• Title/Summary/Keyword: discharge cell

Search Result 827, Processing Time 0.028 seconds

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Toward Efficacy Improvement in a PDP Discharge Cell from Structural Considerations

  • Tachibana, Kunihide
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.20-23
    • /
    • 2009
  • The efficacy improvement issues in a unit discharge cell have been approached from the structural considerations. The tested cell designs include (a) a coplanar type with annular auxiliary electrode buried in barrier ribs, (b) a coplanar type with split auxiliary electrodes also burred in barrier ribs and (c) a coaxial type with a floating electrode stacked on the base electrode. From spatiotemporally resolved optical images of near-IR emission taken by a gated-ICCD camera and relative VUV emission intensity estimated by laser absorption spectroscopy, the differences in the discharge and light emission performances of those three cell types have been compared and discussed.

  • PDF

The Impedance Properties of Poly(p-phenylene)-based Carbon/Li cell (PPP-based Carbon/Li cell의 임피던스 특성)

  • 류현옥;홍성문;김주승;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.283-285
    • /
    • 1997
  • We have obtained disordered carbon by pyrolyzing PPP in a nitrogen atmosphere for 8 hour at 700$^{\circ}C$. AC impedance property was measured with the PPP-based carbon/EC-DEC/Li cell. The impedance spectra of the cell were measured during the 1st discharge proceed. As the result of measurement the cell resistance decreased in intial discharge, but increase in final discharge.

  • PDF

A CHARGER/DISCHARGER FOR MODELING OF SERIAL/PARALLEL CONNECTED NI-MH BATTERY

  • Heo, Min-Ho;Ahn, Jae-Young;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.554-559
    • /
    • 1998
  • Equalizing the state of charge of cell that affects the charge/discharge quality and efficiency of the battery through the charge/discharge characteristic experiments of battery source, we develope the high efficiency charge/discharge system which would be used in serial HEV with the constant engine-generator output. For this, establishes the electrical model of Ni-MH battery appropriate to the high efficiency charge/discharge conditions. There is no model of Ni-MH cell, so we used Ni-Cd model and obtain the Ni-MH model through the experiment. A reason that each cell has the same charge/discharge property for applying the cell model to serial/parallel connected battery source extensively is needed. Therefore, in this paper, propose the Ni-MH charger/discharger has the equalization charging function and selectable cut-off function.

  • PDF

Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel (벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구)

  • 신범제;정희섭;서정현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

High Efficacy Plasma Display Utilizing Macro Discharge Cell Structure with Long Electrodes Gap (Long Electrode Gap을 가진 Macro Cell에서의 고효율 PDP 특성 연구)

  • Kim, Min-Tae;Heo, Jun;Kim, Yun-Gi;Kim, Dong-Hyun;Lee, Hea-June;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1314-1318
    • /
    • 2012
  • Recently, applications of plasma display to the large public display and transparent display gain much attention. With this background, we report characteristics of opposite electrodes discharge cell with long electrode gap in comparison with conventional co-planar surface discharge. The cell size of test panel is $2950{\mu}m{\times}840{\mu}m$, which corresponds to that of the display having diagonal size of 130" with XGA resolution. Electrode gap of co-planar and opposite electrode structure are $240{\mu}m$ and $500{\mu}m$ respectively. These gap dimensions provide similar driving voltage windows. Experimental results show that opposite discharge provides approximately four fold higher luminous efficacy compared with that of the surface discharge. Resulting efficacy is found to be higher than 19 lm/W in green phosphor with 10 KHz continuous pulse operation.

AC PDP(Plasma Display Panel)의 방전 특성 해석

  • 황기웅;정희섭;서정현
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1997.07a
    • /
    • pp.173-176
    • /
    • 1997
  • A numerical analysis of the micro-discharge in an AC pplasma dispplay cell has been made using time-deppendent, 2-dimensional multi-fluid equations to understand the discharge pphysics of He-Xe discharge. The time deppendent distribution of the electron tempperature, densities of electrons, various ions and excited sppecies, and the effects fo the wall charge accumulated on the dielectric surface are obtained and comppared with the results of direct observation of time deppendent behavior of VUV and visible sppectra from single discharge cell observed using a gated, image intensified CCD to elucidate the discharge physics.

  • PDF

Charge/discharge Properties of Flyash as a Anode for Lithium Polymer Battery (리튬 폴리머 전지용 Flyash 부극의 충방전 특성)

  • Song, Hee-Woong;Kim, Jong-Uk;Park, Gye-Choon;Gu, Hal-Bon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.968-970
    • /
    • 1999
  • The trend of increasing of portable electric devices and demand for global environmental conservation have demands the development of high energy density rechargeable batteries. Lithium polymer battery has excellent theoretical energy density and energy conversion efficiency. Lithium polymer battery, included solid polymer electrolyte(SPE), can be viewed as a system suitable for wide applications from thin film batteries for microelectronics to electric vehicle batteries. The purpose of this paper is to research and development of flyash anode for lithium polymer battery. We investigated AC impedance response and charge/discharge characteristics of flyash/SPE/Li cells. The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell increased very slowly during discharge process from 3.11V to 0.478V. And then the cell resistance was decreased at discharge process from 10% SOC to 0% SOC. Also, The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell decreasing very slowly during charge process. And then the cell resistance was increased after 20th discharge precess. The discharge capacity based on flyash of 1st and 20th cycles was 276mAh/g and 143mAh/g.

  • PDF

Design of Hybrid System for Battery Charge·Discharge using Photovoltaic/Fuel cell (태양광/연료전지용 배터리 충·방전 하이브리드 시스템 설계)

  • Park, Bong-Hee;Jo, Yeong-Min;Choi, Ju-Yeop;Cho, Sang-Yoon;Choy, Ick;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.123-129
    • /
    • 2014
  • Photovoltaic and fuel cell systems can be used as power source in mobile robots. At this time the photovoltaic system generally generate power in daytime. The starting time of fuel cell is slower than the lithium battery. To compensate for these disadvantages, a battery charge-discharge system is used. Especially the bi-directional converter is used mainly in the charge-discharge method. The controller in a buck converter controls the input voltage of the converter to meet the maximum power point tracking(MPPT) performance. First of all, the simulations of hybrid system for battery charge-discharge system in each step simulated using solar and fuel cell modeling as input source in PSIM. Experiment of the buck and bi-directional converter system is conducted through using photovoltaic/fuel cel simulator(pCube) instead of solar and fuel cell. This hybrid system for battery charge discharge using photovoltaic/fuel cell generates emergency power for the communication system in mobile robot.