• 제목/요약/키워드: dilution

검색결과 2,380건 처리시간 0.037초

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

Estimation in Group Testing when a Dilution Effect exists

  • Kwon, Se-Hyug
    • Communications for Statistical Applications and Methods
    • /
    • 제13권3호
    • /
    • pp.787-794
    • /
    • 2006
  • In group testing, the test unit consists of a group of individuals and each group is tested to classify units from a population as infected or non-infected or estimate the infection rate. If the test group is infected, one or more individuals in the group are presumed to be infected. It is assumed in group testing that classification of group as positive or negative is without error. But, the possibility of false negatives as a result of dilution effects happens often in practice, specially in many clinical researches. In this paper, dilution effect models in group testing are discussed and estimation methods of infection rate are proposed when a dilution effect exists.

EVALUATION OF TECHNIQUES FOR ESTIMATING MILK PRODUCTION BY SOWS 1. DEUTERIUM OXIDE DILUTION METHOD FOR ESTIMATING MILK INTAKE BY PIGLETS

  • Prawirodigdo, S.;King, R.H.;Dunkin, A.C.;Dove, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권2호
    • /
    • pp.135-141
    • /
    • 1990
  • Two experiments were conducted to determine the validity of the deuterium oxide ($D_2O$) dilution method to estimate milk intake by pigs. A total of 39 piglets weaned from their dams 24 - 36 hours after birth and trained to drink from artificial nipples, were used for two experiments. Estimates of milk replacer consumption of individual piglets over 1, 3, 5 and 7 days were made by the $D_2O$ dilution method and by dissappearance. Milk intakes estimated by this $D_2O$ dilution method were significantly correlated ($R^2$ = 0.98-0.99) with milk intake measured by disappearance. The average difference between estimates by disappearance and estimates by the $D_2O$ dilution method were -1%, +0.5%, +0.5% and -2.1% for measurement period of 1, 3, 5 and 7 days respectively.

예열공기온도와 희석비율에 따른 동축 확산 화염의 연소 특성 (Combustion characteristics of coaxial diffusion flame with preheated air temperature and dilution level)

  • 김진식;곽지현;전충환;장영준
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.51-56
    • /
    • 2001
  • An experiment using preheated air in the coaxial diffusion flame burner was carried out in order to decrease NOx emission and improve the thermal efficiency. Preheated air combustion generally produces high NOx emissions but it was known very well to reduce NOx emission by diluting the combustion air with inert gas in preheated air combustion. In our study, $N_2$ gas was used for diluent and propane was utilized for fuel. We set the combustion air temperature on 300K, 500K, 700K, 900K and dilution level from 21% to 10% in terms of oxygen concentration. NOx emission increased along increment of combustion air temperature and decreased along increment of dilution level(lowering of oxygen concentration in combustion air). Flame-off limit with dilution level enhanced, flame length became longer and the location of maximum flame temperature became lower with increasing of combustion air temperature.

  • PDF

Effect of dilution on micro hardness of Ni-Cr-B-Si alloy hardfaced on austenitic stainless steel plate for sodium-cooled fast reactor applications

  • Balaguru, S.;Murali, Vela;Chellapandi, P.;Gupta, Manoj
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.589-596
    • /
    • 2020
  • Many components in the assembly section of Sodium-cooled Fast Reactor are made of good corrosionresistant 316 LN Stainless Steel material. To avoid self-welding of the components with the coolant sodium at elevated temperature, hardfacing is inevitable. Ni-based colmonoy-5 is used for hardfacing due to its lower dose rate by Plasma Transferred Arc process due to its low dilution. Since Ni-Cr-B-Si alloy becomes very fluidic while depositing, the major height of the weld overlay rests inside the groove. Hardfacing is also done over the plain surface where grooving is not possible. Therefore, grooved and ungrooved hardfaced specimens were prepared at different travel speeds. Fe content at every 100 ㎛ of the weld overlay was studied by Energy Dispersive Spectroscopy and also the micro hardness was determined at those locations. A correlation between iron dilution from the base metal and the micro hardness was established. Therefore, if the Fe content of the weld overlay is known, the hardness at that location can be obtained using the correlation and vice-versa. A new correlation between micro hardness and dilution coefficient is obtained at different locations. A comparative study between those specimens is carried out to recommend the optimum travel speed for lower dilution.

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

이염화이소시아뉼산나트륨 제재의 근관세척액 사용 가능성 평가;염소이온농도, 세포독성, 항균성 및 pH (EVALUATION OF SODIUM DICHLOROISOCYANURATE AS A ROOT CANAL IRRIGATION SOLUTION;Cl- CONCENTRATION, pH, CYTOTOXICITY AND ANTIMICROBIAL EFFECT IN VITRO)

  • 이우철;강봉선;김철호;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.425-430
    • /
    • 2003
  • The purpose of this study was to evaluate the clinical applications of the Sodium Dichloroisocyanurate effervescent tablet as a routine root canal irrigant by performing several in vitro tests such as $Cl^{-}$ content. cytotoxicity. antimicrobial effect as well as its pH level compared to the equivalent concentration of sodium hypochlorite solution. 1. Sodium Dichloroisocyanurate demonstrated lower level of $Cl^{-}$ concentration than each dilution of sodium hypochlorite solution. Both solution has increased level of $Cl^{-}$ as the concentration of each solution increased. There was no significant change of $Cl^{-}$ concentration in sodium hypochlorite as time goes by. However. $Cl^{-}$ concentration in Sodium Dichloroisocyanurate was increased. 2. The antimicrobial effects of both solutions were increased when their concentrations were increased. One day after dilution. antimicrobial effect of Sodium Dichloroisocyanurate was slightly higher than sodium hypochlorite. however. there was no difference in 1 week dilution solution. One month dilution solution of sodium hypochlorite still retain its activity. but antimicrobial effect of Sodium Dichloroisocyanurate was drastically decreased 1 month after dilution. 3. The cytotoxicity of Sodium Dichloroisocyanurate was rather higher than same concentration of sodium hypochlorite solution until 1 week after dilution. Then in 1 month. cytotoxicity of Sodium Dichloroisocyanurate was decreased than that of 1 week dilution solution. especially 4% Sodium Dichloroisocyanurate solution has almost no toxicity. However. 1% and 2% sodium hypochlorite solution has unchanged moderate degree of cytotoxicity after the dilution. Furthermore. 4% sodium hypochlorite solution showed high level of toxicity. 4. The pH level of Sodium Dichloroisocyanurate showed that the solution was weak acid (pH5). On the other hand. sodium hypochlorite was revealed as a strong alkaline solution (pH12). There was no change in pH following the dilution of each solution. As results. Sodium Dichloroisocyanurate solution fully satisfy the basic requirements as a root canal irrigation solution. However. we strongly recommend to use this solution clinically in low concentration and try to apply into the root canal within 1 week after dilution.

오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구 (The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes)

  • 김한수;이석준;김선태
    • 대한환경공학회지
    • /
    • 제35권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 본 연구는 냄새 농도 평가를 위한 공기희석관능법의 단계별 희석가스 제조방법에 관한 것으로, 시료가스와 무취가스를 오리피스 튜브로 조절하여 희석하는 방법에 관한 것이다. 10배 및 30배 희석용 오리피스 튜브를 설계하고, 10, 30, 100, 300 및 1,000배 등의 단계별 희석가스를 10배 및 30배 희석용 오리피스 튜브를 반복적으로 사용하여 다양한 희석배율의 희석가스를 제조할 수 있다. 10배 희석용 오리피스 튜브의 홀 크기는 0.84 mm, 30배 희석용 오리피스 튜브의 홀 크기는 0.32 mm로 제작하였다. 제작된 냄새 평가를 위한 시료가스 희석용 오리피스 튜브에 의한 제조된 희석가스의 균질성은 2%RSD 내외로 우수한 재현성을 확인하였다. 또한, 기존 주사기를 이용하는 공기희석관능법에 의해 제조된 희석가스 농도와 비교하여 90% 이상의 상관성을 보이고 있었다. 진공펌프의 유량 변화에 따른 희석가스의 농도변화가 없이 간단히 진공흡인상자의 전단에 설치하여 활용할 수 있어 향후 다양한 현장 적용 평가 및 공기희석관능법과의 비교 연구를 통하여 현장에서의 복합악취 등의 평가에 활용할 수 있을 것으로 기대된다.

마산.창원 하수종말처리장 증설에 따른 근역희석률변화 예측 (Prediction of Near-Field Dilution Changes Due to Treatment Capacity Expansion of Masan-Changwon Municipal Wastewater Treatment Plant)

  • 유승협
    • 한국해안해양공학회지
    • /
    • 제12권2호
    • /
    • pp.53-69
    • /
    • 2000
  • 수중다공확산관을 통해 1차 처리수를 마산만에 방류하고 있는 마산·창원 하수종말처리장의 증설계획에 따른 하수방류량의 증가시 현재의 해양방류시설을 그대로 사용하였을 경우 방류하수의 희석률 변화를 예측하였다 하수처리시설 증설후 방류량의 증가에 따라 희석률은 큰 폭으로 감소하였다 이에 대한 개선방안 도출을 위해 현 위치에서 확산관의 배치와 길이를 변경해서 희석률의 개선효과를 CORMIX 모형을 사용하여 조사하였다. 확산관의 길이가 연장되고 확산관축을 해류방향에 대해 평행보다는 직각이 되게 배치했을 경우 희석률은 다소 증가하였으나 소조기의 약한 해류에서는 희석률의 변화가 거의 없어 현위치에서의 한계성을 보였다 하수처리장의 2단계와 3단계의 증설에 대비한 새로운 방류위치선정과 확산관의 최적배치로 희석률을 크게 높일수 있는 대안을 모형 모의 결과로부터 제시하였다.

  • PDF

정지수체로 방류된 연직다중\ulcorner㈏\ulcorner최소희석률 (Minimum Dilution of Vertical Multijet Discharging into Stagnant Water)

  • 김홍식;서일원;유대영;서용원
    • 한국수자원학회논문집
    • /
    • 제32권2호
    • /
    • pp.153-162
    • /
    • 1999
  • 본 연구에서는 정지수체에서 다공확산관을 통해 방류된 연직다중의 혼합 및 희석 특성에 대해 규명하였다. 3차원 실험수조에서 실험을 통해 밝혀진 결과는 다음과 같다. 우선 다공확산관의 병합과정을 살펴보면 흐름의 안정조건에 따라 병합거리가 다소 차이가 있기는 하지만 {{{{ { z}_{ } }}}}/{{{{ {l}_{ } }}}}가 대략 3인 지점부터 병합이 시작되어 그 이후에는 평면부력?의 거동에 서서히 가까워짐을 알 수 있다. 최소희석률에 대해 분석해 본 결과, 방류운동량이 지배적인 영역, 천이영역, 그리고 부력이 지배적인 부력류영역으로 나누어 희석률 특성을 표현할 수 있음을 알 수 있었다. 본 연구의 실험결과 다공확산관의 경우 부력류영역의 희석률 상수가 평면확산관에 비해 15% 더 높게 나왔다. 그 이유는 다공확산관의 경우 병합 이전에는 개별의 경계면에서 주변수의 포획이 발생하여 희석이 증대되기 때문이다.

  • PDF