• Title/Summary/Keyword: digital lines

Search Result 470, Processing Time 0.027 seconds

An Study on Effective Maintenance and Operation System of Fiber Optic Lines (효과적인 광선로 유지 보수를 위한 시스템 개발에 관한 연구)

  • Jang, Eun-Sang;Park, Kap-Seok;Kim, Seong-Il;Choi, Sin-Ho;Lee, Byeong-Wook
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.54-57
    • /
    • 1998
  • As the physical layer on telecommunication network is replaced fiber optic lines, it is increased the need of systematic maintenance for fiber optic lines. Korea Telecom has developed FLOMS in order to establish maintenance processes for optical fiber lines. FLOMS has functions which manages optical facilities and tests optical fiber lines automatically. As a resuls, this system can check and/or report a fault. Operator, who is reponsible for management of optical fiber lines, can test the characteristics of optical fiber lines remotely using FLOMS. As interpoerable with Digital Transmission Management System, FLOMS provides efficient management for optical fiber lines. This system improves the work process to find fault location fast, detect the degradation of fiber quality, and make database of optical facilities efficiently.

  • PDF

Adjustment of 1st order Level Network of Korea in 2006 (우리나라 1등 수준망 조정(2006년))

  • Lee, Chang-Kyung;Suh, Young-Cheol;Song, Chang-Hyun;Jeon, Bu-Nam
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.7-10
    • /
    • 2007
  • The 1st order vertical network of Korea was adjusted in 1987 at first time. This is the second adjustment of the 1st order vertical network of Korea by National Geographic Information Institute. All the levelling data were acquired by digital level with invar staff. The number of 1st order level lines are 36, and 34 level lines comprise 11 circles of level network. Backward and forward error of a few level lines are larger than the regulations of NGII, Korea. Also, 3 circles of vertical network has circuit closure error that is exceed the regulation. As the result of 1st order vertical network adjustment, the reference standard error of the vertical network was $1.8mm/{\surd}km$.

  • PDF

디지탈 영상처리를 이용한 광탄성 프린지의 세선화처리

  • 백태현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.127-133
    • /
    • 2001
  • Photoelastic isochromatic fringes related to the difference of principal stresses have some bandwidth whose light intensities are not constant and unsymmetrical in experimental image. Hence it is difficult to measure fringe order accurately at a data point by visual observation. In this study, the method of fringe sharpening, which can extract sharpened lines from both full-and half-order fringes by digital image processing, is developed. To test the method, various simple photoelastic fringe patterns are simulated and their image are processed to yield sharpened lines. The method is than applied to general problem such as image of a circular disk compressed by concentrated loads and a cylinder subjected to internal pressure. The procedure is proved to be capable of extracting sharpened lines accurately from photoelastic isochromatic fringes.

A Two-bit Bus-Invert Coding Scheme With a Mid-level State Bus-Line for Low Power VLSI Design

  • Yoon, Myungchul
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.436-442
    • /
    • 2014
  • A new bus-invert coding circuit, called Two-bit Bus-Invert Coding (TBIC) is presented. TBIC partitions a bus into a set of two-bit sub-buses, and applies the bus-invert (BI) algorithm to each sub-bus. Unlike ordinary BI circuits using invert-lines, TBIC does not use an invert-line, so that it sends coding information through a bus-line. To transmit 3-bit information with 2 bus-lines, TBIC allows one bus-line to have a mid-level state, called M-state. TBIC increases the performance of BI algorithm, by suppressing the generation of overhead transitions. TBIC reduces bus transitions by about 45.7%, which is 83% greater than the maximum achievable performance of ordinary BI with invert-lines.

A New Distance Relaying Algorithm for Phase-to-Ground Fault in 765kV Untransposed Transmission Lines (765kV 비연가 송전선로에서 단상지락고장 시어 거리개전 알고리즘)

  • AHN YONG JIN;KANG SANG HEE
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.452-454
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-ground fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for Phase-to-ground fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

A New Distance Relaying Algorithm for Phase-to-Phase Short Fault in 765kV Untransposed Transmission Lines (765kV 비연가 송전선로에서 상간단락고장 시어 거리계전 알고리즘)

  • AHN YONG JIN;KANG SANG HEE
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.455-457
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-phase short fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-phase short fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kv untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

The Technology of Gigabit Interconnects for Communication Systems (통신시스템 기가비트 연결 설계기술)

  • 남상식;박종대
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.149-153
    • /
    • 1999
  • As VLSI technology advances rapidly, the operating frequency of digital systems becomes very fast. In such a high-speed system, there are many factors that threaten signal integrity. The noise sources in digital system include the noises in power supply, ground bounce and packaging media and distortions on single and multiple transmission lines. This paper will present a technology survey useful in the design of Gigabit interconnection systems. Some case studies have been constructed which show the lossy transmission line effect of skin effect. dielectric loss, with backplane connectors using the theoretical and practical conditions.

  • PDF

An Effective Echo Canceller for Asymmetric Digital Subscriber Lines (비대칭 디지털 가입자회선을 위한 효율적인 반향 제거기)

  • 권오상;조계옥;이기원
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.55-58
    • /
    • 1999
  • For the asymmetric digital subscriber line communications, the paper proposes a new echo canceller with the so-called CALAOI(CAscade of LAttice and Orthogonalized IIR) structure, which comprises of a lattice and an orthogonalized IIR structure. Through simulations, the CALAOI echo canceller was verified to have much fewer complexity of computations and has faster convergence speed than conventional FIR echo canceller. The CALAOI echo canceller is predicted to maximize performances of communication services in high speed communications such as VDSL, GIGA bit Ethernet, and so on as well as ADSL.

  • PDF

Analysis of High-Speed Pulse Propagation on Arbitrarily Interconnected Transmission Lines by an Efficient Node Discretization Technique (효율적인 노드분할법을 통한 임의 결선된 전송선로상의 고속 펄스 전송 해석)

  • 전상재;박의준
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.1
    • /
    • pp.37-46
    • /
    • 2003
  • The transient responses on arbitrarily interconnected digital transmission lines are analyzed by an efficient node discretization technique. Since the proposed node discretization technique offers an efficient means to discretize transmission lines, the transient waveform at any position on the arbitrarily interconnected lines is easily predicted. Dispersive microstrip multiconductor transmission lines arbitrarily connected are analized for generality. The derivation of frequency-dependent equivalent circuit elements of coupled transmission lines have been carried out by the spectral domain approach(SDA). The effects of variations of excited pulse width on the crosstalks of the high-speed microstrip coupled-lines are also investigated. It has been well known that the crosstalk spike level is monotonously increased when the coupling length and effective permittivity of substrate are increased. In this paper, it is found that the variations of crosstalk level are not further monotonous as shortening the exciting pulse width toward several picosecond. The results are verified by the generalized S-parameter technique.

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.