• Title/Summary/Keyword: digital relay

Search Result 272, Processing Time 0.024 seconds

Modified Current Differential Relay for $Y-{\Delta}$ Transformer Protection ($Y-{\Delta}$ 변압기 보호용 수정 전류차동 계전기)

  • Jin, En-Shu;Kang, Yong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.95-101
    • /
    • 2006
  • This paper proposes a modified current differential relay for $Y-{\Delta}$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation, because the exciting current was successfully compensated. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay does not require additional restraining signal and thus cause time delay of the relay.

An Implementation of Generator Protective Relay for Real Time Digital Simulator (실시간 전력계통 시뮬레이터를 이용한 발전기 보호 계전기 모델 개발)

  • Cho, Yoon-Sung;Park, Sung-Woo;Lee, Chul-Kyun;Lee, Uk-Hwa;Kim, Tae-Kyun;Shin, Jeong-Hoon;Cha, Seung-Tae;Choi, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.240-247
    • /
    • 2007
  • This paper presents an implementation of the generator protective relay using Real Time Digital Simulator (RTDS) user defined component (UDC) model designed to facilitate the investigation and evaluation of protective relays. The UDC for RTDS is a convenient model that allows user to develop new component models and run them on the RTDS. The developed model has major features related to the development of six models such as distance, frequency, reverse power, volts per Hz, over voltage, and out-of-step relays. Also, the generator relay models have been used to support and enhance power engineering education at both the undergraduate and graduate levels. The developed model functions are verified and tested by both static test and dynamic test. The simulation results show the capabilities of the developed generator relay using RTDS UDC.

Estimation of Delta Winding Current and Its Application to a Compensated-Current-Differential Relay for a Y-Δ Transformer

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, En-Shu
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.255-263
    • /
    • 2010
  • The compensated-current-differential relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Delta winding current is necessary to obtain the modified differential current for a $Y-\Delta$ transformer. This paper describes an estimation algorithm of the delta winding current and its application to a compensated-current-differential relay for a $Y-\Delta$ transformer. Prior to saturation, the core-loss current is calculated and used to modify the differential current. When the core first enters saturation, the initial value of the core flux is obtained by inserting the modified differential current into the magnetization curve. This flux value is used to derive the magnetizing current and consequently the modified differential current. The operating performance of the proposed relay was compared against a conventional current differential relay with harmonic blocking. Test results indicate that the proposed relay remained stable during severe magnetic inrush and over-excitation, and its operating time is significantly faster than a conventional relay. The relay is unaffected by the level of remanent flux and does not require an additional restraining or blocking signal to maintain stability. This paper concludes by implementing the proposed algorithm into a prototype relay based on a digital signal processor.

Exploiting Multi-Hop Relaying to Overcome Blockage in Directional mmWave Small Cells

  • Niu, Yong;Gao, Chuhan;Li, Yong;Su, Li;Jin, Depeng
    • Journal of Communications and Networks
    • /
    • v.18 no.3
    • /
    • pp.364-374
    • /
    • 2016
  • With vast amounts of spectrum available in the millimeter wave (mmWave) band, small cells at mmWave frequencies densely deployed underlying the conventional homogeneous macrocell network have gained considerable interest from academia, industry, and standards bodies. Due to high propagation loss at higher frequencies, mmWave communications are inherently directional, and concurrent transmissions (spatial reuse) under low inter-link interference can be enabled to significantly improve network capacity. On the other hand, mmWave links are easily blocked by obstacles such as human body and furniture. In this paper, we develop a multi-hop relaying transmission (MHRT) scheme to steer blocked flows around obstacles by establishing multi-hop relay paths. In MHRT, a relay path selection algorithm is proposed to establish relay paths for blocked flows for better use of concurrent transmissions. After relay path selection, we use a multi-hop transmission scheduling algorithm to compute near-optimal schedules by fully exploiting the spatial reuse. Through extensive simulations under various traffic patterns and channel conditions, we demonstrate MHRT achieves superior performance in terms of network throughput and connection robustness compared with other existing protocols, especially under serious blockage conditions. The performance ofMHRT with different hop limitations is also simulated and analyzed for a better choice of the maximum hop number in practice.

Power Quality Monitoring Algorithm Using the Protective Relay (보호계전기를 이용한 전기 품질 감시 기법 연구)

  • Choi In. S.;Lee Kang. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

A Study on Directions for Developing TV Sports Relay Broadcasting - With a focus on golf relay broadcasting on TV - (TV스포츠 중계방송 제작 방향에 관한 연구 - 골프중계방송을 중심으로 -)

  • Yang, jin-myeon;Yang, jong-hoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.563-564
    • /
    • 2011
  • 본 연구는 TV스포츠 중계방송 중에서 골프중계방송제작에 필요한 영상제작구성과 스포츠 중계방송의 발전방향에 대하여 기술하였다.

  • PDF

A Study on the Cross-Polarization Interference Canceller of Radio Relay System for Spectral Efficiency Enhancement (주파수 효율 향상을 위한 무선 중계장치의 직교편파 간섭제거기에 관한 연구)

  • 서경환
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.25-28
    • /
    • 2001
  • In this paper. to eliminate a cross-polarization interference caused by co-channel dual polarization technique of digital radio relay system(DRRS), a cross-polarization interference canceller(XPIC) is analysed in terms of the analytical modeling, digital design, and its performance. By virtue of a 13-tap adaptive equalizer and XPIC, about 23dB in XPIC improvement can be obtained by computer simulation. To show the operation of designed XPIC, some simulated results are reviewed under 64-QAM DRRS with co -channel dual Polarization.

  • PDF

Reliability Prediction of Digital Protection Relay (디지털 보호계전기의 신뢰도 분석)

  • Song, In-Jun;An, Yong-Ho;Yang, Gwi-Jang;Jun, Kwang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.377-378
    • /
    • 2008
  • 한전에서는 계통보호 설비의 신뢰도 확보를 위해 디지털 보호설비 사용을 확대하고 있으며, 이에 따른 합리적인 보호설비 교체기준을 설정하려고 한다. 본 논문에서는 디지털 보호계전기의 교체기준 설정을 위해 디지털 보호 계전기(Digital Distance Relay)와 구성모듈에 대한 고장률(Failure rate)과 평균수명(Mean Time between Failures, MTBF), 그리고 시간에 따른 신뢰도를 분석하였다. 수명예측방법은 MIL-HDBK-217F, Notice 2의 부품스트레스분석방법(Part Stress Analysis Method) 사용하였다.

  • PDF

Realtime Digital Monitoring and Controller Development for Power Systems (전력시스템의 실시간 디지털 중앙감시 및 제어장치 개발)

  • Jong-Dug Cho;Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1517-1522
    • /
    • 2001
  • In this paper, We propose digital protective relay which monitors the status of distribution line and controls power apparatus with real time operation. Digital protective relay improves the performance of basic functions which are measurement, display and communication. The Int one we consider is that the protective device has the standard method for protecting the distribution systems which are circuit brakers, switch and emergency generators. These are Protected by analog type Protective relay and devices. The security requirements should be activated within a few seconds, and with real time operation. The second one is an efficient method for adapting the one chip micro-processor(PIC16F84) which is enable to digital control system. The proposed methods are implemented with experimental results and have an high fidelity characteristics in local experiment tests.

  • PDF

A Study on the Design of Cross-Polarization Interference Canceler for Digital Radio Relay System with Co-Channel Dual Polarization (동일 채널 이중편파를 적용하는 디지털 무선 중계장치의 직교편파간섭제거기 설계에 관한 연구)

  • 서경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.225-236
    • /
    • 2002
  • In this paper, to counteract a cross-polarization interference caused by co-channel dual polarization technique of digital radio relay system(DRRS), we analyze the theoretical model and digital design of cross-polarization interference canceller(XPIC). In addition a complex adaptive time domain equalizer(ATDE) is designed using a finite impulse response filter, and the structure of XPIC and its control method are also illustrated including ATDE. Our computer simulation shows that about 25 dB signature and more than 23 dB XPIC improvement factor can be obtained with XPIC and ATDE. In order to verify the operation of designed XPIC, we review the simulated results in view of tap number, algorithm convergence, system signature, and XPlC improvement factor in connection with 64-QAM DRRS with co-channel dual polarization.