• Title/Summary/Keyword: dipstick

Search Result 36, Processing Time 0.023 seconds

Diagnostic Value of Dipstick Urinalysis (Leukocyte Esterase and Nitrite) as a Screening Test for Urinary Tract Infection in Acute Febrile Children (급성 발열 환아에서 요로감염 선별검사로서 Dipstick 요분석(Leukocyte esterase와 Nitrite)의 진단적 가치)

  • Hwang Soo-Ja;Park So-Young;Kim Hye-Soon;Park Eun-Ae;Kim Ho-Sung;Seo Jung-Wan;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • Purpose : To evaluate the diagnostic value of dipstick urinalysis($Multistix^{(R)}$) as a screening test for urinary tract infection(UTI) in acute febrile children. Methods : We compared dipstick uinalysis (leukocyte estease(LE) and nitrite) with microscopic urinalysis (WBC and bacteria) and urine culture in 80 children with UTI and 605 children without UTI, who were admitted due to acute fever at EWHA Womans University Hospital between Oct. 1994 and Feb. 1996. Results : 1) In dipstick urinalysis, LE and nitrite were positive in 38.7%, and 13.8% of 80 children with UTI and in 2.1%. and 1.2% of 605 children without UTI. 2) In microscopic urinalysis, WBC and bacteria were positive in 31.2%, and 17.5% of 80 children with UTI and in 4.1%, and 0.6% of 605 children without UTI. 3) Positive rate of LE on dipstick urinalysis was 38.7%, which was significantly higher than 31.5% of WBC on microscopic urinalysis (P<0.05). Positive rate of nitrite was not significantly different to that of bacteria. 4) Sensitivity, specificity, positive predictive value, negative predictive value of dipstick urinalysis were 43.7%, 98.3%, 63.6%, 92.9% which were not significant different to 40.0%, 99.0%, 54.0%, 92.3% of microscopic urinalysis. The sensitivity of combined dipstick and microscopic urinalysis were still low(50%). 5) Additional positive rate of microscopic urinalysis to negative dipstick urinalysis was 6.3%(5/80) in 80 children with UTI. Conclusion : The sensitivity of dipstick urinalysis was low and additional value of microscopic urinalysis was minimal in febrile UTI. So urine culture is mandatory in acute febrile children even though dipstick and microscopic urinalysis are negative.

  • PDF

Urinalysis: The Usefulness and Limitations of Urine Dipstick Testing (요검사: 요시험지봉 검사의 유용성과 한계)

  • Han, Tae Hee
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.42-48
    • /
    • 2013
  • The urinalysis is an essential part of the diagnostic work-up for kidney disease and other renal system disorders. The dipstick test allows rapid and simultaneous chemical analyses of urine, including factors such as pH, specific gravity, protein, glucose, ketones, occult blood, bilirubin, urobilinogen, nitrite, and leukocyte-esterase. The chemical reactions on dipstick are complicated and can be affected by oxidizing, reducing, and discoloring substances in the urine. Therefore, false positive and false negative results are common in dipstick testing. To obtain reliable results with the dipstick, it is necessary to collect urine cleanly and examine the urine carefully. It is mandatory to clearly understand the principles of dipstick testing to evaluate abnormal findings. If the urine dipstick results suggest hematuria, proteinuria, or urinary tract infection, microscopy of the urine should be performed to confirm the findings.

A Dipstick-Type Enzyme-Linked Immunosorbent Assay for the Detection of the Insecticide Fenitrothion in Food Samples

  • Cho, Young-Ae;Shim, Jee-Youn;Lee, Yong-Tae;Lee, Hye-Sung
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.990-992
    • /
    • 2006
  • In a previous study, we obtained polyclonal antibodies against the organophosphorus insecticide fenitrothion and developed an enzyme-linked immunosorbent assay (ELISA) for this pesticide. Using these antibodies and an enzyme tracer, a direct competitive ELISA method specific for fenitrothion using a dipstick format was developed. Dipstick ELISA using antibodies to fenitrothion immobilized on an Immunodyne membrane allowed the quick visual detection of fenitrothion at concentrations above $10\;{\mu}g/L$. The $IC_{50}$ value of dipstick ELISA using reflectance detection was $27\;{\mu}g/L$ with a detection limit of $2\;{\mu}g/L$. The recovery of fenitrothion from spiked lettuce and rice samples using the dipstick ELISA ranged from 87-107%.

Monoclonal Antibody-Based Dipstick Assay: A Reliable Field Applicable Technique for Diagnosis of Schistosoma mansoni Infection Using Human Serum and Urine Samples

  • Demerdash, Zeinab;Mohamed, Salwa;Hendawy, Mohamed;Rabia, Ibrahim;Attia, Mohy;Shaker, Zeinab;Diab, Tarek M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

Colloidal Textile Dye-Based Dipstick Immunoassay for the Detection of Infectious Flacherie of Silkworm, Bombyx mori L.

  • Sivaprasad, V.;Nataraju, B.;Renu, S.;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • Infectious flacherie of silkworm Bombyx mori is caused by B. mori infectious flacherie virus (BmIFV) and causes severe crop loss to sericulturists. In the present study, a colloidal textile dye-based dipstick immunoassay is developed for the detection of infectious flacherie in silkworms. Colloidal textile dye (blue D2R) with Aλ$_{max}$ at 620 nm was sensitised with 500 $\mu\textrm{g}$/ml of purified anti-BmIFV IgG. The dye-antibody reagent detects purified antigen up to 10 ng/ml and BmIFV infection in diseased larval extracts $(up to a dilution of {10^-5})$ and faecal matter extracts $(up to a dilution of {10^-2})$ by forming clear blue dot within 30 min. It was observed to be stable for three months period at $4^{\circ}C$. The efficacy of textile dye-based dipstick immunoassay was on pay with HRP-based dipstick immunoassay and fluorescent antibody test, and better than latex agglutination and ouchterlony tests in the detection of BmIFV The dye-based dipstick immunoassay method provides a simple, sensitive and less expensive test for the detection of BmIFV infection in silkworms.s.

Validity of Expired Carbon Monoxide and Urine Cotinine Using Dipstick Method to Assess Smoking Status (호기 중 일산화탄소와 소변 코티닌 검사의 흡연상태 타당도 분석)

  • Park, Su-San;Lee, Ju-Yul;Cho, Sung-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.4
    • /
    • pp.297-304
    • /
    • 2007
  • Objectives : We investigated the validity of the dipstick method (Mossman Associates Inc. USA) and the expired CO method to distinguish between smokers and non-smokers. We also elucidated the related factors of the two methods. Methods : This study included 244 smokers and 50 ex-smokers, recruited from smoking cessation clinics at 4 local public health centers, who had quit for over 4 weeks. We calculated the sensitivity, specificity and Kappa coefficient of each method for validity. We obtained ROC curve, predictive value and agreement to determine the cutoff of expired air CO method. Finally, we elucidated the related factors and compared their effect powers using the standardized regression coefficient. Results : The dipstick method showed a sensitivity of 92.6%, specificity of 96.0% and Kappa coefficient of 0.79. The best cutoff value to distinguish smokers was 5-6ppm. At 5 ppm, the expired CO method showed a sensitivity of 94.3%, specificity of 82.0% and Kappa coefficient of 0.73. And at 6 ppm, sensitivity, specificity and Kappa coefficient were 88.5%, 86.0% and 0.64, respectively. Therefore, the dipstick method had higher sensitivity and specificity than the expired CO method. The dipstick and expired CO methods were significantly increased with increasing smoking amount. With longer time since the last smoking, expired CO showed a rapid decrease after 4 hours, whereas the dipstick method showed relatively stable levels for more than 4 hours. Conclusions : The dipstick and expired CO methods were both good indicators for assessing smoking status. However, the former showed higher sensitivity and specificity and stable levels over longer hours after smoking, compared to the expired CO method.

Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor (딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

Classification of UTI Using RBF and LVQ Artificial Neural Network in Urine Dipstick Screening Test (RBF와 LVQ 인공신경망을 이용한 요(尿) 딥스틱 선별검사에서의 요로감염 분류)

  • Min, Kyoung-Kee;Kang, Myung-Seo;Shin, Ki-Young;Lee, Sang-Sik;Hun, Joung-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.340-347
    • /
    • 2008
  • Dipstick urinalysis is used as a routine test for a screening test of UTI (urinary tract infection) in primary practice because urine dipstick test is simple. The result of dipstick urinalysis brings medical professionals to make a microscopic examination and urine culture for exact UTI diagnosis, therefore it is emphasized on a role of screening test. The objective of this study was to the classification between UTI patients and normal subjects using hybrid neural network classifier with enhanced clustering performance in urine dipstick screening test. In order to propose a classifier, we made a hybrid neural network which combines with RBF layer, summation & normalization layer and L VQ artificial neural network layer. For the demonstration of proposed hybrid neural network, we compared proposed classifier with various artificial neural networks such as back-propagation, RBFNN and PNN method. As a result, classification performance of proposed classifier was able to classify 95.81% of the normal subjects and 83.87% of the UTI patients, total average 90.72% according to validation dataset. The proposed classifier confirms better performance than other classifiers. Therefore the application of such a proposed classifier expect to utilize telemedicine to classify between UTI patients and normal subjects in the future.

Clinical Significance of the Routine "Dipstick" Urinalyses in Pediatric Inpatients (입원 환아에서의 "dipstick" 소변검사의 임상적 의의)

  • Park, Yong-Hoon;Jun, Jin-Gon
    • Journal of Yeungnam Medical Science
    • /
    • v.1 no.1
    • /
    • pp.115-120
    • /
    • 1984
  • To find clinical significance of routine "dipstick" urinalysis on admission, we analyzed the results of the "dipstick" urinalyses performed in 844 patients admitted to the pediatric department of Yeungnam University hospital from May 1, 1983 to October 31, 1984. Ketonuria, proteinuria, hematuria and glucosuria were found in 9.5%, 4.9%, 2.4% and 1.1% of the patients respectively. There were no significant differences by sex, age and presence of fever. However, proteinuria and ketonuria were found more frequently in the patients with dehydration (p<0.05). The degree of ketonuria showed a positive association w:th the severity of dehydration (p<0.005). All of the patients with proteinuria and ketonuria showed negative results on follow up. However, among 13 patients with hematura, 9 patients showed negative results and 4 patients had persistent hematuria on follow up. These 4 patients were found to have chronic pyelonephritis (2), asymptomatic urinary tract infection (1) and benign recurrent hematuria (1). This routine "dipstick" urinalysis on admission seems to be simple test which is useful in detecting unrecognized kidney and other urinary tract disease.

  • PDF

Dipstick Urine Protein, as a Predictor of Cardiovascular Mortality in Korean Men: Korea Medical Insurance Corporation Study (심혈관 사망 예측인자로써의 반정량적 단백뇨 검사: KMIC 연구)

  • Ha, Kyoung-Soo;Kim, Hyeon-Chang;Kang, Dae-Ryong;Nam, Chung-Mo;Ahn, Song-Vogue;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.5
    • /
    • pp.427-432
    • /
    • 2006
  • Objectives: This study was to investigate if the dipstick proteinuria can predict cardiovascular mortality in a population of Korean men. Methods: We measured urine protein and other cardiovascular risk factors in 100059 Korean men, aged between 35-59 years in 1990 and 1992. Levels of proteinuria measured by dipstick method were trace or less, 1+, 2+, and 3+ or greater. The primary outcomes were deaths from all causes, cardiovascular disease, cancer, and others in a 12 year follow-up from 1993 to 2004. Results: The multivariate-adjusted relative risks (95% CI) for cardiovascular death according to the level of proteinuria (1+, 2+, 3+ and more) in 1990 examination were 2.18 (1.36-3.48), 2.55 (1.37-4.78), and 4.57 (2.16-9.66) respectively. The corresponding relative risks according to the level of proteinuria in 1992 examination were 2.49 (1.71-3.64), 2.64 (1.53-4.58), and 2.78 (1.15-6.73). The relative risks for cardiovascular death of men with proteinuria (1+ or greater) once and twice among the examinations were 2.18 (1.63-2.92) and 3.75 (2.27-6.18), compared with men without proteinuria in 1990 and 1992 examinations. Conclusions: Our results showed that dipstick proteinuria is associated with cardiovascular mortality in Korean men. Dipstick proteinuria could be a predictor for cardiovascular mortality.