• Title/Summary/Keyword: diode laser

Search Result 1,017, Processing Time 0.028 seconds

A study on the fabrication of semiconductor laser for optical sensor (광센서 광원용 반도체 레이저의 제작에 관한 연구)

  • Kim, Jeong-Ho;An, Se-Kyung;Hwang, Sang-Ku;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.2
    • /
    • pp.235-243
    • /
    • 2002
  • Theoretical analysis have been performed to design the high power semiconductor laser for an optical sensor at 1.55${\mu}{\textrm}{m}$ wavelength range which is the lowest loss wavelength in optical fiber. The materials of active region and SCH were $Ln_{1-x}Ga_xAs_yP_{1-y}$. In order to use the light source of optical sensors, it has to satisfy wide spectral width and short coherence length. Therefore, in order to suppress lasing oscillation, we proposed laterally tilted PBH type with a window region. Also, tapered stripe structure was applied for high coupling efficiency into a single mode fiber. From these analyses, the devices of laterally tilted angled and bending structure were fabricated and their characteristics were measured. In the results of the measurement, the fabricated devices have sufficient output power and wide FWHM to apply to the light source of optical fiber sensors.

Fabrication of an Optical Fiber Amplifier Using Long-period Fiber Gratings Formed by Periodically Arrayed Metal Wire (금속선의 주기적 배열로 유도된 장주기 격자를 이용한 이득 평탄화된 광섬유 증폭기 제작)

  • Sohn, Kyung-Rak;Hwang, Woong;Shim, June-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.833-837
    • /
    • 2007
  • In this study, we have fabricated a gain flattened erbium-doped optical fiber amplifier. Gain flattening filters were realized by the strain-induced long period fiber gratings, which are made of periodically arrayed metal wires. Using the filter of $550{\mu}m$ period, spontaneous emission amplified at C-band wavelength by a 980nm pumping laser was flattened within 1dB of gain ripple. The performance of the simultaneous multi channel amplification was measured using a fabry-perot laser diode. Amplification ratio was above 20dB. This amplifier can be applied to the long distance transmission system based on a wavelength division multiplexing for boosting an attenuated signal.

A Study on Temporal Measurement of Size and Concentration for Soot Aggregates among Exhaust Emissions in Diesel Engines (디젤기관 배기 배출물에 있어서 매연 응집체 크기 및 농도의 시간적 계측에 관한 연구)

  • Bae, Myung-Whan;Kamimoto, Takeyuki;Bae, Chang-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.116-124
    • /
    • 2007
  • An optical method to measure the size and number density of soot aggregates in diesel exhaust has been proposed in this study. Two laser beams in co-axial alignment transmit a soot loaded exhaust gas flow, and the transmittance at each wavelength is detected by a photo diode simultaneously. The volume equivalent diameter and number density of soot aggregates in the optical path can be theoretically given by the transmittance values measured at two wavelengths. A test conducted by a single cylinder, 4 cycle, small and DI diesel engine shows that the temporal variations of the size and number density of soot aggregates in the diesel exhaust can be measured by the proposed method at a transient mode operation. It is found that the volume equivalent diameter varied temporally from 70 to 110 nm during the period that high soot concentration is observed. One can also conclude that the optical length longer than 1 m in the dynamic range regarding this method is preferable for measuring soot concentration at the level of $1\;mg/m^3$.

Comparison of Photobiomodulation Therapy Types for Adults with Chronic Pain

  • Choi, Jae-Hee;Lee, Sun-Woong;Kim, Sang-Won;Lee, Keun-Mi;Jung, Seung-Pil
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 2021
  • Purpose : Our study aimed to compare the effectiveness of low-level laser therapy (LLLT) and light-emitting diode therapy (LEDT) for chronic pain intensity reduction and body temperature increase in older adults with chronic pain. Methods : Overall, 144 of 332 participants' records were used in this retrospective chart review. The study was conducted at a private health center in Busan city and the integrative medical center of a tertiary care hospital in Daegu city, South Korea. Patients experiencing chronic pain for over 6 months were assigned to either the LLLT or LEDT group. Both groups underwent 16 sessions of phototherapy held twice a week for 8 weeks, with each session lasting 60 minutes. The primary outcomes for both groups were the mean visual analogue scale (VAS) scores and body temperatures in both groups. The secondary outcome was the correlation between changes in body temperature and pain intensity. Measurements were recorded at the baseline and at each follow-up session. Results : A decrease in pain intensity and an increase in body temperature (p<.001) were observed in both groups. There was a significant difference in the VAS scores and temperature changes between the groups (p<.001). Odditionally, there were significant differences in the patterns of change in the VAS score and body temperature between the groups as the sessions progressed (p<.01), and a strong inverse correlation between body temperature and pain intensity changes were observed (p<.01). Conclusion : The use of photobiomodulation therapy at a specific wavelength may improve pain severity and simultaneously increase the body temperature among elderly people with chronic pain.

Optimization of Optical Coupling Properties of Active-Passive Butt Joint Structure in InP-Based Ridge Waveguide (InP계 리지 도파로 구조에서 활성층-수동층 버트 조인트의 광결합 효율 최적화 연구)

  • Song, Yeon Su;Myeong, Gi-Hwan;Kim, In;Yu, Joon Sang;Ryu, Sang-Wan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.47-54
    • /
    • 2020
  • Integration of active and passive waveguides is an essential component of the photonic integrated circuit and its elements. Butt joint is one of the important technologies to accomplish it with significant advantages. However, it suffers from high optical loss at the butt joint junction and need of accurate process control to align both waveguides. In this study, we used beam propagation method to simulate an integrated device composed of a laser diode and spot size converter (SSC). Two SSCs with different mode properties were combined with laser waveguide and optical coupling efficiency was simulated. The SSC with larger near field mode showed lower coupling efficiency, however its far field pattern was narrower and more symmetric. Tapered passive waveguide was utilized for enhancing the coupling efficiency and tolerance of waveguide offset at the butt joint without degrading the far field pattern. With this technique, high optical coupling efficiency of 89.6% with narrow far field divergence angle of 16°×16° was obtained.

Effects of Low-level Light Therapy at 740 nm on Dry Eye Disease In Vivo

  • Goo, Hyeyoon;Kim, Hoon;Ahn, Jin-Chul;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.50-58
    • /
    • 2019
  • Background and Objectives Low-level light therapy (LLLT) is an application of low-power light for various purposes such as promoting tissue repair, reducing inflammation, causing analgesia, etc. A previous study suggested the effect of light emitting diode (LED) light with the wavelength of 740 nm for promoting wound healing of corneal epithelial cells. This current study aimed to confirm the effect of LLLT for managing inflammation of a dry eye disease (DED) mouse model. Materials and Methods A total of 50C57BL/6 female mice were randomly grouped into 5 groups to compare the effect of LLLT:1) Control group, 2) Only LLLT group, 3) Dry eye group, 4) LLLT in dry eye group, and 5) Early treatment group. DED was induced with 4 daily injections of scopolamine hydrobromide and desiccation stress for 17 days, and LLLT at 740 nm was conducted once every 3 days. To analyze the effect of LLLT on the DED mouse model, tear volume, corneal surface irregularities, and fluorescence in stained cores were measured, and the level of inflammation was assessed with immunohistochemistry. Results The DED mouse model showed significant deterioration in the overall eye condition. After LLLT, the amount of tear volume was increased, and corneal surface irregularities were restored. Also, the number of neutrophils and the level of inflammatory cytokines significantly decreased as well. Conclusion This study showed that LLLT at 740 nm was effective in controlling the corneal conditions and the degree of inflammation in DED. Such findings may suggest therapeutic effects of LLLT at 740 nm on DED.

Analysis of Dynamic Touch-down and Take-off of HAMR Head (열 보조 자기기록 시스템 헤드의 touch-down 과 take-off 해석)

  • Choi, Jong-Hak;Kim, Seok-Hwan;Kim, Ki-Hoon;Park, Young-Pil;Park, No-Cheol;Park, Kyoung-Su
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.61-66
    • /
    • 2012
  • In HDD industry, many technologies have been developed and investigated as means to increase the areal density of drives. Especially, heat assisted magnetic recording (HAMR) system has been considered as the next generation storage device. Most of the HAMR systems use near field optics as heating mechanism. Therefore, light delivery system is indispensable. We considered the light delivery system with laser diode (LD) mount and optical fiber. Mass and stiffness of the HAMR system using these LD mount and optical fiber are changed. The mass and stiffness of the HAMR system affects the slider dynamic behavior. It is necessary to analyze touch down (TD) and take off (TO). And, we performed the TD-TO experiment with HAMR suspension. Finally, we analyzed the result of TD-TO experiments. And we suggested the design of HAMR suspension to improve TD-TO performance.

Fabrication of Pd/poly 3C-SiC Schottky diode hydrogen sensors (다결정 3C-SiC 마이크로 공진기의 온도 특성)

  • Ryu, Kyong-Il;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.130-130
    • /
    • 2009
  • This paper describes the temperature characteristics of polycrystalline 3C-SiC micro resonators. The 1.2 ${\mu}m$ and 0.4 ${\mu}m$ thick polycrystalline 3C-SiC cantilever and doubly clamped beam resonators with 60 ~ 100 ${\mu}m$ lengths were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonance was measured by a laser vibrometer in vacuum at temperature range of $25{\sim}200^{\circ}C$. The TCF(Temperature Coefficient of Frequency) of 60, 80 and 100 ${\mu}m$ long cantilever resonators were -9.79, -7.72 and -8.0 $ppm/^{\circ}C$. On the other hand, TCF of 60, 80 and 100 ${\mu}m$ long doubly clamped beam resonators were -15.74, -12.55 and -8.35 $ppm/^{\circ}C$. Therefore, polycrystalline 3C-SiC resonators are suitable with RF MEMS devices and bio/chemical sensor applications in harsh environments.

  • PDF

양자점 레이저 다이오드의 비대칭 변형 완화층 영향에 관한 연구

  • Kim, Hui-Dong;Kim, Gyeong-Chan;Seo, Yu-Jeong;An, Ho-Myeong;Kim, Dong-Ho;Kim, Tae-Geun;Choe, Won-Jun;Song, Jin-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.175-175
    • /
    • 2009
  • 양자점 (quantum dot) 기반의 반도체 레이저 다이오드(laser diode)는 낮은 문턱전류와 높은 미분 이득 및 높은 특성온도 등과 같은 장점을 갖는다. 이러한 레이저 다이오드의 특성은 양자점 활성층 품질에 의해 큰 영향을 받기 때문에 고품위 양자점 성장에 관한 연구가 활발히 진행되고 있다. 양자점 구조 성장시 발생하는 변형 (strain)은 레이저 다이오드의 문턱전류, 발진 파장, 내부양자효율 등과 같은 특성에 영향을 미치는 중요한 요소이다. 특히, 레이저 다이오드의 고출력 동작을 위해서는 양자점 적층 기술이 중요한데, 이때 양자점 활성층 영역에 많은 변형이 발생한다. 따라서, 양자점 성장후 변형을 감소하기 위한 변형 완화층(strain released layer)에 관한 연구가 활발히 진행되고 있다. 본 논문에서는 변형 완화층 연구의 일환으로 비대칭 변형 완화층의 조성 및 두께 변화에 따른 양자점 파장 변화에 대한 연구를 수행하였다.

  • PDF

3-axis Moving Magnet Type Actuator (가동 자석형 3 축 구동 엑츄에이터)

  • Hur, Young-Jun;Song, Myeong-Gyu;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1033-1036
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to equip 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added tilting mechanism to 2-axis moving magnet actuator which is designed in previous research. Addition of the tilting mechanism cuts down the focusing sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF