• Title/Summary/Keyword: discharge rate

Search Result 2,257, Processing Time 0.04 seconds

Clinical Characteristics of Asthmatic Patients Who Visited Emergency Room (응급실로 내원한 천식환자들의 임상적 특성)

  • Suh, Jung-Kyung;Lee, So-Ra;Lee, Sang-Youb;Lee, Sang-Hwa;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.290-297
    • /
    • 1997
  • Background : Despite remarkable progress of understanding the pathophysiology and therapy of bronchial asthma, asthma morbidity and mortality are on the rise. Also hospitalization and attending rates of emergency department for asthma have been increasing gradually. We analyzed clinical characteristics and prognosis of patients who visited emergency room due to asthma attack in order to define clinical characteristics of these group of patients. Method : We reviewed 105 adult asthmatic patients who attended emergency department of Korea University Hospital between August 1995 and July 1996, retrospectively. Results : 103 patients(56 female, 47 males, mean age : 48.6 years) attended-68 self referral, 18 practitioner referral and 17 OPD transfer- and 86 patients(83.5%) were admitted. Attending emergncy department was clearly more frequent in December(13.6%) and May(12.6%). Time lag between onset of asthmatic attack and arrival at the hospital was $14.2{\pm}15.5$ hour and initial peak expiratory flow rate was $166.7{\pm}68.3L/min$.(43.3% predicted) The commonest cause for visiting emergency room was aggravation of asthma due to upper respiratory tract infection in mild asthmatics. About half of them had history of previous ER visits. Their prognosis was not bad, but after discharge, about half of patients escaped from OPD follow-up. Conclusion : As a group they merit detailed attention and follow up arrangement. Clinician need to monitor and review the treatment plans, the medications, the patient's management technique, and the level of asthma control. For this group, plans for longer term treatment, including asthma education program and adjustment of overall treatment plan should be made.

  • PDF

Clinical Analysis of Spontaneous Pneumothorax (자연기흉의 임상적 고찰)

  • Son, Ji-Woong;Park, Jae-Yong;Kim, Kwan-Young;Chae, Sang-Chul;Kang, Tae-Kyong;Park, Ki-Su;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.374-382
    • /
    • 1999
  • Background: The aim of this study was to investigate etiologic factor, treatment, prognosis of spontaneous pneumothorax (SP). Material and Methods: The medical records of 225 cases of SP experienced at Kyungpook University Hospital from Jan. 1996 to Dec. 1997 were retrospectively analyzed. Results: The patients were 128 primary SP and 97 secondary SP. The mean age was $30{\pm}15.5$ years in primary SP and $51{\pm}7.4$ years in secondary SP. The ratio of male to female was 8:1 in primary SP and 5.5:1 in secondary SP. Smoker was more common in seconday SP (71.1 %) than primary SP (34.4%). About 70% of patients with primary and secondary SP was underweighted. The previous history of SP was present in 28.9% and 25.8% of primary and secondary SP, respectively. The main underlying lung diseases in secondary SP were inactive tuberculosis (68%), active tuberculosis (12.4%) and COPD (11.3%). Tube thoracostomy was performed in 96.8% and 97.9% of primary and secondary SP, respectively. The duration of chest tube insertion was longer in seconday SP ($18.2{\pm}19.59$ days) than primary SP ($7.5{\pm}6.57$ days). The open thoracotomy were performed in 22.7% and 10.3% of primary and secondary SP, respectively. The most com- mon indication of open thoracotomy was recurrence in primary SP and persistent air leak in secondary SP. During following-up of $17{\pm}7.8$ months, the recurrence rate in patients with conservative treatment was 16.5% and 11.8% of primary and secondary SP, respectively. The recurrence was most common within 1 month after discharge. Conclusion: Greater attention and research about SP are necessary for more efficient patient care.

  • PDF

Clustering according to Inpatients' Opinion on Hospital Foodservice and Analyzing Inpatient Response to Foodservice Qualify and Revisit Intention by the Cluster: In Case of S Hospital (입원환자의 급식서비스 인식에 따른 고객 군집화 및 군집별 급식서비스 질 평가, 재이용 의도 분석: S병원을 대상으로)

  • Lee, Hae-Young;Chang, Seung-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.10
    • /
    • pp.1491-1497
    • /
    • 2006
  • The purpose of this study was to analyze the relationship among inpatients' perceptions of foodservice quality, satisfaction and revisit intention. Questionnaires were hand-delivered to 350 inpatients and a total of 230 questionnaires were usable (response rate 65.7%), Statistical data analysis was completed using the SPSS Win 11.0 for descriptive analysis, independent t-test, $x^2$ test and k-means cluster analysis. The results of this study can be summarized as follows: The average score of overall importance of meal service in medical service was 4.25 out of 5.0, yet the score of overall quality of meal service and value had lower than importance score. A helpfulness to medical treatment (3.48), bringing customer happiness (3.18), overall satisfaction for foodservice (3.66), satisfaction based on expectation before discharge (3.53) and offering foodservice apt to hospital reputation (3.40) were measured as expressions of satisfaction. As a result of clustering analysis, two clusters were classified and named as affirmative opinion group and negative one. Expectation for four factors of foodservice quality between two groups had no significance. But affirmative opinion group had significantly higher score than negative one in perception and satisfaction. Affirmative customers' intention to revisit in the near future was evaluated as high in both considering general medical service (4.04) and reflecting meal service level (3.84).

Thyroglossal Duct Cyst and Fistula (갑상설관 낭포 및 루)

  • 최종욱;김한상;안문성;김춘길;주양자
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.10-10
    • /
    • 1981
  • The thyroglossal duct cyst is relatively rare disease that derived congenitally from the remnant of thyroglossal duct and that was found anywhere from the foramen cecum to pyramidal lobe of thyroid. We studied the 62 cases of above disease who admitted and operated at E.N.T. dept. of N.M.C. for 20 years since 1961 to 1980 on the clinical and histopathological aspect, and we concluded following results. 1. In the age distribution, 45 cases(72.6%) were under 20 years, and in the age distribution of the known on-set of symptoms, 26 cases(58.0%) were under 10 years. In the duration, 23 cases(37.0%) were under 1 year. The sex ratio of male to female revealed 1.2:1. 2. The palpable mass were complained at 48 cases(77.4%) and 14 cases(22.6%) complained of the discharge from sinus tracts and the other complaints were dysphagia and odynophagia, etc. 3. In location 55 cases (88.7%) were at midline, 1 case(1.6%) was at right and 6 cases(9.7%) were left sided. And 47 cases(75.8%) were situated at infrahyoid region, 11 cases(17.7%) at suprahyoid, 3 cases(4.8%) at suprasternal, only 1 case(1.6%) at intralingual region. 4. In 27 cases formed fistulae, spontaneous occurrance were 7 cases and artificial occurrance were 20 cases. 5. In histopathologically among 41 cases preserving available slides, 5 cases(12.2%) had single duct and 20 cases(48.8%) had multiple accessory ducts, but 16 cases were impossible to detect the ducts. The lining epithelium composed of chiefly respiratory and squamous epithelium. 15 cases had inflammatory reaction at periductal area and 7 cases had around the cysts. The ectopic thyroid tissue was found on 6 cases(14.6%) and 1 case had the follicular adenoma. 6. In the recurrance rate among 43 cases performed sistrunk type operation, 2 cases (4.6%) recurred, and among 19 cases performed simple removal of cysts, 4 cases (21.1%) recurred.

  • PDF

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Improvement of Energy Density in Supercapacitor by Ion Doping Control for Energy Storage System (에너지 저장장치용 슈퍼커패시터 이온 도핑 제어를 통한 에너지 밀도 향상 연구)

  • Park, Byung-jun;Yoo, SeonMi;Yang, SeongEun;Han, SangChul;No, TaeMoo;Lee, Young Hee;Han, YoungHee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.209-213
    • /
    • 2019
  • Recently, demand for high energy density and long cycling stability of energy storage system has increased for application using with frequency regulation (F/R) in power grid. Supercapacitor have long lifetime and high charge and discharge rate, it is very adaptable to apply a frequency regulation in power grid. Supercapacitor can complement batteries to reduce the size and installation of batteries. Because their utilization in a system can potentially eliminate the need for short-term frequent replacement as required by batteries, hence, saving the resources invested in the upkeep of the whole system or extension of lifecycle of batteries in the long run of power grid. However, low energy density in supercapacitor is critical weakness to utilization for huge energy storage system of power grid. So, it is still far from being able to replace batteries and struggle in meeting the demand for a high energy density. But, today, LIC (Lithium Ion Capacitor) considered as an attractive structure to improve energy density much more than EDLC (Electric double layer capacitor) because LIC has high voltage range up to 3.8 V. But, many aspects of the electrochemical performance of LIC still need to be examined closely in order to apply for commercial use. In this study, in order to improve the capacitance of LIC related with energy density, we designed new method of pre-doping in anode electrode. The electrode in cathode were fabricated in dry room which has a relative humidity under 0.1% and constant electrode thickness over $100{\mu}m$ was manufactured for stable mechanical strength and anode doping. To minimize of contact resistance, fabricated electrode was conducted hot compression process from room temperature to $65^{\circ}C$. We designed various pre-doping method for LIC structure and analyzing the doping mechanism issues. Finally, we suggest new pre-doping method to improve the capacitance and electrochemical stability for LIC.

Dry reforming of Propane to Syngas over Ni-CeO2/γ-Al2O3 Catalysts in a Packed-bed Plasma Reactor (충전층 플라즈마 반응기에서 Ni-CeO2/γ-Al2O3 촉매를 이용한 프로페인-합성 가스 건식 개질)

  • Sultana, Lamia;Rahman, Md. Shahinur;Sudhakaran, M.S.P.;Hossain, Md. Mokter;Mok, Young Sun
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.81-90
    • /
    • 2019
  • A dielectric barrier discharge (DBD) plasma reactor packed with $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst was used for the dry ($CO_2$) reforming of propane (DRP) to improve the production of syngas (a mixture of $H_2$ and CO) and the catalyst stability. The plasma-catalytic DRP was carried out with either thermally or plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst at a $C_3H_8/CO_2$ ratio of 1/3 and a total feed gas flow rate of $300mL\;min^{-1}$. The catalytic activities associated with the DRP were evaluated in the range of $500{\sim}600^{\circ}C$. Following the calcination in ambient air, the ${\gamma}-Al_2O_3$ impregnated with the precursor solution ($Ni(NO_3)_2$ and $Ce(NO_3)_2$) was subjected to reduction in an $H_2/Ar$ atmosphere to prepare $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst. The characteristics of the catalysts were examined using X-ray diffraction (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectrometry (EDS), temperature programmed reduction ($H_2-TPR$), temperature programmed desorption ($H_2-TPD$, $CO_2-TPD$), temperature programmed oxidation (TPO), and Raman spectroscopy. The investigation revealed that the plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst exhibited superior catalytic activity for the production of syngas, compared to the thermally reduced catalyst. Besides, the plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst was found to show long-term catalytic stability with respect to coke resistance that is main concern regarding the DRP process.

Spatiotemporal and Longitudinal Variability of Hydro-meteorology, Basic Water Quality and Dominant Algal Assemblages in the Eight Weir Pools of Regulated River(Nakdong) (낙동강 8개 보에서 기상수문·기초수질 및 우점조류의 시공간 종적 변동성)

  • Shin, Jae-Ki;Park, Yongeun
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.4
    • /
    • pp.268-286
    • /
    • 2018
  • The eutrophication and algal blooms by harmful cyanobacteria (CyanoHAs) and freshwater redtide (FRT) that severely experiencing in typical regulated weir system of the Nakdong River are one of the most rapidly expanding water quality problems in Korea and worldwide. To compare with the factors of rainfall, hydrology, and dominant algae, this study explored spatiotemporal variability of the major water environmental factors by weekly intervals in eight weir pools of the Nakdong River from January 2013 to July 2017. There was a distinct difference in rainfall distribution between upstream and downstream regions. Outflow discharge using small-scale hydropower generation, overflow and fish-ways accounted for 37.4%, 60.1% and 2.5%, respectively. Excluding the flood season, the outflow was mainly due to the hydropower release through year-round. These have been associated with the drawdown of water level, water exchange rate, and the significant impact on change of dominant algae. The mean concentration (maximum value) of chlorophyll-a was $17.6mg\;m^{-3}$ ($98.2mg\;m^{-3}$) in the SAJ~GAJ and $29.6mg\;m^{-3}$ ($193.6mg\;m^{-3}$) in the DAS~HAA weir pools reaches, respectively. It has increased significantly in the downstream part where the influence of treated wastewater effluents (TWEs) is high. Indeed, very high values (>50 or $>100mg\;m^{-3}$) of chlorophyll-a concentration were observed at low flow rates and water levels. Algal assemblages that caused the blooms of CyanoHAs and FRT were the cyanobacteria Microcystis and the diatom Stephanodiscus populations, respectively. In conclusion, appropriate hydrological management practices in terms of each weir pool may need to be developed.

Analysis of long-term water level change of Dongrae hot spring using time series methods (시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Lee, Cheol-Woo;Lee, Jong-Tae;Lim, Woo-Ri
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.529-544
    • /
    • 2018
  • Dongrae hot spring belongs to the residual magma type and has a long history of bathing since the Silla dynasty in Korea. Due to long development of hot spring water, it is expected that the amount of hot spring water in Dongrae hot spring has been changed. In this study, long-trem water level data of Dongrae hot spring were examined for recognizing the change of the hot spring. By the fluctuation analysis of the hot spring water level from January 1992 to July 2018, the maximum and minimum annual drawdowns of no. 27 well were 137.70 and 71.60 meters, respectively, with an average drawdown of 103.39 m. On the other hand, the maximum and minimum annual drawdowns of no. 29 well were 137.80 and 71.70 meters, with an average drawdown of 103.49 m. Besides, drawdown rate became bigger in recent years. As a result of analyzing autocorrelation of the two wells, the correlation coefficient ranged from 0.919 to 0.991, showing seasonal groundwater level fluctuation. The cross correlation analysis between water level and precipitation as well as water level and hot spring discharge resulted in the correlation coefficients of -0.280 ~ 0.256 and 0.428 ~ 0.553, respectively. Therefore, using Dongnae hot-spring water level data from 1992 to 2018, the Mann-Kendall test and Sen's test showed that the continuous decline of water level was mainly caused by the pumping of the hot spring water among various reasons.