• Title/Summary/Keyword: direct system

Search Result 6,832, Processing Time 0.039 seconds

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Characteristics of Rice and Paddy Soil under No-Till Direct-Sown Rice-Wheat Cropping System

  • Cho, Young-Son;Choe, Zhin-Ryong;Lee, Byeong-Zhin
    • Korean Journal of Organic Agriculture
    • /
    • v.7 no.2
    • /
    • pp.153-161
    • /
    • 1999
  • No-till direct-sown rice-wheat relaying cropping system has major advantages such as labor and cost saving by eliminating tillage and preparation of seed bed and transplanting. In this system, rice sowing was done simultaneously wheat harvesting. A paddy field experiment was conducted to evaluate effects of no-till years on soil microbial changes and soil physico-chemical characteristics with rice growth and development. Chemical fertilizers and agricultrual chemicals was not applied in no-till system. As the year in no-till direct-sown system the air permeability was increased and after water submerging soluble nitrogen was released Aerobic microbial-n was highest in May and then decreased after water irrigation. The population of aerobic soil microorganisms were steeply decreased after water submerging Soil microorganisms was decreased with the increased the soil depth. A month was needed for the seedling establishment in a no-tillage rice-wheat cropping system. Increased cropping years improved leaf greenness and leaf area index(LAI). But stomatal conductance(Gc) was higher in conventional cultivation system than no-till system. Stomatal conductance at panicle initiation stage was increased higher in conventional condition of leaves but the difference between conventional and no-till system was increased at heading stage. In no-till 4 years condition rice grain yield was spikelet numbers per panicle.

  • PDF

A study on the intelligent control of chaotic nonlinear systems using neural networks (신경 회로망을 이용한 혼돈 비선형 시스템의 지능 제어에 관한 연구)

  • 오기훈;주진만;박진배;최윤호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.453-456
    • /
    • 1996
  • In this paper, the direct adaptive control using neural networks is presented for the control of chaotic nonlinear systems. The direct adaptive control method has an advantage that the additional system identification procedure is not necessary. In order to evaluate the performance of our controller design method, two direct adaptive control methods are applied to a Duffing's equation and a Lorenz equation which are continuous-time chaotic systems. Our simulation results show the effectiveness of the controllers.

  • PDF

A Study on Recoil Force Reduction Using a Low-recoil Direct Gun (저반동 전차포의 주퇴력 저감 연구)

  • Park, Jin-Saeng
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.125-130
    • /
    • 2016
  • A low-recoil direct gun is useful in reducing the fire impulse generated by using a traditional shell. To apply a control equation to an AMESim Model, we have formulated a control equation for a recoil mechanism from the free object diagram. By modeling this equation, we have been able to compare the recoil distance and recoil force of a low-recoil direct gun. Here, we can analyze the recoil characteristics between traditional direct guns and low-recoil direct guns with perforated muzzle brakes. It is possible to mount a low-recoil direct gun with a perforated muzzle brake on a lightweight tracked vehicle by reducing its fire impulse.

Direct tracking of noncircular sources for multiple arrays via improved unscented particle filter method

  • Yang Qian;Xinlei Shi;Haowei Zeng;Mushtaq Ahmad
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.394-403
    • /
    • 2023
  • Direct tracking problem of moving noncircular sources for multiple arrays is investigated in this study. Here, we propose an improved unscented particle filter (I-UPF) direct tracking method, which combines system proportional symmetry unscented particle filter and Markov Chain Monte Carlo (MCMC) algorithm. Noncircular sources can extend the dimension of sources matrix, and the direct tracking accuracy is improved. This method uses multiple arrays to receive sources. Firstly, set up a direct tracking model through consecutive time and Doppler information. Subsequently, based on the improved unscented particle filter algorithm, the proposed tracking model is to improve the direct tracking accuracy and reduce computational complexity. Simulation results show that the proposed improved unscented particle filter algorithm for noncircular sources has enhanced tracking accuracy than Markov Chain Monte Carlo unscented particle filter algorithm, Markov Chain Monte Carlo extended Kalman particle filter, and two-step tracking method.

Precise Speed Control of Direct Drive PMSM for the Cogging Torque Measurement System (코깅토크 측정장치 직접구동용 영구자석 동기전동기의 정밀속도 제어)

  • Park, Cheol-Hoon;Son, Young-Su;Ham, Sang-Yong;Kim, Byung-In;Yun, Dong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • Recently PMSM(Permanent magnet synchronous motor) are used for the various direct drive applications such as index table, telescope system and so on. Because the position/speed control performance of direct drive PMSM is directly affected by the torque ripple, there are lots of studies to reduce the cogging torque in the motor design stage. In order to verify the motor design, the reliable cogging torque measurement system is essentially required. The measured motor must be rotated in the constant speed under 1deg/sec so that the cogging torque profile is measured correctly. In this study, the cogging torque measurement system which uses the direct drive PMSM and the speed controller to rotate the measured motor in 0.1rpm(0.6deg/sec) has been developed. Simulink/xPC target was used for the controller and data acquisition system. Based on PI controller, DOB and AFC have been applied to eliminate the low frequency disturbances and the periodic speed ripple. The experimental results show the good performance of the speed regulation for the reference speed 0.1rpm and the reliable profile of the measured cogging torque by the developed speed controller.

A Single Transistor-Level Direct-Conversion Mixer for Low-Voltage Low-Power Multi-band Radios

  • Choi, Byoung-Gun;Hyun, Seok-Bong;Tak, Geum-Young;Lee, Hee-Tae;Park, Seong-Su;Park, Chul-Soon
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.579-584
    • /
    • 2005
  • A CMOS direct-conversion mixer with a single transistor-level topology is proposed in this paper. Since the single transistor-level topology needs smaller supply voltage than the conventional Gilbert-cell topology, the proposed mixer structure is suitable for a low power and highly integrated RF system-on-a-chip (SoC). The proposed direct-conversion mixer is designed for the multi-band ultra-wideband (UWB) system covering from 3 to 7 GHz. The conversion gain and input P1dB of the mixer are about 3 dB and -10 dBm, respectively, with multi-band RF signals. The mixer consumes 4.3 mA under a 1.8 V supply voltage.

  • PDF

Analysis of Compression Ignition Combustion in a Schnurle-Type Gasoline Engine - Comparison of performance between direct injection and port injection systems -

  • Kim, Seok-Woo;Moriyoshi, Yasuo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1451-1460
    • /
    • 2004
  • A two-stroke Schnurle-type gasoline engine was modified to enable compression-ignition in both the port fuel injection and the in-cylinder direct injection. Using the engine, examinations of compression-ignition operation and engine performance tests were carried out. The amount of the residual gas and the in-cylinder mixture conditions were controlled by varying the valve angle rate of the exhaust valve (VAR) and the injection timing for direct injection conditions. It was found that the direct injection system is superior to the port injection system in terms of exhaust gas emissions and thermal efficiency, and that almost the same operational region of compression-ignition at medium speeds and loads was attained. Some interesting combustion characteristics, such as a shorter combustion period in higher engine speed conditions, and factors for the onset of compression-ignition were also examined.

Direct Load Control Algorithm Based Locational and Electric Load Characteristics (지역적 특성과 부하특성을 고려한 직접부하제어 알고리즘)

  • Shin, Ho-Sung;Song, Kyung-Bin;Moon, Jong-Fil;Kim, Jae-Chul;Nam, Bong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.264-265
    • /
    • 2006
  • This paper presents direct load control algorithm based locational and electric load characteristics. Direct load control is defined that demand-side management program activities that can interrupt consumer load at the time of annual peak load by direct control of the utility system operator by interruption power supply to individual appliances or equipment on consumer premises. Korean power system is divided into 14-areas considering branches operating in KEPCO, and electric loads are classified into 19 load groups considering interruption costs in this paper. The purpose of proposed method is to decrease social losses by controlling electric loads mainly whose interruption costs are low. It is expected that the proposed algorithm can be used as the countermeasure for the emergency state of the electric power dispatch in a operation point of view.

  • PDF

A design on the control of direct drive robot manipulator using TMS320c30 (TMS320c30을 이용한 직접 구동형 로보트 매뉴퓰레이터의 설계)

  • 손장원;이종수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.520-522
    • /
    • 1996
  • The Direct Drive Arm(DDA) is a SCARA typed direct drive manipulator with two degrees-of-freedom(DOF) using the direct drive motor of the NSK company. A controller system for the SCARA robot of DDA is designed using a DSP (TMS32Oc3O), which has the highest performance among the third DSP chips in the TI company. The design objective of the system is to implement dynamic control algorithms and neural control algorithms for real time learning which require a lot of calculations and large memory and have been tested only by simulations so far. The controller uses a DSP, a high speed D/A, 32-bit Counter and a large DRAM to implement advanced robot control algorithms.

  • PDF