• 제목/요약/키워드: discharge cleaning

검색결과 92건 처리시간 0.027초

표면 자정성을 갖는 방음판 개발에 관한 연구 (A study on the development of soundproof panel with self-cleaning properties)

  • 윤제원;임정빈;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.229-233
    • /
    • 2003
  • The soundproof barrier used to reduce the traffic and rail noise is usually designed to the point of view of the acoustic performance such as absorption ratio and transmission loss. But, because the surface of soundproof barrier is polluted by the air pollutant or discharge gas of automobiles, so it's surface cleary maintained by the periodic washing with detergent. But in this case the environmental pollution and the working expenses are worried. So, the objective of this study is to develope the soundproof panel with the self-cleaning properties only by raining.

  • PDF

초임계 이산화탄소를 이용한 초순수 건식 세정기술 (Ultra Dry-Cleaning Technology Using Supercritical Carbon Dioxide)

  • 정승남;김선영;유기풍
    • 청정기술
    • /
    • 제7권1호
    • /
    • pp.13-25
    • /
    • 2001
  • 정밀 기계산업과 반도체 산업의 진보와 더불어 대상물의 초순도 세정이 하이테크 산업발전에 가장 중요한 핵심기술로 부각되고 있다. 현재 초순수 세정은 크게 습식세정과 건식세정으로 분류하고 있다. 습식세정의 경우 오랜 경험과 높은 세정효율을 보이고 있지만, 다량의 탈이온수에 과산화수소, 황산, 불산 또는 수산화 암모늄 등의 독성첨가제를 반복적으로 사용하고 있어 독성 폐수발생등 심각한 환경오염을 유발하고 있다. 따라서, 최근에는 습식 세정에 따른 환경오염의 문제를 개선하기 위한 노력으로 몇 가지 건식 세정기술이 개발되고 있다. 최근 들어 건식세정 방법 중에 소위 초임계상태의 환경 용매를 사용하는 기술이 개발되고 있으며, 높은 세정효율과 더불어 환경친화성이 높은 유망한 기술로 받아들여지고 있어 국제적인 관심이 집중되고 있다. 이 논문에서는 초임계 이산화탄소 세정에 관심을 두어, 초임계 용매의 물리화학적 특성과 환경친화측면, 세정공정의 엔지니어링, 그리고 국내외 기술 현황을 종합적으로 분석 평가하였다.

  • PDF

플라즈마 블라스팅을 이용한 유류오염토양의 투수성과 정화효율 개선을 위한 실험적 연구 (An Experimental Study to Improve Permeability and Cleaning Efficiency of Oil Contaminated Soil by Plasma Blasting)

  • 장현식;김기준;송재용;안상곤;장보안
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.557-575
    • /
    • 2020
  • 유류오염 토양의 투수성 및 정화효율을 개선하기 위하여 고전압 아크 방전에 의한 플라즈마 블라스팅을 토양에 적용하였다. 이 연구를 위하여 고전압 발생장치를 새로 제작하였고, 실트질 모래인 토양시료, 토양시료에 소석회를 혼합한 시료와 토양시료에 시멘트를 혼합한 세 종류의 토양시료를 다져서 소형 토조와 대형 토조를 제작한 후 각각의 토조내에서 플라즈마 블라스팅을 시행하여 유체확산의 범위와 투수성의 변화를 측정하였다. 플라즈마 블라스팅이 시행된 토양시료에서는 플라즈마 블라스팅이 시행되지 않은 대조군에 비해 유체의 확산 부피가 약 11~71% 증가하였다. 낮은 전압하에서 플라즈마 블라스팅이 시행되면 토양 내에서는 구조적 취약면(다짐면)을 따라 수평적 확산이 우세하게 나타났으나 높은 전압에 의한 플라즈마 블라스팅은 토양 내에 구형의 입체적인 확산을 발생시켰다. 플라즈마 블라스팅은 투수성 또한 증가시켰으며, 소석회 및 시멘트가 혼합된 토양에서 더욱 뚜렷하게 관찰되어, 플라즈마 블라스팅이 시행된 시료들은 대조군 시료에 비해 투수계수가 450~1,052% 범위로 증가하였다. 플라즈마 블라스팅이 1회만 실시된 토양시료의 투수계수는 방전 전압이 높아질수록 증가하였으나 동일한 전압으로 여러 번의 블라스팅이 시행된 토양시료의 투수계수는 증가하거나 감소하였다. 토양시료에 경유를 이용하여 인위적으로 오염시킨 토양시료에 플라즈마 블라스팅을 실시하여 정화효율을 측정하였다. 플라즈마 블라스팅이 시행되면, 방전지점 근처의 토양에서는 평균 393%, 방전지점으로부터 20 cm 이상 이격된 하부 토양에서는 평균 239% 정도의 정화효율이 개선되었으나 방전 전압과 정화효율은 상관성을 보이지 않았다. 위의 결과는 플라즈마 블라스팅이 토양의 투수성과 정화효율을 상당히 개선하므로, 유류오염 토양의 원위치 정화에 효율적으로 이용될 가능성을 보여주었다.

반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구 (A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water)

  • 손영수;함상용;문세호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I) (Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode)

  • 조국희;김영배;서길수;이형호;이상근;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

터널용 전기집진시스템 개발을 위한 방전극 설계 (Study on Discharge Electrode Design applied for Road Tunnel)

  • 김종률;원종웅;장춘만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1238-1243
    • /
    • 2009
  • As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.

  • PDF

AC PDP 의 방전 특성에 미치는 MgO 활성화 영향에 관한 연구 (The Effects of MgO Activation Process on the Discharge Characteristics of AC PDP)

  • 김영기;김준호;손제봉;박병언;박명주;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.209-214
    • /
    • 1999
  • This paper deals with the effects of activation process of MgO thin film on the dielectric characteristics of surface discharge type AC PDP. The discharge voltage decreased with increase in the MgO activation time and temperature until $400^{\circ}C$ under the condition of clean high vacuum. However, for the sample activated above $430^{\circ}C$ the discharge voltage increased. These results may be explained by the MgO morphology change and surface cleaning in the process of activation.

  • PDF

플라즈마 처리된 PET 필름의 표면분석에 관한 연구 (A Study on the Surface Analysis of Plasma-Treated PET Film)

  • 임경범;최훈영;이석현;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.596-600
    • /
    • 2004
  • In this study, the surface properties of PET film were analyzed after plasma surface treatment. After plasma treatment of surface roughness and XPS were evaluated to analyze the chemical property, while the surface potential decay and surface resistance rate was measured to analyze the electric관 characteristic. When plasma discharge treatment was conducted for less than 10 minutes, the electrical insulating property was improved by evaporation of low molecular weight materials and cleaning of surface. However, when the treatment was conducted for more than 10 minutes, the insulating property was decreased due to excessive discharge energy. Analyses of chemical characteristics showed that 10-minute treatment resulted in increase of C-O and O=C-O bonds. However, when treated for more than 10 minutes. they were relatively decreased.