• Title/Summary/Keyword: direction of needle

Search Result 79, Processing Time 0.019 seconds

Evaluation on the Usefulness of Lung Tumor Stereotactic Radiosurgery Applying the CyberKnife $Synchrony^{TM}$ Respiratory Tracking System (사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치를 이용한 폐종양 방사선수술의 유용성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Choi, Jun-Gu;Chae, Hong-In
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.379-386
    • /
    • 2010
  • This study evaluated the motion of tumors during the entire period of therapy and the accuracy of radiosurgery among forty eight lung tumor patients who were underwent radiosurgery using the CyberKnife Synchrony Respiratory Tracking System. The motion of lung tumor was measured by the coordinates of a gold acupuncture needle inserted into the tumor or the area around the tumor using the CyberKnife image guided system. Then the accuracy of radiosurgery was evaluated based on the error of correlation computed with the motion tracking system. The lung tumor motion is Cranio-Caudal direction by an average of $2.63{\pm}1.87\;mm$, moved left-right direction by $1.13{\pm}0.71\;mm$, and anterior-posterior direction by $1.74{\pm}1.16\;mm$. The degree of rotational movement was $1.66{\pm}1.66^{\circ}$ on X axis, $1.20{\pm}0.97^{\circ}$ on Y axis, and $1.18{\pm}0.73^{\circ}$ on Z axis. The vector of translation movement was measured to be $3.78{\pm}2.00\;mm$ on the average. The results show that directions of Cranio-Caudal(p < 0.001), anterior-posterior direction(p < 0.029), and three dimensional vector value(p < 0.002) showed statistical significance, because the lower side of tumor showed more intensive movement compared to the upper side of tumor. The radiosurgery was carried out by compensating the motion of tumor after accurate investigation of the correlation error with the average of $0.95{\pm}0.62\;mm$ during the lung tumor radiosurgery with the CyberKnife Synchrony Respiratory Tracking System.

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

Retroperitoneal Hematoma after Trigger Point Injections of Quadratus Lumborum -A case report- (요방형근(Quadratus Lumborum) 통증 유발점 주사 후 나타난 후복막 혈종 -증례 보고-)

  • Shim, Jae-Yong;Park, Chong-Min;Bae, Man-Suck
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.263-267
    • /
    • 1999
  • We have observed retroperitoneal hematoma after trigger point injections of quadratus lumborum in a patient with chronic low back pain. Severe flank pain and dyspnea was observed three hours after injection of local anesthetic and steroid to the trigger point of quadratus lumborum muscle. There was fuge hematoma in abdominal CT image around the right kidney, which displaced and compressed the kidney anteriorly. Following infusion of contrast media, extravasation through renal vein and IVC was notified. Patient had a past history of having been treated with platelet aggregation inhibitor and lower dose aspirin treatment after cerebral ischemia for a year, but coagulative function was within normal range. Patient was admitted 12 days for bed rest, pain control and transfusion. We need to take greater care with a frequent aspiration and exact direction of needle, during trigger point injection of quadratus lumborum, particu right side, to avoid vascular injury.

  • PDF

EFFECT OF $SiF_4$ADDITION ON THE STRUCTURES OF SILICON FILMS DEPOSITED AT LOW TEMPERATURE BY REMOTE PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION

  • Xiaodong Li;Park, Young-Bae;Kim, Dong-Hwan;Rhee, Shi-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S2
    • /
    • pp.64-68
    • /
    • 1995
  • Silicon films were deposited at $430^{\circ}C$ by remote plasma chemical vapor deposition(RPECVD) with a gas mixture of $Si_2H_6/SiF_4/H_2$. The silicon films deposited without and with $SiF_4$ were characterized using atomic force microscopy(AFM), transmission electron microscopy(TEM) and X-ray diffraction(XRD). Both silicon films have the same rugged surface morphology, but, the silicon film deposited with $SiF_4$ exhibits more rugged. The silicon film deposited without $SiF_4$ is amorphous, whereas the silicon film deposited with $SiF_4$ is polycrystalline with very small needle-like grains which are perpendicular to the substrate and uniformly distributed in the thickness of the film. The silicon film deposited with $SiF_4$ was found to have a preferred orientation along the growth direction with the<110> of the film parallel to the <111> of the substrate. The effect of $SiF_4$ during RPECVD was discussed.

  • PDF

Effects of Mo on the Microstructure and Hardness in High Chromium Cast Irons (Mo가 고크롬주철의 조직 및 경도에 미치는 영향)

  • Yu, Sung-Kon
    • Journal of Korea Foundry Society
    • /
    • v.16 no.2
    • /
    • pp.141-148
    • /
    • 1996
  • In high chromium cast iron, the control of matrix microstructure as well as carbide structure is important to the performance as a wear resistant material. In this study, 3.0% C-24.0% Cr white cast irons with various molybdenum contents(residual, 1.0%, 3.0% and 5.0%) were solidified conventionally and unidirectionally for studying their effects on the microstructure and hardness. In the conventional casting, two sets of castings were poured from each melt. One set of the castings consisted of cylindrical bars of 10 and 20mm by 155mm long. The second set of the castings was a cylindrical bar of 30mm by 200mm long. On the other hand, a pep-set mold set on the Cu plate was employed to make the solidification unidirectionally. X-ray diffraction method was used to observe retained austenite and carbides in the high chromium cast iron. The morphology of eutectic $M_7C_3$ carbides changed from needle-like type to nodular type with the increase of Mo content. And, the presence of $M_2C$ carbides was identified in the sample where Mo was added over 3.0 %. Primary and eutectic carbides appeared as rod type and corngrain type, respectively in the unidirectionally solidified samples which were cut to parallel to the solidification direction. In the EDX analysis, Cr concentration was higher in the primary and eutectic $M_7C_3$ carbides, Mo in the $M_2C$ carbides, and Fe in the matrix.

  • PDF

The Development of Microwave Tissue Coagulator (마이크로파를 이용한 수술기의 개발)

  • Park, B.W.;Jeong, B.S.;Park, Mi-Gnon;Lee, S.B.;Son, W.J.;Jeong, D.G.;Yang, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.81-83
    • /
    • 1989
  • In surgery the hemostatic control is very important for the parenchymatous organs. These organs consist of the fragile and the blood content tissues such as liver, spleen and kidney, etc.. One of the control methods to solve this problem is to insert the mono polar typed needle electrode, which gathers the thermal effect of microwave, directly into tissues so as to coagulate and stop the hemorrhage. This method has same advantages: First, the range of the heat energy is limited. Second, the coagulation, the hemostatic characteristic, and stability are excellent. Third, more convenient operation is possible. This paper is aimed to manufacture the microwave tissue coagulation system and to suggest the new direction for development, hereafter.

  • PDF

Acupuncture Treatment in Clinical Studies for Parkinson's Disease : A Literature Review

  • Sohn, Soo Ah;Lee, Kyoung Yun;Kim, Chang Wan;Lee, Yu Jin
    • Journal of Acupuncture Research
    • /
    • v.35 no.4
    • /
    • pp.149-157
    • /
    • 2018
  • Background: Parkinson's disease is the second most common degenerative brain disease after Alzheimer's disease. This study reviewed clinical practice of acupuncture and moxibustion treatment for Parkinson's disease to assess the future direction of these treatments. Methods: The literature search used 5 Korean Internet databases. The search terms were "Parkinson's disease." and "Parkinson (Korean)." 36 papers were selected: 27 case reports, 2 respropective studies, 3 uncontrolled clinical trials, 3 randomized controlled trial, 1 non-randomized controlled trial. Results: Filiform needles were used in most of studies. Pharmacopuncture, electro-acupuncture, and auricular acupuncture therapy were also used in combination with Filiform needles. 2. The most commonly used basic acupoints for Parkinson's disease was Saamchimbeop. The most commonly used form of pharmacopuncture involved Bee-venom. Conclusion: It is expected that treatment of Parkinson's disease with a variety of acupuncture and moxibustion therapies will continue to be studied, in addition to treatments that utilize existing Filiform needle treatments in clinical practice.

Analysis of Fluid Flow Characteristics Around Rolling Element in Ball Bearings (볼 베어링의 구름 요소 주위 유동 특성에 대한 해석)

  • Jo, Jun Hyeon;Kim, Choong Hyun
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.278-282
    • /
    • 2012
  • Various bearings such as deep-groove ball bearings, angular-contact ball bearings, and roller bearings are used to support the load and to lubricate between the shaft and the housing. The bearings of potential rolling systems in a turbo pump are the deep-groove ball bearings as comparing with the bearings with rolling elements such as cylindrical rollers, tapered cylindrical rollers, and needle rollers. The deep-groove ball bearings consist of rolling elements, an inner raceway, an outer raceway and a retainer that maintain separation and help to lubricate the rolling element that is rotating in the raceways. In the case of water-lubricated ball bearings, however, fluid friction between the ball and raceways is affected by the entry direction of flow, rotation speed, and flow rate. In addition, this friction is the key factor affecting the bearing life cycles and reliability. In this paper, the characteristics of flow conditions corresponding to a deep-groove ball bearing are investigated numerically, with particular focus on the friction distribution on the rolling element, in order to extend the analysis to the area that experiences solid friction. A simple analysis model of fluid flow inside the water-lubricated ball bearing is analyzed with CFD, and the flow characteristics at high rotation speeds are presented.

Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System (자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가)

  • Kim, Soo-Byeong;Park, Sun-Woo;Ahn, Soon-Jae;Lee, Na-Ra;Lee, Seung-Wook;Min, Se-Eun;Kim, Young-Ho;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.

Analysis on Composition and Strength of Lime-Soil Mixture Barrier Tombs at Guri Galmae Site in Joseon Dynasty (조선시대 구리 갈매유적 회곽묘의 조성 및 강도분석)

  • Lee, Chan Hee;Eo, Eon Il;Shin, Sook Chung
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.2
    • /
    • pp.40-61
    • /
    • 2017
  • This study investigated material characteristics of composition and variable strength measurement using physicochemical and petrographic analysis for lime-soil mixture barrier tombs of Guri Galmae site in Joseon Dynasty. The tomb barriers are composed mainly of microcrystalline calcite, quartz, feldspar and mica with lime matrix. The lime matrix shows compact sheet texture, and some samples show hydration aggregates with needle-shaped textures. Gypsum occurred as a secondary process where carbonization reactions were poor. Concentrations of CaO in the tomb barrier very widely ranged from 4.43 to 36.19 wt.%, specific gravity and absorption ratio of the materials show of 1.35 to 1.62 and 20.1 to 32.6%, respectively. As the rebound hardness, the materials ranged from 10.0 to 28.4 (mean 15.7). The values are higher in the $-90^{\circ}$ direction rather than in the $0^{\circ}$ direction with the consequence that the values indicate more strength toward the vertical direction. Difference in strength by directions was caused by the directions of the tomb barriers, which is related to the processes in each stage. In the tomb barriers, ultrasonic velocity and unconfined compressive strength ranged from 1,049.2 to 1,728.9m/s and under 5.00MPa, respectively. Variation patterns between the two are very similar in values. As the result of composition and strength, the materials of higher contents on CaO are higher in strength values. Generally, techniques and skills to make the lime-soil mixture barriers are interpreted as low qualities in relatively.