• Title/Summary/Keyword: disc specimen

Search Result 105, Processing Time 0.024 seconds

Antioxidant, Antimicrobial and Anti-inflammatory of Mixed Medicinal Herb Extract (한약재 복합 추출물의 항산화, 항균 및 항염 효과)

  • Lee, In-Chul;Kim, Mee-Kyung
    • The Korea Journal of Herbology
    • /
    • v.30 no.5
    • /
    • pp.51-58
    • /
    • 2015
  • Objectives : This paper aimed to verify the applicability of mixed extract ofAngelica gigasNakai,Cnidium officinaleMakino,Paeoniala ctifloraPall,Rechmannia glutinosaLibosch,Scutellaria baicalensisGeorgi, which were prescribed for improving inflammation in Donguibogam, as the materials for beauty food and functional medicinal herb cosmetics by manufacturing such mixed extract and evaluating the biological activity of the extract.Methods : The mixed medicinal herb water extract(MMW) and ethanol extract(MME) were freeze-dried to be used as the specimen. We performed electron donating ability, lipid acidification inhibitory activity, anti-inflammatory activity against skin flora, MTT assay, NO inhibitory activity and the protein expression inhibitory activity of iNOS and COX-2.Results : For anti-oxidation experimentation, the electron donating abilities of MMW and MME were above 60.0% and 90.0% at 500 μg/ml, respectively. In the inhibition rate of lipid peroxidation, MMW and MME showed 43.1% and 52.1% at 1,000 μg/ml, respectively. As a result of antimicrobial activity, both the MMW and MME showed significant clear zones forPropionibacterium acnesat 4 mg/disc, but did not indicated the clearzones forStaphylococcus aureus, Escherichia coliandStaphylococcus epidermidis. Anti-inflammatory activity by NO assay showed LPS-induced NO was significantly inhibited in a concentration-dependent manner. Also, the expression of iNOS and COX-2 proteins were significantly inhibited following treatment with MMW and MME of 50 μg/ml.Conclusions : Accordingly, it can be concluded that mixed medicinal herb extract has the potential to beused as a functional food and cosmetic material.

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

The Development of a Non-Linear Finite Element Model for Ductile Fracture Analysis - For Mini-Computer - (연성파괴 해석을 위한 비선형 유한요소 모델의 개발 -소형 컴퓨터를 위한 -)

  • 정세희;조규종
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.25-33
    • /
    • 1986
  • In this paper, the frontal method based elastic-plastic F.E.M. program for mini-computer was developed. Since, the executable source program size was restricted by the system core memory size on the mini-computer, the active variables were memorized by the element base and the nonactive varables were memorized to the external disc file. The active variables of the finally developed program were reduced enough to execute about 1,000 freedom finite element on the mini-computer on which available variables were restricted as 32,767 integers. A modified CT fracture test specimen was examined to test the developed program. The calculated results were compared with experimental results concerning on the crack tip plastic deformation zone. Recrystallization technique was adopted to visualize the intensive plastic deformation regions. The Von-Mises criterion based calculation results were well agreed with the experimental results in the intensive plastic region which was over than 2% offset strain. The F.E.M. results using the developed program were well agreed with the theoritical plastic boundary which was calculated by the stress intensity factor as r$_{p}$=(K$_{1}$$^{2}$/2.pi..sigma.$_{y}$$^{2}$).f(.theta.).).).

New Record of the Deepwater Stingray Plesiobatis daviesi from Korea (한국산 긴꼬리흰가오리과 (Plesiobatididae) 어류 1미기록종, Plesiobatis daviesi)

  • Kim, Byeong Yeob;Kim, Maeng Jin;Song, Choon Bok
    • Korean Journal of Ichthyology
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2016
  • A single specimen (700 mm in disc length) of Plesiobatis daviesi, belonging to the family Plesiobatididae, was firstly collected in the north-eastern coastal waters of Jejudo Island, Korea by using a bottom trawl on 24 October 2010. This species was characterized by having five pairs of gill openings, tail with one to three large spines, long snout length, long caudal fin, and pleated margin of nasal curtain. It is morphologically similar to Urolophus aurantiacus, but the former is distinguished from the latter by having longer caudal fin and snout length. We add P. daviesi to the Korean fish fauna and suggest the new Korean names, "Gin-kko-ri-huin-ga-o-ri-gwa", "Gin-kko-ri-huin-ga-o-ri-sok" and "Gin-kko-ri-huin-ga-o-ri" for the family, genus and species, respectively.

Thoracoscopic Discectomy of the Herniated Thoracic Discs (흉추 추간판 탈출증에서 흉강경하 흉추간판 절제술)

  • Lee, Sang Ho;Lim, Sang Rak;Lee, Ho Yeon;Jeon, Sang Hyeop;Han, Young Mi;Jung, Byung Joo
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1577-1583
    • /
    • 2000
  • Objectives : Among the various types of minimally invasive spine surgeries, thoracoscopic surgery is becoming more widely accepted and increasingly utilized. This report delineates our clinical experience using thoracoscopy to resect herniated thoracic discs in 16 patients who suffered from myelopathy or intolerable radiculopathy. Patients and Methods : Between Mar. 1997 and Sep. 1999, 16 consecutive patients underwent thoracoscopic discectomy for treatment of herniated thoracic discs. There were 12 men and 4 women(mean age 43.5 years ; range 18-61 years). Eleven patients presented with myelopathic signs and symptoms from spinal cord compression and 5 patients had incapacitating thoracic radicular pain without myelopathy. The surgical level was varied between T3 and T12. The pathology of specimen were 11 hard discs and 5 soft discs herniations. Thoracoscopic techniques were performed with long narrow spine instruments and high speed drill through 3 or 4 ports under one lung ventilated general anesthesia. During the operation three patients were converted to open thoracotomy due to intolerable one lung ventilation, excessive bleeding and inadequate operation field. The mean operation time was 264min.(range : 100-420min.), and postoperative mean admission period was 11 days. Results : Clinical and neurological outcomes were good in all patients(mean follow-up period 20 months). Among the eleven myelopathic patients, 8 improved neurologically, and 3 stabilized. Among the five radiculopathic patients, 4 recovered completely and no patient had worsened. Postoperative complications were pleural effusion in one case, intercostal neuralgia in one, delayed hemopneumothorax in one, prolonged air leakage in one and pneumonia in one case. Conclusions : Thoracoscopic discectomy needs a steep learning curve to be familiar to anatomical space and handling of endoscopic instruments. However, it is technically feasible and can be effectively performed with acceptable results.

  • PDF

A STUDY ON THE STAINING TENDENCY OF ETHETIC RESTORATIVE MATERIALS (심미성 수복재료의 착생경향에 관한 연구)

  • Shin, Heung-Soo;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.372-383
    • /
    • 1995
  • The staining tendency of esthetic restorative material was very important factor for the people who are great concern about the esthetics. Most external stains were superficial and adjustable by routine prophylactic procedure. But some of these stains were remained under superficial stain. Some of these stains were accumulative on external tooth surface and it's removal alter the anatomic contour of restoration. The purpose of this study was to evaluate and compare the staining tendency of esthetic restorative materials to staining solution. In this study two glass-ionomer cements (Fuji II Glass-Ionomer Cement and Fuji II LC Glass-Ionomer Cement) and three composite resins (Sil$\ddot{u}$x Plus, APH and P-50) were evaluated and compared. Total 8 disc-shaped specimens of each material (17mm diameter, Imm thick) were immersed in coffee staining solution. These specimens were divided into one control and 3 experimental groups according to the immersion period as follows : Control: immersed in distilled water during each testing period Group 1 : immersed in staining solution for 6 hours Group 2 : immersed in staining solution for 24 hours Group 3 : immersed in staining solution for 72 hours Staining tendency was evaluated by total color difference(${\Delta}E^*$) of specimen before and after staining by spectorcolorimeteric readings (ColorQUEST Spectrophotometer, U.SA.). The results were as follows : 1. The total color differences of each testing materials were increased with time. 2. Among the experimental groups, the Fuji II Glass Ionomer Cement showed the highest total color difference(6.803) and the Silux Plus showed the lowest total color difference(1.637). 3. In comparison of glass ionomer cements, the total color difference of chemical cured glass ionomer cements(6.803) were higher than light cured glass ionomer cements(3.891) (P<0.01). 4. In comparison of composite resins, the P-50 showed the highest total color difference and the Silux Plus showed the lowest total color difference, but there was not significant difference among composite resins(P>0.05).

  • PDF

Damage Monitoring of Rolling Contact Fatigue in Wheel Specimen for High Speed Train Using Electro-Magnetic Sensor (전자기센서를 이용한 고속철도용 차륜재의 구름접촉피로 손상 모니터링)

  • Kwon, Seok-Jin;Hwang, Ji-Sung;Seo, Jung-Won;Lee, Jin-Yi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.600-606
    • /
    • 2012
  • Upon investigation of the damaged wheels for high speed train it was determined that the damage was caused by rolling contact fatigue during operation of train. The major problems that railway vehicle system using wheel-rail has to face during operation of railway vehicle are rolling contact fatigue, cracks in wheels, cracks in rails and wheel-rail profile wear. If these deficiencies are not controlled at early stages the huge economical problems due to unexpected maintenance cost in railway vehicle can be happened. Also, If the accurate knowledge of contact conditions between wheel and rail can be evaluated, the damage of wheel can be prevented and the maintenance operation can save money. This paper presents the applicability of electro-magnetic technique to the detection and sizing of defects in wheel. Under the condition of continuous rolling contact fatigue the damage of wheel has continuously monitored using the applied sensor. It was shown that the usefulness of the applied sensor was verified by twin disc test and the measured damaged sizes showed good agreement with the damaged sizes estimated by electro-magnetic technique.

Microstructure Characterization of Nb-Si-B alloys Prepared by Spark Plasma Sintering Process (방전 플라즈마 소결(Spark Plasma Sintering) 방법에 의해 제조된 Nb-Si-B계 합금의 미세조직 특성)

  • Kim, Sang-Hwan;Kim, Nam-Woo;Jeong, Young-Keun;Oh, Sung-Tag;Kim, Young Do;Lee, Seong;Suk, Myung Jin
    • Journal of Powder Materials
    • /
    • v.22 no.6
    • /
    • pp.426-431
    • /
    • 2015
  • Microstructural examination of the Nb-Si-B alloys at Nb-rich compositions is performed. The Nb-rich corner of the Nb-Si-B system is favorable in that the constituent phases are Nb (ductile and tough phase with high melting temperature) and $T_2$ phase (very hard intermetallic compound with favorable oxidation resistance) which are good combination for high temperature structural materials. The samples containing compositions near Nb-rich corner of the Nb-Si-B ternary system are prepared by spark plasma sintering (SPS) process using $T_2$ and Nb powders. $T_2$ bulk phase is made in arc furnace by melting the Nb slug and the Si-B powder compact. The $T_2$ bulk phase was subsequently ball-milled to powders. SPS is performed at $1300^{\circ}C$ and $1400^{\circ}C$, depending on the composition, under 30 MPa for 600s, to produce disc-shaped specimen with 15 mm in diameter and 3 mm high. Hardness tests (Rockwell A-scale and micro Vickers) are carried out to estimate the mechanical property.

A study on the Powder Injection Molding of Translucent Alumina via Flowability Simulation of Powder/Binder Mixture (분말사출성형 시 분말 혼합체의 유동성 시뮬레이션을 통한 투광성 알루미나 소결체의 특성 연구)

  • Kim, Hyung Soo;Byun, Jong Min;Kim, Se Hoon;Kim, Young Do
    • Journal of Powder Materials
    • /
    • v.21 no.3
    • /
    • pp.215-221
    • /
    • 2014
  • Translucent alumina is a potential candidate for high temperature application as a replacement of the glass or polymer. Recently, due to the increasing demand of high power light emitting diode (LED), there is a growing interest in the translucent alumina. Since the translucent property is very sensitive to the internal defect, such as voids inside or abnormal grain growth of sintered alumina, it is important to fabricate the defect-free product through the fabrication process. Powder injection molding (PIM) has been commonly applied for the fabrication of complex shaped products. Among the many parameters of PIM, the flowability of powder/binder mixture becomes more significant especially for the shape of the cavity with thin thickness. Two different positions of the gate were applied during PIM using the disc type of die. The binder was removed by solvent extraction method and the brown compact was sintered at $1750^{\circ}C$ for 3 hours in a vacuum. The flowability was also simulated using moldflow (MPI 6.0) with two different types of gate. The effect of the flowability of powder/binder mixture on the microstructure of the sintered specimen was studied with the analysis of the simulation result.