• 제목/요약/키워드: direct system

Search Result 6,850, Processing Time 0.035 seconds

Indications and Estimations of the Needs for Direct Medical Control in the Patients Transported by 119 Rescuers (119 구급대에 의해 이송된 환자들 중 직접적 의료지도가 필요한 범위와 그에 따른 수요 추정)

  • Park, Jae-Young;Jung, Koo-Young;Bae, Hyun-A
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.42-47
    • /
    • 2006
  • Direct medical control by medical doctors is an essential part of emergency medical services system (EMSS). However, the indications are not specifically defined, even in 119 system with their own medical control team. The Seoul Metropolitan Fire and Disaster Management Department has operated internal medical consultation services on its own since January 2004. Based on the experiences from these services, we reviewed the cases of the direct medical consultation and establish the indications for direct medical control. And we presumed the demand of direct medical control with the established indications. The crews of 119 in Seoul made 793 calls to Medical Control Team during November 2004. We reviewed all of the calls according to the level of consciousness (AVPU), the kinds of emergency care done by crews during transport (10 categories), and the mechanisms of injuries (9 categories). The need for direct medical control was judged by authors with reviewing the records reported by the crews and control teams. Among 23 items, 14 items assigned as the indications, which were abnormal level of consciousness (VPU), 6 kinds of emergency care, and 5 mechanisms of injures. The sum of the three of them, 7,782 cases (45.9%), was in need of direct medical control. In conclusion, about half of the patients transported by 119 crews in Seoul require direct medical control. The need for the direct medical control in Seoul was estimated as many as 260 calls per day. To fulfill the need for direct medical control and to provide a effective medical control, the direct medical control should be accomplished through the communications between the crews and the medical staffs in the local hospitals.

Performance Analysis of NVMe SSDs and Design of Direct Access Engine on Virtualized Environment (가상화 환경에서 NVMe SSD 성능 분석 및 직접 접근 엔진 개발)

  • Kim, Sewoog;Choi, Jongmoo
    • KIISE Transactions on Computing Practices
    • /
    • v.24 no.3
    • /
    • pp.129-137
    • /
    • 2018
  • NVMe(Non-Volatile Memory Express) SSD(Solid State Drive) is a high-performance storage that makes use of flash memory as a storage cell, PCIe as an interface and NVMe as a protocol on the interface. It supports multiple I/O queues which makes it feasible to process parallel-I/Os on multi-core environments and to provide higher bandwidth than SATA SSDs. Hence, NVMe SSD is considered as a next generation-storage for data-center and cloud computing system. However, in the virtualization system, the performance of NVMe SSD is not fully utilized due to the bottleneck of the software I/O stack. Especially, when it uses I/O stack of the hypervisor or the host operating system like Xen and KVM, I/O performance degrades seriously due to doubled-I/O stack between host and virtual machine. In this paper, we propose a new I/O engine, called Direct-AIO (Direct-Asynchronous I/O) engine, that can access NVMe SSD directly for I/O performance improvements on QEMU emulator. We develop our proposed I/O engine and analyze I/O performance differences between the existed I/O engine and Direct-AIO engine.

Design and analysis of monitoring system for illegal overseas direct purchase based on C2C (C2C에 기반으로 해외직구 불법거래에 관한 모니터링 시스템 설계 및 분석)

  • Shin, Yong-Hun;Kim, Jeong-Ho
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.609-615
    • /
    • 2022
  • In this paper, we propose a monitoring system for illegal overseas direct purchase based on C2C transaction between individuals. The Customs Act stipulates that direct purchases from overseas are exempted from taxation only if they are less than a certain amount (US$150, but US$200 in the US) or are recognized as self-used goods. The act of reselling overseas direct purchase items purchased with exemption from taxation online, etc., is a crime of smuggling without a report. Nevertheless, the number of re-sells on online second-hand websites is increasing, and it is becoming a controversial social issue of continuous violation of the Customs Act. Therefore, this study collects unspecified transaction details related to overseas direct purchase, refines the data in a big data method, and designs it as a monitoring system through natural language processing, etc. analyzed. It will be possible to use it to crack down on illegal transactions of overseas direct purchase goods.

A Survey of Direct Normal Insolation Resources for the Construction of Solar Thermal Power Generation Sites in Korea (국내 태양열발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2005
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research's new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $5.4kWh/m^2/day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $5.53kWh/m^2/day$ and $5.84kWh/m^2/day$, and for fall and winter their values were $5.3kWh/m^2/day$ and $4.94kWh/m^2/day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

A Survey of Direct Normal Insolation Resources for the Construction of Solar Concentrating Power Generation Sites in Korea (국내 고집광 태양에너지 발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.209-214
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean 2.67 kWh/$m^2$/day of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were 2.91 kWh/$m^2$/day and 2.23 kWh/$m^2$/day, and for fall and winter their values were 2.78 kWh/$m^2$/day and 2.77 kWh/$m^2$/day respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value

  • PDF

Improvement Strategy by Case Study on the Direct Payment Program for Rural Landscape Preservation: Bonghwa-gun, Chungwon-gun, Hongsung-gun (경관보전직불제 시범사업의 시행사례 분석 및 개선방안: 봉화군, 청원군, 홍성군 사례를 중심으로)

  • Jang, Hyo-Sun;Gim, Uhn-Soon;Um, Dae-Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.13 no.4
    • /
    • pp.69-77
    • /
    • 2007
  • The purpose of this study is to analyze the problems of operating the Direct Payment Program for Rural Landscape Preservation and to derive the way of improvement based on case study for three areas in Bonghwa-gun, Cheongwon-gun, Hongseong-gun. The most important factor for the program is farmer's consciousness and positive participation of the farmer who are the subject of this project. Even if farmers are not satisfied with the amount of direct payment income, they try to create income by utilizing landscape preservation crops. Particularly current unit payment dose not surpass the for the crops farm operating costs and payment time is not appropriate for the farming cycle. Hence, it needs to be considered increasing unit payment and rearranging the payment time. Also, we need to introduce incentive system based the degree of fulfillment of the Direct Payment Program in each areas. In general the Direct Payment Program for Rural Landscape Preservation has potentiality to contribute farmer's income stability and the vitalization of region with three revisions.

A Survey of Direct Normal Insolation Resources in Korea (Focused on All days Analysis) (국내 법선면 직달일사량 자원조사 (전일 분석을 중심으로))

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67\;kWh/m^2/day$ of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91\;kWh/m^2/day$ and $2.23\;kWHm^2/day$, and for fall and winter their values were $2.78\;kWh/m^2/day$ and $2.77\;kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

Comparison Study of Long-haul 100-Gb/s DDO-OFDM and CO-OFDM WDM Systems

  • Liu, Ling;Xiao, Shilin;Bi, Meihua;Zhang, Lu
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-562
    • /
    • 2016
  • In this paper, for the first time, the transmission performances of long-haul 100-Gb/s direct detection optical OFDM (DDO-OFDM) and coherent optical OFDM (CO-OFDM) wavelength division multiplexing (WDM) systems are compared by simulation. It provides specific guides for system parameter selection to get a high-performance and cost-effective OFDM WDM system. Specifically, the comparison involves three aspects: launched power is investigated to achieve better system performance; laser linewidth is numerically investigated to choose cost-effective laser; system dispersion tolerances with different laser linewidths are analyzed to further reveal the advantages and disadvantages of these two detecting methods, direct detection and coherent detection, in long-haul OFDM WDM system.

Direct displacement-based seismic design methodology for the hybrid system of BRBFE and self-centering frame

  • Akbar Nikzad;Alireza Kiani;Seyed Alireza Kazerounian
    • Structural Engineering and Mechanics
    • /
    • v.88 no.5
    • /
    • pp.463-480
    • /
    • 2023
  • The buckling-restrained braced frames with eccentric configurations (BRBF-Es) exhibit stable cyclic behavior and possess a high energy absorption capacity. Additionally, they offer architectural advantages for incorporating openings, much like Eccentrically Braced Frames (EBFs). However, studies have indicated that significant residual drifts occur in this system when subjected to earthquakes at the Maximum Considered Earthquake (MCE) hazard level. Consequently, in order to mitigate these residual drifts, it is recommended to employ self-centering systems alongside the BRBF-E system. In our current research, we propose the utilization of the Direct Displacement-Based Seismic Design method to determine the design base shear for a hybrid system that combines BRBF with an eccentric configuration and a self-centering frame. Furthermore, we present a methodology for designing the individual components of this composite system. To assess the effectiveness of this design approach, we designed 3-, 6-, and 9-story buildings equipped with the BRBF-E-SCF system and developed finite element models. These models were subjected to two sets of ground motions representing the Maximum Considered Earthquake (MCE) and Design Basis Earthquake (DBE) seismic hazard levels. The results of our study reveal that although the combined system requires a higher amount of steel material compared to the BRBF-E system, it substantially reduces residual drift. Furthermore, the combined system demonstrates satisfactory performance in terms of story drift and ductility demand.

Study on Economical M&V Methoodology for the Lighting Control System (조명제어시스템 경제적인 실적확인 기법 연구)

  • Choi, Kyung-Shik;Han, Seung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF