• Title/Summary/Keyword: discharge electrode shape

Search Result 103, Processing Time 0.023 seconds

A Study on the Electrical Discharge Blind Hole Tap Machining of STD11 with Copper Electrode (구리전극봉을 이용한 합금공구강재(STD11)의 비관통 방전 탭 가공에 관한 연구)

  • Park, In-Soo;Wang, Duck-Hyun;Kim, Gi-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.38-44
    • /
    • 2017
  • The technology of electrical discharge tap machining may be appropriate for making thread out of highly brittle material. Especially, it is very difficult to machine tap with the traditional method if the brittle material has been hardened by quenching. In this study, the shape of electrical discharge blind hole tap machining was analyzed by discharge time, discharge current, and the flushing hole condition after quenched the tool steel of STD11 has discharged the tap shape with a screw-shaped copper(Cu) electrode. An experimental design was planned and analyzed by Taguchi robust experimental design. The result showed that the shape of the blind hole discharge tap was influenced by the flushing hole, discharge time, and discharge current. The most important factor of the processing conditions was found to be the discharge current. When blind hole EDM with a copper electrode with a flushing hole was conducted, the discharged shape was found to be smooth and the angle of the discharged tapped thread was also found to be close to the thread angle of $60^{\circ}$. As the values of discharge time and discharge current increased, the EDMed surface coarsened due to the increase of the single discharge energy and the shape of the thread collapsing.

A Study on the Relationship between Cell Structure and Discharge Characteristics of Surface Discharge AC PDP (표면 방전형 AC PDP의 셀 구조와 방전특성의 상관관계에 관한 연구)

  • Shin, Joong-Hong;Lee, Woo-Geun;Kim, Jun-Ho;Kim, Gyu-Seob;Yoo, Jung-Hee;Park, Chung-Hoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.133-140
    • /
    • 1999
  • The relationships between discharge characteristics and sustain electrode shape are studied in AC PDP by calculating the electric field and measuring discharge voltage, luminance and current. The maximum electric field is obtained for the triangle shape electrode. It is 1.8 times larger than uniform electric field type. It has been shown thatthe firing voltage is largely affected by the degree of electric field concentration. But, as the difference of the maximum and minimum value of electric field in a cell increases, the luminance and luminance efficiency decrease. And, the charge variation during discharge is proportional to the area of electrode.

  • PDF

Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation (장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

The Research on the Nanoparticles Prepared by Arc-Discharge Method as Anode Materials for Lithium Ion Batteries (아크방전으로 제조된 나노입자를 이용한 리튬이온전지 음극재료의 연구)

  • Kim, Hyeong-Jo;Tulugan, Kelimu;Kim, Hyung-Jin;Park, Won-Jo
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.104-109
    • /
    • 2013
  • Tin and Tinoxide nanoparticles were prepared by arc-discharge nanopowder process. The negative electrode were fabricated using Tin and Tinoxide nanopower. The microstructure and electrochemistry properties were investigated and compared between Tin and Tinoxide. The oxidation film has microstructure of core/shell type and the shell which was attached around Tin nanoparticle consisted of amorphous $SnO_2$. The shape of Tinoxide nanoparticles was formed with irregular shape in comparison with Tin particle. Initial discharge capcity of Tinoxide electrode possesed about 1000mAh/g, which is about 320mAh/g higher than Tin electrode. Irreversible capacity of Tin electrode is much higher than Tinoxide. The cycle performance of Tinoxide electrode was indicated that is batter than Tin. The Tin negative electrode lost most of capacity after 4 cycle but Tinoxide electrode still retained the capacity. The Tinoxide does show some promise as Li-ion battery anode due to their large reversible capacity at low potentials.

The Characteristics of Showering Discharge Type Ozonizer (Showering Discharge형 오존발생장치의 특성)

  • Kim, Keum-Yeung;Mun, Kyung-Su;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Jeon, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2248-2250
    • /
    • 1999
  • In this paper, showering discharge type ozonizer has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Study on Surface Plasmon Electrode Using Metal Nano-Structure for Maximizing Sterilization of Dielectric Discharge (유전체 방전 살균 극대화를 위한 금속 나노 구조를 이용한 표면 플라즈몬 전극에 관한 연구)

  • Ki, Hyun-Chul;Oh, Byeong-Yun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.80-84
    • /
    • 2018
  • In this study, we investigated plasmon effects to maximize the sterilization of dielectric discharge. We predicted the effect using the finite difference time domain (FDTD) method as a function of electrode shape, size, and period. The structure of the electrode was designed with a thickness of 100 nm of silver nanoparticles on a glass substrate, and was varied according to the shape, size, and period of the electrode hole. Based on the results, it was confirmed that the effect of plasmons was independent of the shape of the electrode hole. It was thus confirmed that the plasmon effect depended only on the size and period of the holes. Further, the plasmon effect was affected by the size rather than period of the holes. Because the absorption of light by the metal varied according to the size of the hole, the plasmon effect generated by the absorption of light also varied. The best results were obtained when the radius and period of the electrode holes were $0.1{\mu}m$ and $0.4{\mu}m$, respectively.

An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode (관형 코로나 방전전극을 이용한 이온풍속의 최대화)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries (핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구)

  • Cheong Seongir;Lee Jaekeun;Chung Dongkyu;Ahn Youngchull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration (방전공격과 방전극 형상이 오존발생농도에 미치는 영향)

  • Park, Seung-Lok;Lee, Jae-Chan;Jung, Sung-Jin;Moon, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF