• Title/Summary/Keyword: diode laser

Search Result 1,017, Processing Time 0.028 seconds

Laser Doppler blood flowmeter using self-mixing effect for the measurement of tissue blood flow. (조직혈류측정을 위한 자기혼합형 레이저 도플러 혈류계의 검토.)

  • Ko, Han-Woo;Choi, Duck-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.67-70
    • /
    • 1993
  • This preliminary study describes the self-mixing effect of laser diode for the measurement of tissue blood flow. A self-mixing effect of laser diode was detected by the single-mode laser diode and the moving target, and the Doppler shifted frequency was thanked linearly with the driving frequency of speaker. The measured Doppler shifted frequency was compared with the simulated data.

  • PDF

Research about ESPI System Algorithm Development that Use Modulating Laser (Modulating Laser를 이용한 ESPI System algorithm 개발에 관한 연구)

  • Kim, Seong-Jong;Kang, Young-June;Park, Nak-Kyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.65-72
    • /
    • 2009
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and its ability to measure a broad area in real-time all at once. In conventional laser interferometry, for example out-of-plane ESPI (Electronic Speckle Pattern Interferometry), in plane ESPI, shearography and holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of laser interferometry using a laser diode is proposed. Using Laser Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the laser diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD (Laser Diode) Modulating interferometry that involves four-frame phase shift method. This study proposes a four-frame phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Using modulating laser and research of measurement algorithm does comparison with existent ESPI measurement algorithm. Algorithm measures using GPIB communication through most LabVIEW 8.2. GPIB communication does alteration through PC. Transformation of measurement object measures through modulating laser algorithm that develops. Comparison of algorithm of modulating laser developed newly with existent PZT algorithm compares transformation price through 3-D. Comparison of 4-frame phase mapping, unwrapping, 3-D is then introduced.

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

Anticancer Effect of Photodynamic Therapy using 9-Hydroxypheophorbide-$\alpha$ and 660nm Diode Laser on Human Squamous Cell Carcinoma Cell Line (인체 편평상피세포암세포주에서 9-Hydroxypheophorbide-$\alpha$와 660nm Diode 레이저를 이용한 광역학치료의 항암효과)

  • Kim Han-Gyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.3-7
    • /
    • 2001
  • Objectives: New photosensitizer 9-hydroxypheophorbide-$\alpha$(9-HpbD-$\alpha$) was derived from chlorophyll in water with peak absorption at 660nm. 9-HpbD-$\alpha$ was tested with 660 nm diode laser for the anticancer effect of photodynamic therapy. Materials and Methods: Human SNU 1041 cells were seeded into 96 well plate at a density of $$ cells/well for 24 hours. Cells were washed with media containing various concentration of 9-HpbD-$\alpha$ ranging from $0{\mu}g/ml\;to\;3.75{\mu}g/ml$. Then, laser treatment was done with 660nm diode laser ($10mW/cm^2$) at various time setting (0, 30, 60, 90, 120 minutes) and with various time interval (0, 1, 4, 6, 18 hours). The treated cells were incubated 48 hours and MTT assay was done to measure the viability of cells. Results: The viability of cells was more than 90% after laser treatment in control group. The viability of cells was decreased with increasing concentration of 9-HpbD-$\alpha$ and laser treatment time in experimental groups. The viability of cells was decreased significantly as the interval time between addition of 9-HpbD-$\alpha$ and laser irradiation was increased. Conclusion: This study shows the anticancer effect of photodynamic therapy using 9-HpbD-$\alpha$ and 660nm Diode laser on carcinoma cell line. 9-HpbD-$\alpha$ is considerd as one of new photo sensitizers in the field of photodynamic therapy.

  • PDF

Design of General Audio Optical Pick-up Using Hologram Laser Diode (홀로그램 레이저 다이오드를 이용한 일반 오디오용 광학픽업 설계)

  • 최영석
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.1-8
    • /
    • 1998
  • In this paper, the optical pick-up used for general audio/video players having more market share than the others is designed with 4-wire suspension type actuator and the hologram laser diode which laser diode, photo diode, beam splitter, and grating lens are integrated in. This optical pick-up is designed in very simple optical system with the characteristics of hologram laser diode. Thus, it has high productivity, the number of the parts is reduced, and also the shape of the assembling parts becomes simple.

  • PDF

Optimization of a Passively Q-switched Yb:YAG Laser Ignitor Pumped by a Laser Diode with Low Power and Long Pulse Width

  • Kim, Jisoo;Moon, Soomin;Park, Youngin;Kim, Hyun Su
    • Current Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.127-133
    • /
    • 2020
  • We successfully constructed a passively Q-switched Yb:YAG laser ignitor pumped by a diode laser with low power and long pulse width. To the best of our knowledge, this is the first study to achieve a quasi-MW output power from an optimized Q-switch Yb:YAG laser ignitor by using a pumping diode laser module emitting at under a power of 23 W. The output pulse energy of our optimized laser is 0.98 mJ enclosed in a 1.06 ns pulse width, corresponding to a peak power of 0.92 MW.

Study on robot end-effector tracking using structured laser pattern diode (구조화 레이저패턴다이오드를 이용한 Robot End-Effector 추적연구)

  • 조재완;이남호;이용범;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.523-526
    • /
    • 1996
  • In this paper, robot endeffector tracking using sensory information from structured laser pattern diode, is described. In order to track robot endeffector robustly irrespective of translation, scaling and rotation of robot working tool, structured laser pattern is used as track feature. Structured laser patterns of crosshair, concentric circles, dot matrix, and parallel lines are illuminated to robot endeffector. Illuminated laser patterns are held invariently and coherently irrespective of various motions of robot endeffector. Extracting and tracking these invariant structured laser patterns as track feature, the whole system keeps tracking of the robot endeffector robustly and effectively provided that structured laser pattern is always assumed to aim at robot endeffector.

  • PDF

Optimization of Diode-pumped Cesium Vapor Laser Using Frequency Locked Pump Laser

  • Hong, Seongjin;Kong, Byungjoo;Lee, Yong Soo;Oh, Kyunghwan
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.443-447
    • /
    • 2018
  • We propose a diode-pumped cesium laser using frequency locking of a pump laser that can effectively increase the maximum output power of the cesium laser. We simultaneously monitored the absorption spectrum of cesium and the laser output power, and the frequency of pump laser was locked at the center of the $D_2$ absorption line of the cesium atom to obtain an effective gain enhancement. Using this scheme, we have achieved output power increase of ~0.1 W compared to when frequency locking was not applied. Furthermore, by optimizing the temperature of the cesium cell and the reflectivity of the output coupler, we successfully achieved an output power of 1.4 W using the pump power of 2.9 W, providing a slope efficiency of 61.5% and optical-to-optical efficiency of 49%.

The effect of infrared rays diode irradiation on collagen formation (적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement

  • Tuncdemir, Ali Riza;Yildirim, Cihan;Ozcan, Erhan;Polat, Serdar
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.457-463
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P> .05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.