• Title/Summary/Keyword: dilution method

Search Result 814, Processing Time 0.027 seconds

Errors in Isotope Dilution Caused by Matrix-induced Mass Bias Effect in Quadrupole Inductively Coupled Plasma-Mass Spectrometry

  • Pak, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3482-3488
    • /
    • 2014
  • Matrix-induced mass bias and its effect on the accuracy of isotope ratio measurements have been examined for a quadrupole-based inductively coupled plasma-mass spectrometer (Q ICP-MS). Matrix-induced mass bias effect was directly proportional to % mass difference, and its magnitude varied for element and nebulizer flow rate. For a given element and conditions in a day, the effect was consistent. The isotope ratio of Cd106/Cd114 under $200{\mu}g\;g^{-1}$ U matrix deviated from the natural value significantly by 3.5%. When Cd 111 and Cd114 were used for the quantification of Cd with isotope dilution (ID) method, the average of differences between the calculated and measured concentrations was -0.034% for samples without matrix ($0.076{\mu}g\;g^{-1}$ to $0.21{\mu}g\;g^{-1}$ for the period of 6 months). However, the error was as large as 1.5% for samples with $200{\mu}g\;g^{-1}$ U. The error in ID caused by matrix could be larger when larger mass difference isotopes are used.

Nano-particles of Mechanochemical Synthesis

  • Urakaev, Farit Kh.
    • Journal of the Speleological Society of Korea
    • /
    • no.71
    • /
    • pp.5-11
    • /
    • 2006
  • A theoretical investigation of the solid phase mechanochemical synthesis of nano sized target product on the basis of dilution of the initial powdered reagent mixture by another product of an exchange reaction is presented. On the basis of the proposed 3 mode particle size distribution in mechanically activated mixture, optimal molar ratios of the components in mixture are calculated, providing the occurrence of impact friction contacts of reagent particles and excluding aggregation of the nanosized particles of the target reaction product. Derivation of kinetic equations for mechanochemical synthesis of nanoscale particles by the final product dilution method in the systems of exchange reactions is submitted. On the basis of obtained equations the necessary times of mechanical activation for complete course of mechanochemical reactions are designed. Kinetics of solid phase mechanosynthesis of nano TlCl by dilution of initial (2NaCl+$Tl_2SO_4$) mixture with the exchange reaction product (diluent,$zNa_2SO_4$, z=z*=11.25) was studied experimentally. Some peculiar features of the reaction mechanism were found. Parameters of the kinetic curve of nano TlCl obtained experimentally were compared with those for the model reaction KBr+TlCl+zKCl=(z+1) KCl+TlBr (z=z1*=13.5), and for the first time the value of mass transfer coefficient in a mechanochemical reactor with mobile milling balls was evaluated. Dynamics of the size change was followed for nanoparticle reaction product as a function of mechanical activation time.

Effect of the Welding Methods on the Characteristics of Overlaying Seat-surfaces of Engine Valves (엔진밸브 시트 표면의 오버레이층 특성에 미치는 용접법의 영향)

  • 이병영;최병길
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.517-524
    • /
    • 2002
  • An overlaying of the seating surfaces of engine valves by OAW, GTAW or PTA weldings are common practice. The OAW method of a lower torch energy density compared to GTAW and PTA methods produces smoother deposits but the pain size at the vicinity of the interface is increased remarkably up to $30~50{\mu\textrm{m}}$ (that of base metal is about $10\mu\textrm{m}$). It's grain coarsening and the solute dilution are related to the decarburizing during OAW could be minimized by reducing the preheating temperature and by maintaining the carbide precipitates in base metal prior to welding. The formation of columnar structures and carbide precipitation zone in the vicinity of the GTAW welded interface, because of the high heat concentration, causes weakened zone on the valve seat face. The width of the reaction boundary zone is about $50\mu\textrm{m}$ for PTA and GTAW overlaying, and about $150\mu\textrm{m}$ for OAW welding. The smaller width of the reaction boundary zone is the less the solute-dilution rate. Thereby PTA welding may be recommended for overlaying of the seating surfaces.

Theory of Nanoparticles Mechanosynthesis

  • Urakaev, Farit Kh.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.405-406
    • /
    • 2005
  • A theoretical investigation of the solid-phase mechanochemical synthesis of nano-sized target product on the basis of dilution of the initial powdered reagent mixture by another product of an exchange reaction is presented. On the basis of the proposed 3-mode particle size distribution in mechanically activated mixture, optimal molar ratios of the components in mixture are calculated, providing the occurrence of impact-friction contacts of reagent particles and excluding aggregation of the nanosized particles of the target reaction product. Derivation of kinetic equations for mechanochemical synthesis of nanoscale particles by the final product dilution method in the systems of exchange reactions is submitted. On the basis of obtained equations the necessary times of mechanical activation for complete course of mechanochemical reactions are designed. Kinetics of solid phase mechanosynthesis of nano-TlCl by dilution of initial (2NaCl + $Tl_2SO_4$) mixture with the exchange reaction product (diluent, $zNa_2SO_4$, $z=z^*=11.25$) was studied experimentally. Some peculiar features of the reaction mechanism were found. Parameters of the kinetic curve of nano-TlCl obtained experimentally were compared with those for the model reaction KBr + TlCl + zKCl = (z + 1) KCl + TlBr ($z=z_l^*=13.5$), and for the first time the value of mass transfer coefficient in a mechanochemical reactor with mobile milling balls was evaluated. Dynamics of the size change was followed for nanoparticle reaction product as a function of mechanical activation time.

  • PDF

Detection of IgG and IsM Antibodies with Immunofluoreseent Antibody Technique in Buman Trichomoniasis (질트리코모나스증에서 간접형광항체법을 이용한 혈청내 항질트리코모나스 IgG 및 IgM 항체의 측정)

  • 윤경찬;김경민;안명희;민득영;차동수
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.1
    • /
    • pp.7-12
    • /
    • 1987
  • The indirect fluorescent antibody(IFA) test was used to detect serum IgG and IgM antibodies to Trichomonas vaginalis in 31 vaginal trichomoniasis, 7 candidiasis and in 20 non-infected healthy women with antigen prepared from axonic culture of Trichomenas vaginalis isolated from vulvovaginitis patient. The results were as follows: 1. In 31 vaginal trichomoniasis the positive reactions of IgG antibody were 27 in the 1/8 dilution or higher and :l in the 1/4 dilution whereas in healthy women the reaction showed significantly low as in the 1/4 dilution or below. 2. The sensitivity and specificity of IFA test for IgG antibody to trichomonad antigen in this study were 87.1% and 100%, respectively. 3. No significant difference of IgM antibody levels between vaginal trichomoniasis and healthy women was observed. 4. No relation between the levels of IgG and IsM antibodies to trichomonad antigen by IFA test was observed. 5. No relation between the time lapse and the level of serum IgG antibodies in IFA test of vaginal trichomoniasis was regarded. In conclusion the present study suggests that IFA test in trichomoniasis could be a useful tool for detection of anti-trichomonad IgG antibodies and applicable as an immunodiagnostic method.

  • PDF

Si wafer passivation with amorphous Si:H evaluated by QSSPC method (비정질 실리콘 증착에 의한 실리콘 웨이퍼 패시베이션)

  • Kim, Sang-Kyun;Lee, Jeong-Chul;Dutta, Viresh;Park, S.J.;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.214-217
    • /
    • 2006
  • p-type 비정질 실리콘 에미터와 n-type 실리콘 기판의 계면에 intrinsic 비정질 실리콘을 증착함으로써 계면의 재결합을 억제하여 20%가 넘는 효율을 보이는 이종접합 태양전지가 Sanyo에 의해 처음 제시된 후 intrinsic layer에 대한 연구가 많이 진행되어 왔다. 하지만 p-type wafer의 경우는 n-type에 비해 intrinsic buffer의 효과가 미미하거나 오히려 특성을 저하시킨다는 보고가 있으며 그 이유로는 minority carrier에 대한 barrier가 상대적으로 낮다는 것과 partial epitaxy가 발생하기 때문으로 알려져 있다. 본 연구에서는 partial epitaxy를 억제하기 위한 방법으로 증착 온도를 낮추고 QSSPC를 사용하여 minority carrier lifetime을 측정함으로써 각 온도에 따른 passivation 특성을 평가하였다. 또한 SiH4에 H2를 섞어서 증착하였을 경우 각 dilution ratio(H2 flow/SiH4 flow)에서의 passivation 특성 또한 평가하였다. 기판 온도 $100^{\circ}C$에서 증착된 샘플의 lifetime이 가장 길었으며 그 이하와 이상에서는 lifetime이 감소하는 경향을 보였다 낮은 온도에서는 박막 자체의 결함이 증가하였기 때문이며 높은 온도에서는 partial epitaxy의 영향으로 추정된다. H2 dilution을 하여 증착한 샘플의 경우 SiH4만 가지고 증착한 샘플보다 훨씬 높은 lifetime을 가졌다 이 또한 박막 FT-IR결과로부터 H2 dilution을 한 경우 compact한 박막이 형성되는 것을 확인할 수 있었는데 radical mobility 증가에 의한 박막 특성 향상이 원인으로 생각된다.

  • PDF

A Study on Characteristics of Concrete Impregnated with the Inorganic Surface Penetration Agents (무기계 표면침투제 용액으로 함침한 콘크리트의 특성 연구)

  • Bae, Ju-Seong;Kim, Hyeok-Jung;Park, Gook-Jun;Han, Jong-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • The concrete structure's durability and integrity is reduced owing to various deterioration phenomena. Therefore, it is important to prevent the deterioration phenomena. This study inquired into the various experimental results of specimens with different dilution concentration and impregnation time by the each solution to present the economic and efficient using method of the inorganic surface penetration agents. As a results, the reasonable dilution concentration and impregnation time of colloidal silica solutions are 15% and 5 minute and for the sodium alumina silicate solutions are 17% and 10 second.

Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent (조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가)

  • Choi, Kwan-Woo;Seo, Sung-Mi;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5124-5130
    • /
    • 2014
  • Dilution of the contrast agent by analyzing the change in the signal intensity during MR angiography in accordance with the viscosity and osmotic pressure minimizes the side effects, and improves the image quality. The contrast agent molarity changes by the dilution of the contrast agent in the blood, as it is injected, which leads to a change in signal intensity. Based on this principle, a phantom was prepared and experiments were performed. After the phantom experiment, a clinical experiment was conducted using the results of the phantom experiment. From November 2013 to January 2014, a group of patients were classified into diluted contrast agent (30 persons) and undiluted (30 persons), and the signal intensity of the cerebral vessels was compared. The signal intensity of the phantom according to the molarity of the contrast agent increased sharply from 0.0125 mmol, reached a peak at 20 mmol, and achieved equilibrium from 200 mmol. Based on the study results, the signal intensity of the blood vessels in the brain through were compared in a clinical experiment. All the brain vessels in the imaging range with diluting a high content of the gadolinium contrast agent showed high signal intensity. This result supports the phantom experiment and means that using the 500mmol diluted contrast agent is better than using 1000mmol undiluted contrast agent because it is easier to approach the 20mmol level needed to achieve the highest signal intensity. This study has significance in that it can minimize the high viscosity and osmotic pressure, which can cause side effects and improve the image quality using the method of the dilution rate.

Dilution of Precision (DOP) Based Landmark Exclusion Method for Evaluating Integrity Risk of LiDAR-based Navigation Systems

  • Choi, Pil Hun;Lee, Jinsil;Lee, Jiyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.3
    • /
    • pp.285-292
    • /
    • 2020
  • This paper introduces a new computational efficient Dilution of Precision (DOP)-based landmark exclusion method while ensuring the safety of the LiDAR-based navigation system that uses an innovation-based Nearest-Neighbor (NN) Data Association (DA) process. The NN DA process finds a correct landmark association hypothesis among all potential landmark permutations using Kalman filter innovation vectors. This makes the computational load increases exponentially as the number of landmarks increases. In this paper, we thus exclude landmarks by introducing DOP that quantifies the geometric distribution of landmarks as a way to minimize the loss of integrity performance that can occur by reducing landmarks. The number of landmarks to be excluded is set as the maximum number that can satisfy the integrity risk requirement. For the verification of the method, we developed a simulator that can analyze integrity risk according to the landmark number and its geometric distribution. Based on the simulation, we analyzed the relationship between DOP and integrity risk of the DA process by excluding each landmark. The results showed a tendency to minimize the loss of integrity performance when excluding landmarks with poor DOP. The developed method opens the possibility of assuring the safety risk of the Lidar-based navigation system in real-time applications by reducing a substantial amount of computational load.

Thermal Ion Mass Spectrometry with Isotope Dilution Method: An application to Rare Earth Element Geochemistry (동위원소희석법을 이용한 열이온 질량분석: 희토류원소 지구화학에의 응용)

  • ;;;增田彰正
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.190-201
    • /
    • 2001
  • Isotope Dilution Mass Spectrometry(IDMS) is one of the analytical method which uses enriched isotope spikes and analyzes the abundance of element by comparison of the spectrum between spiked mass and non-spike mass. Especially, the Thermal Ion Mass Spectrometry with isotope dilution technique (in general ID-TIMS) is the most accurate method of the chemical analysis, which enables us to obtain the data better than 1% in accuracy and precision. In IDMS, enriched isotope spike is one of the most important factor in order to obtain the best data. For rare earth elements, in general, a mixture of /sup 138/La, /sup 142/Ce, /sup 145/Nd, /sup 149/Sm, /sup 151/Sm, /sup 151/Eu, /sup 157/Gd, /sup 163/Dy, /sup 167/Er, /sup 171/Yb, and /sup 176/Lu is used as composite spike. IDMS is very useful in geochronology and REE geochemistry. Especially, it is very effective in studying the “tetrad effect” of rare earth elements in natural samples.

  • PDF