• Title/Summary/Keyword: discharge area

Search Result 1,549, Processing Time 0.028 seconds

A Study on the Impact of Runoff Discharge by Developing in Upper Area (유역 상류지역의 개발이 유출에 미치는 영향에 관한 연구)

  • Kang, Sang-Hyeok;Kim, Kyoung-Nam
    • Spatial Information Research
    • /
    • v.15 no.2
    • /
    • pp.147-158
    • /
    • 2007
  • Kangwon province has been suffering from the various types of disasters and these disasters stand In the way to sustainable development. The heavy rainfall by typhoon RUSA in 2002 damaged to property and bodily injury, and gave us a lesson. Even if the refuge activities plan by local government plan for disaster were established with rainfall event, it could not its role in practice. Beside it, the potential disaster risk remains still in existence because the disaster restoration work aims to original state. Therefore, in this study we focused on the point at issue of developing in upper area and its impact on discharge hydrograph.

  • PDF

Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin (낙동강수계 수질오염총량관리를 위한 유량조사 평가)

  • Kim, Gyeong-Hoon;Kim, Yong-Seok;Park, Bae-Kyung;Yoon, Jong-Su;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

Large-area Uniform Deposition of Amorphous Hydrogenated Carbon Films using a Plasma CVD Method (플라즈마 CVD 법을 이용한 대면적 균일한 비정질 탄소 막 증착)

  • Yun, Sang-Min;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.411-414
    • /
    • 2009
  • It has been investigated for the film uniformity and deposition rate of a-C:H films on glass substrate and polymeric materials in the presence of the modulated crossed magnetic field. We used Plasma CVD, i.e, using a crossed electromagnetic field, for uniform depositing thin film. The optimum discharge condition has been discussed for the gas pressure, the magnetic flux density and the distance between substrate and electrodes, As a result, it is found that the optimum discharge conditions are $CH_4$ concentration $CH_4$=10 %, modulated magnetic flux density B=48 Gauss, pressure P=100 mTorr, discharge power supply voltage V=l kV under these experimental conditions. By using these experimental condition, it is possible to prepare the most uniform film extends over about 160 mm of the film width. In this study, we deposited a-C:H thin film on glass substrate, and have a plan that using this condition, study depositing a-C:H thin film on polymeric substrate in next studies.

A Study on Flash Flood Warning Trigger Rainfall in Mountainous Area (산악지역 돌발홍수 기준우량 결정에 관한 연구)

  • Jun, Kye-Won;Oh, Chae-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.1
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to estimate the critical flood discharge and flash flood trigger rainfall for alarm system providing for a flash flood in mountainous area. The flash flood need non-linear approaching method, because rainfall-runoff is nonlinear and it is difficult to explain the existing linear rainfall-runoff. Hydrological characteristics would be utilized to apply such as hydrologic modelling or basin management. This study was effectively estimated a topographic characteristic factor of basin using the GIS. Especially, decided stream order using GIS at stream order decision that is important for input variable of GCIUH. A flash floods defined as a flood which follows shortly after a heavy or excessive rainfall event, with a few hours. In this study, we gave a definition that a critical flood for alarm is the flood when valley depth judging dangerous depth is over 0.5m depth from the bottom of channel. Result that calculate threshold discharge to use GCIUH, at the Mureung valley basin, flash flood trigger rainfall was 16.34mm in the first 20minutes when the threshold discharge was $14.54m^3/sec$.

A Study of Hydraulic Turbine Design for The Discharge Water Energy Harvesting (방출 수 에너지 하베스팅을 위한 수차 설계에 관한 연구)

  • Cheong, Han Seok;Kim, Chung Hyeok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.78-83
    • /
    • 2021
  • We modeled the helical turbine and three modified helical turbines for the structure of the hydraulic turbine for discharge water energy harvesting. A structure that can reduce the load applied to the blade by placing a center plate is our basic concept. The shape was reduced to 1/5, fixed to a size of 240 mm in height and 247 mm in diameter, and modeled by changing the width and the angle of the hydraulic turbine blade. The pipe inner diameter of the simulation pipeline equipment is 309.5 mm, and the simulation section was 4 m in the entire section. The flow velocity was measured for two cases, 1.82 m/s and 2.51 m/s, with the parameters being the amount of power generation, hydraulic turbine's torque, and hydraulic turbine's rotation speed. The measurement results confirmed that the flow velocity at the center, which has no pipe surface resistance, has a great influence on the amount of power generation; therefore, the friction area of the turbine blade should be increased in the center area. In addition, if the center plate is placed on the helical turbine, durability can be improved as it reduces the stress on the blade.

Analysis of Air Circulation in Oyster Mushroom Farm

  • Jeong, Won-Geun;Lim, Hack-Kyu;Kim, Tae-Han
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • Oyster mushroom farm which could not meet optimum temperature range yields non-uniform sized, low quality products. Thus, this study, utilizing STAR CCM+, one of the computational fluid dynamics (CFD) programs, analyzed the impact of air circulation and temperature distribution. Methods: After we visited numerous mushroom farms, we measured the temperature at the discharge ports of heaters, fan capacity, and the locations of the air circulators in the farms. According to the data, most mushroom growers installed the heaters near the entrance and discharge ports of the heaters at the third growing bed on the same height as the heaters in the entrance. The temperature at the discharge port of heater was $1,26^{\circ}C$, and the fan capacity was 4,500 $m^3$/hr. The air circulator was placed in the center of the mushroom farm 50cm above the ground, and its capacity of inlet port was 1,100 $m^3$/hr and discharge port 1,600 $m^3$/hr. The mushroom farm was insulated. Results: According to the analysis of the temperature distribution in the vertical plane of the entrance side, no air circulation causes the high temperature zone of 296~299K at the discharge port of the heater to take up 34% of area while the operation of air circulators causes it to occupy only 9%. This means that not using air circulators leads to a concentration of high temperature at the discharge port near the entrance. In addition, with the results of the analysis of the temperature distribution in the vertical planes of the center, no air circulation causes the temperature zone of 295~298K at the discharge port of the heater to take up 48% of area while the operation of air circulators causes it to occupy 80%. This shows that the high outlet port temperature disseminated to the center. Conclusions: After ninety minute operation of both heater and air circulator, the interior temperature became stabilized in the mushroom farm. Air circulation made the high temperature at the discharge port disseminate to the center and exit in the farm and equalize the temperature distribution.

A Study on Estimation of Submarine Groundwater Discharge Distribution area using IR camera and Field survey around Jeju island (열화상카메라와 현장조사를 이용한 제주 주변 해역의 해저 용천수 분포 지역 추정 연구)

  • Park, Jae-Moon;Kim, Dae-Hyun;Yang, Sung-Kee;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.861-866
    • /
    • 2015
  • This study was aimed to detect area of Submaine Groundwater Discharged(: SGD) around Jeju island using by remote sensing. Sea Surface Temperature(SST) was identified using IR camera on Unmaned Aerial Vehicle(UAV) at Gimnyeong port in study area. Then SGD location was detected by comparing range of SGD temperature. Generally, range of SGD temperature is distributed 15 to 17 like underground water. The result, SGD location was detected by SST distribution of Gimnyeong port recorded by IR camera in the southwest of study area.

Clinical Experience of Head-Injured Patients in the Rural Area (농촌지역에서의 두부외상 환자의 임상경험)

  • Kim, Il-Man
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1050-1054
    • /
    • 2000
  • Objective : The incidence of head injury has been increasing in the rural area. The author investigated the clinical features and difficulties in care of the acute head-injured patients in this area. Method and Material : The authors performed a retrospective review of radiological data and clinical records in patients with mild to moderate head injury. Cause, type of craniocerebral injury, delayed intracranial lesions, complications, its relation to alcohol abuse, and outcome were analyzed. Results : In total of 68 cases, 20(29.4%) victims were associated with acute alcohol intoxication. Motor vehicle accident was the leading cause of head injury and the most common craniocerebral lesion was basilar skull fracture. Eight(11.8%) patients showed delayed radiological and clinical deterioration and 40(58.8%) were followed-up regularly after discharge. The subdural hygroma was commonly noted in the elderly and alcoholics. Causes of thirty events that resulted in an atypical and difficult neurosurgical practice were as follows : delayed admission, premature discharge against doctor's request, refusal of radiological studies and admission, misunderstanding of disease entity, and unreasonable desire of transfer to tertiary hospitals. Inaccurate initial diagnoses were made by emergency doctors in twenty patients. During the course of treatment, there were a few complications such as alcohol withdrawal, acute otitis media, cerebrospinal fistula, facial weakness, and posttraumatic seizure. Outcome was good in 60(88.2%) patients. Conclusion : Most of minor head trauma patients in this series have shown good results, but we have to consider some possible complications and delayed intracranial lesions in these patients that should be managed with special cautions with various kinds of treatment difficulties.

  • PDF

Mutagenicity of River Water of Nakdong River Estuary in Korea (낙동강 하구수의 변이원성에 대한 연구)

  • ;;Ryuich Otsu
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The mutagenicity of the river water of Nakdong river estuary was determined by Ames test using the blue rayon suspension method. Samples were collected from 10 sites in the estuary once in each season of 1998. The samples collected from the sites where industrial waste discharge on May were mutagenic, but the other samples were not mutagenic. The sample collected from the site 1 located near the industrial area (Hadan-dong) were highly mutagenic in the TA98 with (+S9) and without (-S9) mix as well as in the TA100 with (+S9) and without (-S9) S9 mix, suggesting that the river water of this site is polluted by direct and indirect mutagens of frame-shift type as well as direct and indirect mutagens of base-replacement type. The positive mutagenicity, although relatively low, was also detected in TA98 with (+S9) and without (-S9) S9 mix in the extract of the site 4 near the industrial area(Jangrim-dong), suggesting that the primary mutation type is frame-shift. The negative mutagenicity from July to December at the sites (1-4) near the industrial area seems to be affected by the low economic growth rate in 1998 in Korea. On the other hand, the negative mutagenicity in all extracts collected from the sites 5-10 near the residential area where living sewage discharge, suggests that the river water was not polluted by mutagens.

  • PDF

Performance Variation of the Refrigerated Display Case with Air Curtain in Accordance with Back Pressure Condition (배압에 따른 에어커튼형 냉동용 전시케이스의 성능변화)

  • Sung, Sun-Kyung;Ahn, Kyo-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.578-584
    • /
    • 2013
  • Vertical open display cases are widely used in shopping malls, supermarkets, or retail stores to sell frozen and refrigerated products. Open display cases use air curtains to maintain a reasonable temperature within the storage space, prevent insects from breaking in, and reduce energy usage. In this research, computational fluid dynamics was used to find the optimal condition for reducing energy by considering various conditions such as discharge speed or temperature of air curtains. Results of the study showed that the amount of energy consumed in the display cabinet is influenced by the discharge speed and temperature of the slots installed on the upper area and the amount of air supplied to the storage area inside the shelf. This shows that the amount of discharged air supplied from the storage area influences the formation of air curtain and also the amount of energy consumption. As a result of this study, we learned that the amount of energy used can be reduced by increasing the amount of discharged air within the storage area and enhancing back pressure.