• Title/Summary/Keyword: direct solar irradiance

Search Result 25, Processing Time 0.035 seconds

Comparative Analysis on the Characteristic of Typical Meteorological Year Applying Principal Component Analysis (주성분분석에 의한 TMY 특성 비교분석)

  • Kim, Shin Young;Kim, Chang Ki;Kang, Yong Heack;Yun, Chang Yeol;Jang, Gil Soo;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.67-79
    • /
    • 2019
  • The reliable Typical Meteorological Year (TMY) data, sometimes called Test Reference Year (TRY) data, are necessary in the feasibility study of renewable energy installation as well as zero energy building. In Korea, there are available TMY data; TMY from Korea Institute of Energy Research (KIER), TRY from the Korean Solar Energy Society (KSES) and TRY from Passive House Institute Korea (PHIKO). This study aims at examining their characteristics by using Principle Component Analysis (PCA) at six ground observing stations. First step is to investigate the annual averages of meteorological elements from TMY data and their standard deviations. Then, PCA is done to find which principle components are derived from different TMY data. Temperature and solar irradiance are determined as the main principle component of TMY data produced by KIER and KSES at all stations whereas TRY data from PHIKO does not show similar result from those by KIER and KSES.

A Sub-grid Scale Estimation of Solar Irradiance in North Korea (북한지역 상세격자 디지털 일사량 분포도 제작)

  • Choi, Mi-Hee;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • Reliable information on the surface solar radiation is indispensable for rebuilding food production system in the famine plagued North Korea. However, transfer of the related modeling technology of South Korea is not possible simply because raw data such as solar radiation or sunshine duration are not available. The objective of this study is restoring solar radiation data at 27 synoptic stations in North Korea by using satellite remote sensing data. We derived relationships between MODIS radiation estimates and the observed solar radiation at 18 locations in South Korea. The relationships were used to adjust the MODIS based radiation data and to restore solar radiation data at those pixels corresponding to the 27 North Korean synoptic stations. Inverse distance weighted averaging of the restored solar radiation data resulted in gridded surfaces of monthly solar radiation for 4 decadal periods (1983-1990, 1991-2000 and 2001-2010), respectively. For a direct application of these products, we produced solar irradiance estimates for each sub-grid cell with a 30 m spacing based on a sun-slope geometry. These products are expected to assist planning of the North Korean agriculture and, if combined with the already prepared South Korean data, can be used for climate change impact assessment across the whole Peninsula.

Attenuation of the Atmospheric Aerosol Transmissivity due to Air Pollution (대기오염에 의한 대기투과도 감쇠에 대한 연구)

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Lee, Yong-Seob
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.23-29
    • /
    • 1995
  • Relationship between atmospheric aerosol transmissivity and air pollution was analyzed using observed data in a large industrial city, Pusan, Korea. The atmospheric aerosol transmissivity predicted by method of present study in Pusan was assessed by the method of Yamamoto et al.(1968) in order to set up an empirical model to predict the transmissivity using the various meteorological parameters and air pollution. As a result, good correlation between these tow method re observed. Thus, it is possible to conclude that the parameterization of air pollution suggested by this study is another method to give reliable estimate of atmospheric aerosol transmissivity and direct solar irradiance in Pusan.

  • PDF

Spatial Interpolation of Hourly Air Temperature over Sloping Surfaces Based on a Solar Irradiance Correction (일사 수광량 보정에 의한 산악지대 매시기온의 공간내삽)

  • 정유란;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 2002
  • Spatial interpolation has become a common procedure in converting temperature forecasts and observations at irregular points for use in regional scale ecosystem modeling and the model based decision support systems for resource management. Neglection of terrain effects in most spatial interpolations for short term temperatures may cause erroneous results in mountainous regions, where the observation network hardly covers full features of the complicated terrain. A spatial interpolation model for daytime hourly temperature was formulated based on error analysis of unsampled site with respect to the site topography. The model has a solar irradiance correction scheme in addition to the common backbone of the lapse rate - corrected inverse distance weighting. The solar irradiance scheme calculates the direct, diffuse and reflected components of shortwave radiation over any surfaces based on the sun-slope geometry and compares the sum with that over a reference surface. The deviation from the reference radiation is used to calculate the temperature correction term by an empirical conversion formula between the solar energy and the air temperature on any sloped surfaces at an hourly time scale, which can be prepared seasonally for each land cover type. When this model was applied to a 14 km by 22 km mountainous region at a 10 m horizontal resolution, the estimated hourly temperature surfaces showed a better agreement with the observed distribution than those by a conventional method.

Analysis of Solar Irradiance Measurement From a Multi-Filter Radiometer At Kwangju, South Korea.

  • Ogunjobi, K.O.;Kim, Y.J.;He, Z.;Ryu, S.Y.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.335-335
    • /
    • 2001
  • Direct-normal, total horizontal and diffuse horizontal irradiance data obtained from a multi-filter rotating shadowband radiometer over seven different wavelength bands (416nm, 151nm, 616nm, 675nm, 870nm and 940nm and the entire spectrum) has been analyzed at Kwangju, South Korea from June 1998 December 2000. The maximum hourly global radiation flux ranged from 0.44 MJ/$m^2$ to 2.68 MJ/$m^2$ at around 11:00-12:00 Hr local time while the maximum hourly diffuse radiation flux ranged from about 0.96 MJ/$m^2$ to 1.37 MJ/$m^2$. The maximum hourly direct irradiance ranged from 1.42 MJ/$m^2$ to 2.92 MJ/$m^2$ from June1998-2000. During the period under consideration, the average monthly global radiation recorded were 13.09 MJ/$m^2$/day, 10.58MJ/$m^2$/day and 9.78MJ/$m^2$/day for years 1998, 1999 and 2000 respectively, while the diffuse irradiance were 6.54 MJ/$m^2$/day, 5.33 MJ/$m^2$/day and 5.14 MJ/$m^2$/day for f998, 1999 and 2000 respectively. The direct irradiance values at the site were 11.63 MJ/$m^2$/day, 8.24MJ/$m^2$/day and 7.75 MJ/$m^2$/day for 1998, f999 and 2000 respectively. It was observed that each of the years has its own unique meteorological parameters that affect the quality and quantity of radiation received for each month. The annual average daily fractions of the diffuse to the global radiation (KD) were 0.51, 0.61 and 0.59 for years 1998, 1999 and 2000 respectively. Analysis indicated that the average daily KD ranged from 0.13 to a maximum value of 0.99 in May for irradiance measured at the broadband channel while the maximum and minimum KD value of 0.91 and 0.23 was recorded at wavelength band 870nm and 940nm in January and September respectively. The lowest average daily clearness index (Kt) value recorded was 0.03 in May (Spring) and the annual average daily clearness indexes are 0.45, 0.34 and 0.35 for years 1998, f999 and 2000 respectively. The frequency of clear days annually at Kwangju is 67.95%, 29.57% and 40.72% for years 1998, 1999 and 2000 respectively.

  • PDF

A Study on the MPPT Control Method for Grid-connected Multi-String Three-Phase Three-Level PV Inverter (계통연계형 멀티스트링 3상 3레벨 태양광 인버터의 MPPT 제어방법에 관한 연구)

  • Kim, Jinsoo;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2014
  • Two-level inverter has some disadvantages like high harmonics contained in the output current, efficiency limit and stress to switching device as IGBT and FET. Many researches have reported multi-level inverter to complement two-level inverter of problems. In this paper, we suggest MPPT algorithm of multi-string three-level solar inverter that considered nowadays. We added midpoint controller in order to implement the MPPT algorithm because the three-level inverter has to need midpoint controller and procured the stability of direct current link. We verify the superiority of multi-string T-Type inverter and the algorithm we suggested with solar irradiance variation experiment and MPPT efficiency measurement. The MPPT efficiency was confirmed with a high efficiency more than 99.97%.

Direct and Diffuse Radiation Data in Naju During May 2019 to November 2020 (농업적 활용을 위한 산란일사와 직달일사 관측 자료: 나주에서 2019년 5월부터 2020년 11월까지)

  • Kim, Hyunki;Moon, Hyun-Dong;Cho, Yuna;Sin, Seo-Ho;Kim, Jong-Hyeon;Lee, Yang-Won;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.2
    • /
    • pp.134-140
    • /
    • 2021
  • Global solar radiation consists of direct and diffuse radiations. Both components are necessary for not only atmospheric science and solar energy domains but also agricultural applications. In this study, the data of direct and diffuse radiations are uploaded to Github. It was observed in Naju during May 2019 to November 2020. Using this data, the previous empirical equations using the relation between clearness index and diffuse ratio were validated. All coefficients of determination (R2) and RMSE were similar as 0.79~0.80 and 0.13~0.15. However, to get the lower RMSE, other non-linear approaches will be required with more observation data.

Relationship between Exposure Index and Overheating Index in Complex Terrain (복잡지형에서 사면 개방도과 계절별 과열지수 사이의 관계)

  • 정유란;황범석;서형호;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.3
    • /
    • pp.200-207
    • /
    • 2003
  • '||'||'||'&'||'||'||'quot;Overheating index'||'||'||'&'||'||'||'quot;, the normalized difference in incident solar energy between a target surface and a level surface, is helpful in estimating the spatial variation in daily maximum temperature at the landscape scale. It can be computed as the ratio of the 4-hour cumulative solar irradiance surplus or deficit from that over a level surface to the maximum possible deviation (15 MJ $m^{-2}$ ) during the midafternoon. Ecosystem models may, for simplicity, use an empirical proxy (exposure index) variable combining slope and aspect in place of the overheating index to account for the variation of midafternoon solar irradiance. A comparative study with real-world landscape data was carried out to evaluate the performance of exposure index in replacing the overheating index. Overheating indices for summer solstice, fall equinox and winter solstice were calculated at 573,650 grid cells constituting the land surface of Donggye-Myun, Sunchang County in Korea, based on a 10-m DEM. Exposure index was also calculated for the same area and fitted for the variation of overheating index to derive a 2$^{nd}$ -order linear regression equation. The coefficient of determination ($R^2$) was 0.50 on summer solstice, 0.56 on fall equinox, and 0.44 on winter solstice, respectively. These are much lower than the theoretically calculated $R^2$ values ranging from 0.7 in summer to 0.9 in autumn. According to our study, exposure index failed to accurately predict the cumulative solar irradiance over a complex terrain, hindering its application to daily maximum temperature estimation. We suggest direct calculation of the overheating index in preference to using the exposure index.

Development and Evaluation of an Apparatus to Measure the Solar Heat Gain Coefficient of a Fenestration System According to KS L 9107 (KS L 9107에 의한 태양열 취득률(SHGC) 측정장치 개발 및 평가)

  • Kim, Tae-Jung;Choi, Hyun-Jung;Kang, Jae-Sick;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.512-521
    • /
    • 2014
  • Recently, multiple glazing units, frames, complex fenestration systems, and windows with shading devices have been developed to save cooling energy in buildings. However, very little work has been conducted on developing a direct experimental test method of the solar heat gain coefficient(SHGC) for new fenestration techniques. This study aims to develop and evaluate a test apparatus to measure the SHGC, according to the KS L 9107 test method. The performance of the solar simulator was class A, B, and A, for spectral match, non-uniformity, and instability irradiance, respectively. The differences between the measured and calculated SHGC values were found to range between 0.001 and 0.011, and for all test specimens they agreed within 4%. These results establish the validity of the test apparatus. This system is thus expected to be useful in assessing the energy performance for various types of fenestration.

Comparative Studies on Heating and Cooling Loads' of a Building Varied by Annual Weather Data (연도별 기상데이터를 활용한 건물의 냉.난방부하 특성 비교)

  • Lee, Ji-Hoon;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.265-270
    • /
    • 2011
  • The purpose of this study is to compare and analyze the differences of a building's heating and cooling loads depending on the weather variation. Followings are the results. The temperature, humidity and wind speeds of standard year are bigger than those of 2006~2009. The 2006~2009's total horizontal solar irradiance is greater than that of standard year, and the direct solar irradiance of standard year is bigger in winter and vice versa in summer. As results of simulation on heating and cooling loads, it is difficult to find out the bilateral influences between maximum thermal loads and annual's. The equivalent-time operating ratio(EOR) is defined on this study to estimate the differences between year and year, and the EOR of standard year shows low value comparing to 2006~2009 years'.