwater discharge resulted in a sharp decrease in salinity and dissolved oxygen (DO) at surface water whereas it increased the turbidity of water column. However, salinity did not decrease sharply in 2014 when freshwater was discharged one day before the monitoring and salinity remained low prior to the monitoring. Levels of nutrients especially dissolved inorganic nitrogen (DIN) increased after the discharge and this contributed to potential limitation of nutrients such as P or Si rather than N in the estuary. Freshwater discharge also caused the changes in phytoplankton biomass (chlorophyll a) and size structure although their responses were different between years. The changes may affect growth of grazers and thus structure of marine food web by alternating food availability in the Yeongsan River estuary.

Analysis of Agricultural Water Supply System at the Dongjin-River Basin (동진강 유역의 농업용수 급수체계 분석)

  • Choi, Jin-Kyu;Son, Jae-Gwon;Kim, Young-Joo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • This study was investigated agricultural water supply system of major agricultural waterway for Gimje canal, Jeongeup canal, Dongjin river conduit of Dongjin river basin. Furthermore, this result will be used for water resources and agricultural demand in Saemangeum reclaimed arable land. Annual precipitation for 5 years in Dongjin river basin was 1,311.7mm. The average discharges in Dongjin river basin was $1,390{\times}10^6\;m^3$ and $1,516{\times}10^6\;m^3$ and $744{\times}10^6\;m^3$ for 2,007 and 2008, respectively. Also, annual average amount of water resources was 1,861${\times}10^6\;m^3$ and $2,279{\times}10^6\;m^3$ and $1,227{\times}10^6\;m^3$ for 2,007 and 2008, respectively. Dongjin river basin water system for the analysis of agricultural water in water resources, runoff, agricultural water demand and usage surveys were analyzed, resulting in the total amount of water due to precipitation of the watershed of the $12.3{\times}10^9\;m^3$ ~$22.8{\times}10^9\;m^3$ and Dongjin River basin in waters flowing discharge is $7.4{\times}10^9\;m^3$~$16.1{\times}10^9\;m^3$, agricultural water demand and usage of each of $6.8{\times}10^9\;m^3$~$6.9{\times}10^9\;m^3$ and $4.9{\times}10^9\;m^3$~$7.1{\times}10^9\;m^3$ compared to the agricultural water demand was more likely. Agricultural water supply system in Dongjin river basin is complex because of devided branches to the main canal and branch canal. In this process, accurately assessment of water usage is very difficult. Therefore, systematic management of water resources and supply of agricultural water supply system to use the terms of the complexity and diversity by considering the appropriate level of agricultural water management systems will be needed. As a result of this study, it can be used water resources assessment in quantity, rational usefulness and basic planning of water resources development for water distribution.

Design and implementation of IoT based controllers and communication module interfaces for stand-alone solar system

  • Lee, Yon-Sik;Mun, Young-Chae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.1
    • /
    • pp.129-135
    • /
    • 2019
  • This paper is part of research and development for stand-alone solar system without commercial power supply. It implements firmware of controller for operation of stand-alone solar system by applying IoT technology and also develops communication modules that allow multiple solar lamps to send and receive data through wireless network. The controller of the developed stand-alone solar system can effectively charge the power generated by the solar module, taking into account the battery's charge and discharge characteristics. It also has the advantage of attaching wireless communication modules to solar lamp posts to establish wireless communication networks without incurring communication costs. In addition, by establishing IoT gateway middleware platform for each installation site, it forms a foundation to operate multiple solar lamp posts into multiple clusters. And, it is expected that the data collected in each cluster will be used to enable configuration and control of operational information, thereby inducing convenience and efficiency of remote operation and management.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

The RLG's Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 센서 RLG 전원 공급기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1488-1490
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch, The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply(HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

  • PDF