• Title/Summary/Keyword: disaster protection and safety management

Search Result 141, Processing Time 0.021 seconds

Safety Measure Developed Through Analysis of Firefighters' 『Investigation Report on Accidents to On-Site Workers』

  • Jo, Chang-Hyun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.334-344
    • /
    • 2021
  • The study has suggested a way to minimize safety accidents found in on-site firefighting activity by analyzing firefighters' [investigation report on accidents to on-sie workers]. The study result is described as follows. First, the result of [investigation report on on-site workers] shows that while accidents are found to most frequently have occurred to low-ranking firefighting officers such as Sobangsa and Sobanggyo and firefighting officers with career of less than 5 years, fire-extinguishing activity proved to be the most prone to accidents in the category of activity. Second, analysis performed to identify variance between injury extent and area based on cause of accident shows statistically significant variance. In addition, the result of verifying difference in cause of accident based on category of activity shows significant difference with 'falling over and sliding' being the highly likely cause of accident in fire containment and rescue activities and 'reckless move' being highly likely case of accident in emergency activities. Third, the result of verifying factors behind the extent of injury done to on-site workers shows that when accident is caused by 'incomplete behavior', it was found that the extent of injury is substantial. It was also found that rescue activity is accompanied by substantial extent of injury. As a solution to this, the study suggested ways to establish, extend and operate safety-specific curriculum for entrants, develop materials regarding risk prognosis training and explicate training-related regulations, set up safety management measure for a single squad team, upgrade performance of private protection equipment, institutionalize SOP by on-site activity stage, materialize and activate swift rescue team and increase objectivity and proficiency of safety accident investigation.

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Case Study on the Analysis of Disaster Vulnerabilities (Focused on the Fire & Explosion in the N-Industrial Complex) (재난 취약성 분석에 관한 사례연구(N공단의 화재·폭발을 중심으로))

  • Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.94-100
    • /
    • 2021
  • In general, the industrial complex is a place where factories of various industries are concentrated. It is only as efficient as it is designed. However, the risks vary as there are various industries. These features are also associated with various types of disasters. The dangers of natural disasters such as a typhoon, flood, and earthquake, as well as fire and explosions, are also latent. Many of these risks can make stable production and business activities difficult, resulting in massive direct and indirect damage. In particular, decades after its establishment, the vulnerabilities increase even more as aging and small businesses are considered. In this sense, it is significant to assess the vulnerability of the industrial complex. Thus analysing fire and explosion hazards as stage 1 of the vulnerability evaluation for the major potential disasters for the industrial complex. First, fire vulnerabilities were analyzed quantitatively. It is displayed in blocks for each company. The assessment block status and the fire vulnerability rating status were conducted by applying the five-step criteria. Level A is the highest potential risk step and E is the lowest step. Level A was 11.8% in 20 blocks, level B was 22.5% in 38 blocks, level C was 25.4% in 43 blocks, level D was 26.0% in 44 blocks, and level E was 14.2% in 24 blocks. Levels A and B with high fire vulnerabilities were analyzed at 34.3%. Secondly, the vulnerability for an explosion was quantitatively analyzed. Explosive vulnerabilities were analyzed at 4.7% for level A with 8 blocks, 3.0% for level B with 5, 1.8% for level C with 3, 4.7% for level D with 8, and 85.8% for level E with 145. Levels A and B, which are highly vulnerable to explosions, were 7.7 %. Thirdly, the overall vulnerability can be assessed by adding disaster vulnerabilities to make future assessments. Moreover, it can also assist in efficient safety and disaster management by visually mapping quantified data. This will also be used for the integrated control center of the N-Industrial Complex, which is currently being installed.

A Study on Toxicity Bio-markers of a Mouse using Combustion Gas SO2 generated from Fire (마우스(mouse)를 이용한 건축물 마감재료 연소가스 SO2의 독성생체지표 연구)

  • Rie, Dong-Ho;Cho, Nam-Wook;Choi, Soon-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • This study was carried out to observe the impacts of a mouse's inhalation of toxic gas SO2 generated from combustion on its organs by different concentrations. As for research methods: First, after concentrations of SO2 generation from combustion had been set to three: low (10.4 ppm), middle (24.9 ppm) and high (122 ppm) through Gas Toxicity Testing Method (KS F 2271) and SO2 combustion gas was exposed to eight mice in each concentration. Five mice that were able to move based on LD50, a criterion, which sets the down time of a mouse's average behaviors to over 9 minutes, were randomly selected in each concentration, and they were set up as the subjects of the study on toxicity bio-markers. Second, tissues were taken from heart, liver, lungs, spleen and the thymus gland of the mice selected in each concentration and a pathological examination of them was carried out. As a result, microvascular congestion appeared in the heart, and cell necrosis, cortex congestion and tubule medulla congestion, etc. in each concentration were observed in addition to vascular congestion in liver, lungs, spleen and the thymus gland. Also, it was found that the higher the concentrations of SO2 exposure is, the greater, the changes in the organs get. Through this study, SO2 of various toxic gases generated from fire turned out to affect the tissues of each organ of a mouse, it is expected that the toxic gases may greatly affect human body in case of actual fire, and this study is evaluated as having a significance as a basic data on inhalation toxicity assessment of toxic substances generated in combustion.

A Study on the Legislation Directions of FRAMEWORK ACT ON KOREA COAST GUARD(tentative name) ((가칭) 해양경찰기본법 입법방향에 관한 연구)

  • Son, Yeongtae
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.396-407
    • /
    • 2014
  • In 19th May 2014, the government announced that KCG(Korea Coast Guard) is dissolved regarding responsibility for recently accident which is Sewol ferry disaster. But KCG, a central administrative agency is responsible for protecting maritime sovereignty of South Korea; the most basic and indispensable organization. Furthermore, The purpose of KCG is to provide the safety of the public and keeping of public order by prescribing matters necessary for the securement of maritime security, maintenance of public order and protection of marine resources & facilities. Therefore, In this article, I would like to suggest tentatively named FRAMEWORK ACT ON KOREA COAST GUARD's management plan which could reflect the scope of functions. It means we examine the current state of KCG, and would like to signpost for the most ideal way of legal system in Korea Coast Guard. Finally, this treatise is expected that this research can be a guideline contribute to improving Korea Coast Guard relevant laws even a little.

Improvement Plan for Safety Management of the Transport of Railway Dangerous Goods (철도 위험물 수송 안전관리제도 개선 방안)

  • Sung-Bong Chung;Bong-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.885-895
    • /
    • 2024
  • As the lack of management for HAZMAT transportation leads to fatal accidents, the interest in the problem is rapidly increasing in the world. Thus UN-RTDG recommends to establish regulations for HAZMAT transportation, and related ministries in Korea make rules and policies according to the regulations. However, there are few researches carried out on railway HAZMAT transportation. In this paper, issues such as present condition of laws and policies related to railway HAZMAT transportation, HAZMAT transportation procedure and regulations, HAZMAT signs of railway etc. are analyzed. Through analyzing these issues the problems and improvements of railway HAZMAT transportation are drawn. These results are respected to help to establish regulations and policies for HAZMAT transportation management. In the future, more detailed plan is needed for putting these improvements to practices.

A Study on Risk Classification of Small Plant for Safe Management of Hazardous Chemicals (유해화학물질 안전관리를 위한 중소사업장의 위험도 분류에 관한 연구)

  • Lee, Hyo-Eun;Kim, Min-Gyu;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2021
  • Chemical accidents can happen anywhere in the world. To prevent chemical accidents, Korea introduced the Chemicals Control Act. However, Small and medium-sized businesses do not meet these regulations. Accordingly, the Ministry of Environment is providing a chemical safety management support project for Small and medium-sized businesses. However, there are many small and medium-sized businesses, and businesses that need support need priority. In this study, the risk of the plants was classified into hig h, medium, and low risk based on four methods. As a result, out of 90 plants subject to the study, high risk was 30% and medium risk was 70%. The industries with the high risk were chemical products manufacturing and paint manufacturing. The plating and printing industries showed relatively medium risk. This risk classification has the advantage that it can obtain intuitive and quick results. These studies can be used as basic data for chemical safety management of local governments and Ministry of Environment.

The A Test of Physical Property of Fire Extinguishing Agent according to Durable Years of the Third-class Powder Extinguisher (제3종 분말소화기의 내용연수에 따른 소화약제의 미세도 실험)

  • Ju-Dal, Son;Ha-Sung, Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.117-124
    • /
    • 2022
  • This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.