• Title/Summary/Keyword: dimensionless

Search Result 1,069, Processing Time 0.025 seconds

Effect of Vibration on Natural Convective Heat Transfer around a Spherical Body (구형물체 주위의 자연대류 열전달에 대한 진동효과)

  • Pak Hi-Yong;Cho Seung-Hwan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.3
    • /
    • pp.151-159
    • /
    • 1978
  • A heat transfer model for the case of simultaneous vibration of both the heated surface and its surrounding medium is constructed and the dimensional analysis is applied to this model in order to and the governing dimensionless Parameters in which the vibration effects the heat transfer. In the second Part of this study, an experimental investigation of the effect of vibration on natural convective heal transfer from spheres has been performed for the case of the external oscillatory motion being imposed on the heated surface which is immersed in an otherwise undisturbed air, The ranges of the experimental variables were: temperature difference 10 to $120^{\circ}C$; vibration frequency 10 to 120Hz; displacement amplitude 1.3 to 12.5mm. Three different diameter aluminum were used as the experimental models. Improvements in heat transfer due to vibration were observed, with the maximum increase being 330 Percent. A dimensionless correlation describing the measured heat transfer data is given.

  • PDF

PRELIMINARY PROJECT OF WATER SUPPLY FOR NDATA FARM, MALAWA

  • Min-Shun Lee;Hung-Kwai Chen;Sheng Liang;Ho-Shong Hou
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1615-1617
    • /
    • 2009
  • The water resources project of 320 Ha second stage reclamation, in which including an University City, out of 800 Ha Ndata Farm, Malawa, had been under studied in this research. The challenge of C value of runoff coefficient was obtained as 0.8, by introducing the attenuation factors method, proposed by second author, an IDF dimensionless method customary used in Taiwan, proposed by the third author, is translated further to solve the project design rainfall; Rational Method, thus, obtains 11.5 CMS as the 5 year recurrence storage. The final job, completed by the third author's on-site performance, includs field alignments and discussions with the trustee, Malawa President H. E. Dr. Bingu Wa Mutharika, when a special concern of anti-theft. In order to provide sufficient supply up to an amount of 44,000 M3 during April to November, the sketch package includes 6 measurements: one water barrage, one sluice gate, one intake, one sediment reservoir, one water reservoir, and 3199 Km long gravity-driving hydraulic pipe.

  • PDF

Thermal post-buckling and primary resonance of porous functionally graded beams: Effect of elastic foundations and geometric imperfection

  • Jia-Qin Xu;Gui-Lin She
    • Computers and Concrete
    • /
    • v.32 no.6
    • /
    • pp.543-551
    • /
    • 2023
  • In this article, thermal post-buckling and primary resonance of the porous functionally graded material (FGM) beams in thermal environment considering the geometric imperfection are studied, the material properties of FGM beams are assumed to vary along the thickness of the beam, meanwhile, the porosity volume fraction, geometric imperfection, temperature, and the elastic foundation are considered, using the Euler-Lagrange equation, the nonlinear vibration equations are derived, after the dimensionless processing, the dimensionless equations of motion can be obtained. Then, the two-step perturbation method is applied to solve the vibration problems, the resonance and thermal post-buckling response relations are obtained. Finally, the functionally graded index, the porosity volume fraction, temperature, geometric imperfection, and the elastic foundation on the resonance behaviors of the FGM beams are presented. It can be found that these parameters can influence the thermal post-buckling and primary resonance problems.

Numerical Analysis of the Non-Isothermal Heat Transfer in Solids Conveying Zone of a Single Screw Extruder (단축압출기 고체수송부에서의 비등온 열전달 현상에 관한 수치 해석)

  • Ahn Young-Cheol
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.549-556
    • /
    • 2005
  • Effects of the dimensionless variables on the heat transport phenomena in the extrusion process of a single screw extruder have been studied numerically. Based on the understanding of the solids conveying related to the geometrical structure and characteristics of the screw, the heat balance equation for the solids conveying zone was established and normalized. The finite volume method and power-law scheme were applied to derive a discretized equation and the equation was solved using the alternating direction iterative method with relaxation. Effects of the dimensionless parameters, Biot and Peclet numbers, that define the heat transfer characteristics of the solids conveying zone have been investigated with respect to the temperature of the feeding zone and the length of the solids conveying zone. As the Biot number is increased, the heat loss by cooling dominates to decrease the temperature of the barrel but it has little effects on the temperature of the solids bed and the length of the solids conveying zone. On the other hand, if the Peclet number is increased, the convection term dominates to decrease the temperature of the solids bed and it results in an increase in the length of the solids conveying zone.

Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires (구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석)

  • You, Woo Jun;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • In this study, the relations of the wall thermal conductivity and surface temperature in a compartment fire are investigated using Buckingham Pi theorem. The dimensionless parameters of the previous study are analyzed in order to correlate the dimensionless groups of the heat release rate, the thermal conductivity, the volume of compartment and the convective heat transfer coefficient. In addition the reduced scale of compartment, which has 1/6 size of ISO 9705 Room Corner Tester, is manufactured and the oxygen concentration and the maximum temperature in the space are measured for the gasoline pool fire ($10cm{\times}10cm$, $15cm{\times}15cm$ and $20cm{\times}20cm$). Finally, the criterion of the wall temperature increase are suggested in accordance with the thermal conductivity and the convective heat transfer coefficient. In addition, the dimensionless empirical equation using Buckingham Pi theorem considering the heat release rate are presented suggested. The results of this study will be useful especially for the fire phenomenon investigation of the wall thermal conductivity coefficient and shape in the compartment space.

A Study on the Heat Transfer Characteristics in the Composite Heat Pipe as Modeling Turbine Rotor (터어빈 회전차를 모델로하는 복합 히이트파이프의 전열특성에 대한 연구)

  • Kwon, Sun-Sok;Jang, Yeong-Suc;Yoo, Byung-Wook
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.120-132
    • /
    • 1993
  • The purpose of this research is to study the characteristics of heat transfer in composite rotary heat pipe as modeled turbine rotating by a finite element analysis and experiment. Nu number, Re number, Pr number and dimensionless condensate layer thickness by thermal input and revolutions per minute were given as analysis factors. The comparison between calculated and experimental data showed similar tendency. Therefore the analysis method may be useful to predict the performance of composite heat pipe. The resistance on heat pipe showed the best effect of heat transfer by film condensation, by decreasing film condensation, the heat transfer rate from condenser was increased rapidly. The dimensionless condensate layer thickness according to Re number at given Pr number showed constant values, the dimensionless condensate layer thickness is proportionate to the square root of inverse of revolution number per minute. In this study Nu=A$({\delta}({\omega}/v)^{-1/2}Re^B)$ is used to the convection heat transfer coefficient and A=0.963, B=0.5025 were obtained as analysis predicts.

  • PDF

Hydraulic Characteristics of Train Carriage Artificial Reef in Wave and Current Field Conditions (파랑.흐름 공존장에서의 철도차량 인공어초의 수리학적 특성)

  • Sohn, Byung-Kyu;Yi, Byung-Ho;Yoon, Han-Sam
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.108-117
    • /
    • 2011
  • Old train carriages have been used to create artificial reefs (AR) as part of programs to enhance ocean fisheries and recreational resources. This study conducted hydraulic modeling experiments to estimate the structural stability of a train carriage AR. By applying fixed- and movable-bed conditions and Froude similitude, theoretical and hydraulic experiments revealed major design forces(e.g., water waves and currents). The results of this study showed that some dimensionless design parameters (e.g., surf similarity parameters, water particle velocity, scouring, and deposition) also affect the stability of an AR under various wave and current field conditions. In the fixed-bed condition, movement of the AR occurred when dimensionless water particle velocity based on the surf similarity parameter was larger than about 0.32. In the moveable-bed condition, the settlement depth (field values) of the AR ranged from 6 to 30 cm. The results indicated that characteristics of the sediment/bed condition and the direction of external forces acting on an AR should be considered when selecting AR sites.

An Experimental Study for Local Scour of the Riverbed at Pier (교각주변(橋脚周邊) 하상(河床)의 국부세굴(局部洗掘)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Won Hwan;Lee, Jung Sik;Lee, Hong Rae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.65-74
    • /
    • 1985
  • This study is an experimental analysis for local scour of the riverbed at pier. The basic equation with dimensionless elements(Pier Reynolds Number, Dimensionless Turbulence Intensity) is derived through dimensional analysis. After testing the goodness of fit of data, the coefficients are determined by multiple regression analysis. In the region where the value of the attack angle is near 20 degrees, there exists a transition region where the slope of equation with Pier Reynolds Number changes from positive to negative and that of equation with Dimensionless Turbulence Intensity changes from negative to positive adversely. As a result of testing the equation suggested on this study by using the data of the Institute of National Construction, it is found that the scour depth and width at pier can be predicted approximately.

  • PDF

The Effect of Nozzle Height on Heat Transfer of a Hot Steel Plate Cooled by an Impinging Water Jet (충돌수분류에 냉각되는 고온 강판의 열전달에 있어 노즐높이의 영향에 대한 연구)

  • Lee, Pil-Jong;Choi, Hae-Won;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.668-676
    • /
    • 2003
  • The effect of nozzle height on heat transfer of a hot steel plate cooled by an impinging liquid jet is not well understood. Previous studies have been based on the dimensionless parameter z/d. To test the validity of this dimensionless parameter and to investigate gravitational effects on the jet, stagnation velocity of an impinging liquid jet were measured and the cooling experiments of a hot steel plate were conducted for z/d from 6.7 to 75, and an inverse heat conduction method is applied for the quantitative comparison. Also, the critical instability point of a liquid jet was examined over a range of flow rates. The experimental velocity data for the liquid jet were well correlated with the dimensionless number 1/F $r_{z}$$^2$based on distance. It was thought that the z/d parameter was not valid for heat transfer to an impinging liquid jet under gravitational forces. In the cooling experiments, heat transfer was independent of z when 1/F $r_{z}$$^2$< 0.187(z/d = 6.7). However, it was found that the heat transfer quantity for 1/F $r_{z}$$^2$=0.523(z/d = 70) is larger 11% than that in the region for 1/F $r_{z}$$^2$=0.187. The discrepancy between these results and previous research is likely due to the instability of liquid jet.uid jet.

Analysis of Dredging Efficiency for Operation of Dredging Cutter Head (준설용 커터헤드 운영방식에 따른 준설효율 향상특성 분석)

  • Chae, Dongseok;Park, Jae-Hyeon;Kim, Young Do;Kim, Myunghak;Lee, Mansoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.5
    • /
    • pp.5-9
    • /
    • 2009
  • In this experiment, the cutter head was designed as the down-scaled shape from the cutter head of the Asan-3 of Hyundai Construction Company. The dredging simulation instrument was installed in the experiment water tank which has the dimension of $4.2m(L){\times}2.2m(W){\times}1.5m(H)$. The speed of all components were controlled manually through the hydraulic tool and motors to find the effective desilting condition. As the results, the experiment was conducted to find the optimate dredging cutter head operation rate. To compare the factors which effect on the dredging effectiveness, the dimensionless dredging volume ratio was introduced and it can be found the best effectiveness at 2.0 m/s suction speed, 8 cm dredging depth and 4~4.5 dimensionless dredging volume ratio. Therefore, in order to take the best effectiveness these 3 components factors should be adequately considered.

  • PDF