• Title/Summary/Keyword: disc hole

Search Result 49, Processing Time 0.033 seconds

Ablation Characteristic Study for Carbon Fabric/EPDM Chamber Insulation (Carbon Fabric을 삽입한 EPDM계 연소관 내열재 삭마 특성 연구)

  • Kim, Jin-Yong;Choi, Ji-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Hahm, Hee-Cheol;Yun, Nam-Gyun;Rhee, Young-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • We developed the carbon fabric/EPDM chamber insulation in order to protect motor case with high intensity gas flow. A six-inch simulation motor connected with extension tube was designed to test ablation characteristic of insulation. High intensity gas flow was induced by a FRP disc with hole between motor and extension tube. After ground test, ablation depth of the carbon fabric/EPDM insulation was decreased compared to another insulations after ground static test.

Ablation Characteristic Study for Carbon Fabric/EPDM Chamber Insulation (Carbon Fabric을 삽입한 EPDM계 연소관 내열재 삭마 특성 연구)

  • Kim, Jin-Yong;Choi, Ji-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Ham, Hee-Cheol;Yun, Nam-Gyun;Rhee, Young-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.85-91
    • /
    • 2011
  • We developed carbon fabric/EPDM chamber insulation in order to protect motor case with high intensity gas flow. Six-inch simulation motor connected with extension tube was designed to test ablation characteristic of insulation. High intensity gas flow was induced by FRP disc with hole between motor and extension tube. After ground test, ablation depth of carbon fabric/EPDM insulation was decreased compared to another insulations after ground static test.

  • PDF

A STUDY OF SURFACE ROUGHNESS OF COMPOSITE RESIN (복합레진의 표면조도에 관한 연구)

  • Park, Ki-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.108-115
    • /
    • 2000
  • This study was designed to compare the effect of polishing on surface roughness of composite resin. We used Z100(3M) composite resin and placed the composite resin in the hole (4mm thick and 4mm in diameter) of vinyl plate and polymerized it under manufacturer's instructions. Samples were divided into 5 groups by polishing methods. Group 1 was control: resin was polymerized under glass plate, Group 2: resin was polymerized without any polishing procedure, Group 3: resin was polymerized with a polishing procedure of abrasive disc, Group 4: bonding agent was applyed in thin layer and polymerized on the polished polymerized resin surface. Group 5: resin was polymerized under transparent celluloid strip. The surface roughness of each specimen was measured with Sufacoder SEF-30D (Kosaka lab. Ltd) under 0.08mm cut off, 0.05mm/s stylus speed, ${\times}40$ horizontal magnification, ${\times}5000$ vertical magnification. The results were as follows : 1. Group 1 showed the most smooth surface in this study. 2. Group 3 showed more rough surface than Group 2. Considering the surface roughness, it would be better to make the shape completely before polymerize the resin. To finish and polish after the polymerization of resin makes less smooth surface. 3. When we use the transparent celluloid strip, minimum finishing procedures are recommended. Any polishing procedure could not recover the smooth resin surface of celluloid strip. 4. Application and polymerization of the thin layer of bonding agent on the polished surface showed the minimum surface smoothing effect.

  • PDF

A Study for Improvement of Cornering Fatigue Test by Eliminating a Fretting Effect on Steel Wheel to enhance Durability and Reliability (스틸 휠 굽힘 모멘트 내구시험의 내구신뢰성 개선에 대한 연구 - 스틸 휠 접촉면의 프랫팅 제거 -)

  • Chung, Soo-Sik;Jung, Won-Wook;Yoo, Yeon-Sang;Kang, Woo-Jong;Kim, Dae-Sung;Kwon, Il-Ki
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1326-1330
    • /
    • 2008
  • The failure mode of steel road wheels in a vehicle is cracks from ventilation hole through to contact plane on steel wheel's disc plate. But a number of cracks of Cornering Fatigue Limit Test is on contact plane near to wheel nut mounting area, even though it's satisfied with specified cycles. So this paper searches out causes to improve durability and reliability of C.F.T by uni-axial bending moment test. The verified cause is a "fretting" on contact area of steel wheel. In result, this paper suggests a solution to prevent a fretting by inserting a damping shim, 0.7mm between steel wheel contact areas. Therefore this paper makes it possible to move crack position of C.F.T in steel wheel from contact plane to vehicle's failure mode.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF LINK PLUS PIN IN DENTIN (상아질에 장착된 Link plus pin의 주사전자현미경적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.205-210
    • /
    • 1989
  • The purpose of this study was to observe the minim pins of Link plus (which has buttress thread and shoulder stop design) inserted into dentin and the dentin surrounding pin. The gingival walls of class II cavity were prepared with high speed handpiece in molar teeth not elapsed time after teeth were extracted, and pinhole of 2mm in depth was positioned about 1 mm to the dentinoenamel junction and minim pin was inserted with wrench. After initial examination of the specimens, the specimens were sectioned longitudinally and horizontally to the pins with carborundum disc and low speed diamond saw (Isomet Buehler Ltd) All specimens were coated Au of 250-300${\AA}$ in thickness with Ion Sputter JFC 100 and observed under Scanning Electron Microscope (JSM-35) The following results were obtained. 1. The shoulder stop was seated on the enterance of pinhole in gingival wall, and there were the irregular space between the pin and dentin at the enterance to the pin hole and flakes of dentin lifting from the dentin floor. 2. In case of section to pin horizontally or longitudinally, the dentin debris were observed in gap between pin and dentin, and small cracks were often seen in the dentin surrounding minim pins.

  • PDF

A Convergent Investigation on Structural Analysis with Thermal Stress at the Shape of Brake Disk for Racing Car (경주용 자동차 브레이크 디스크 형상에서의 열 응력 및 구조 해석에 관한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.6
    • /
    • pp.209-213
    • /
    • 2020
  • In this study, the model A with the existing shape used at racing car and the model B with light weight were designed. The structural analysis with thermal deformation and stress were carried out. Model A shows that the maximum temperature is lower than model B. The cooling performance due to the shape of the disk without any other cooling conditions can be shown to be better for model A. Model A was seen to be superior in durability as the thermal stress reduced by almost twice as much as model B. The part where the greatest stress occurred appeared to be the hole jointed with the hub regardless of its shape. The analysis results at this study are seen to be useful at designing the shape of the actual vehicle brake disc. The analysis results obtained in this study can be applied at grasping the strength of the brake disk for racing car practically. By utilizing the analysis result of the brake disk for racing car, this study is seen as the convergence study that the aesthetic design and analysis are applied.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Anterior Cervical Microforaminotomy : A Minimally Invasive Anterolateral Approach for Spondylotic Lesions (전방 경추 미세 추간공 확대술 : 경추증에 대한 최소침습적 전측방 접근법)

  • Park, Sung-Jin;Ha, Ho-Gyun;Jung, Ho;Lee, Sang-Keol;Park, Moon-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.87-94
    • /
    • 2000
  • Objective : Various surgical approaches have been implemented to fulfill the ideal goals of treatment for cervical spondylotic lesions. Conventional approaches are represented by anterior approach with or without fusion and posterior approach. The authors has applied newly developed anterior cervical microforaminotomy for these lesions on minimally invasive basis. Materials and Method : Twenty-one patients, with cervical HIVD, or stenosis, or both, underwent anterior cervical microforaminotomy between March, 1998 and April, 1999. Fifteen patients underwent unilateral decompression, and 6 bilateral decompression via unilateral foraminotomy. Operation of one level was performed in 16 patients, 2 levels in 4 patients, and 3 in 1 patient. The foraminotomy was accomplished by resecting the uncovertebral joint. Through this hole, compressed nerve root was decompressed by removing the spondylotic spur or disc fragment, and diagonal removing of posterior osteophyte from foraminotomy site to begining of contralateral nerve root made spinal cord decompression. Results : The outcome was excellent in 17 patients(81%) and good in 4 patients(19%) based on Odom's criteria. No complication was encounterd, and average post-operation hospital stay was 3.7 days. Conclusions : These results indicate that anterior cervical microforaminotomy provide adequate neural decompression, minimum postoperative discomfort and fast recovery.

  • PDF

A Design of Chemical Analysis for the CD-R Recording Layer's Nano-structure and Composition Analysis (CD-R 기록층의 나노구조 및 성분 분석을 위한 화학분석 설계 사례)

  • Cho, Namjun
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.2
    • /
    • pp.84-90
    • /
    • 2012
  • It is described that the total analysis of CD-R, a digital recording media, including the planning and performing chemical analysis of cross sectional structure of recording layer, dye composition and chemical structure as an example of design for chemical analysis. Since chemical analysis of unknown sample is often involved the complicated process requiring many experiences and knowledge, students feel difficulties in planning the procedure of chemical analysis and selecting analytical methods. Thus, an example of chemical analysis is provided here to help student understanding the hole procedure of CD-R analysis. In this study, SEM is used to determine the cross sectional structure of PC substrate and recoding layer of CD-R. The dyes in recording layer is dissolved with solvent and separated with using TLC, analyzed with using UV-Vis absorption spectrometer. Then, the chemical structure of each component is determined with using GC-MS, NMR and mass spectrometer.

  • PDF