• Title/Summary/Keyword: digital lines

Search Result 469, Processing Time 0.025 seconds

A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System (평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법)

  • Kim, Gyu-Won;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

Properties of Merging Galaxies in the Nearby Universe

  • Park, Jong-Han;Ann, Hong-Bae;Kang, Hye-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.70.1-70.1
    • /
    • 2011
  • We have investigated properties of merging galaxies in the nearby universe, using Sloan Digital Sky Survey (SDSS) DR7. We first constructed two galaxy samples according to redshift range: Sample 1 for 0 ${\leq}$ z ${\leq}$ 0.025 and Sample 2 for 0.09 ${\leq}$ z ${\leq}$ 0.1. We then identified 118 and 184 merging galaxies among the galaxies in the Sample 1 and 2, respectively, and classified them into different merging types and stages by visual inspection of galaxy images. In the Sample 1, there are more wet mergers than dry mergers, while most merging galaxies in the Sample 2 are dry mergers. The color-magnitude diagram of the merging galaxies in our samples is comparable to that of normal galaxies. Dry mergers tend to locate in the red sequence, while wet and mixed mergers reside mostly in the blue cloud. Unlike some previous studies, we did not find a clear trend that the merger rate increases at higher redshift. However, it is difficult to make a direct comparison of the merger rate found in different studies, because it depends on the number of observed galaxies and criteria for merger classification. From the ratios of emission lines, we infer that the faction of merging galaxies with AGNs is higher in wet mergers than in other types.

  • PDF

A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables (웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

Condition assessment of reinforced concrete bridges using structural health monitoring techniques - A case study

  • Mehrani, E.;Ayoub, A.;Ayoub, A.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.381-395
    • /
    • 2009
  • The paper presents a case study in which the structural condition assessment of the East Bay bridge in Gibsonton, Florida is evaluated with the help of remote health monitoring techniques. The bridge is a four-span, continuous, deck-type reinforced concrete structure supported on prestressed pile bents, and is instrumented with smart Fiber Optic Sensors. The sensors used for remote health monitoring are the newly emerged Fabry-Perot (FP), and are both surface-mounted and embedded in the deck. The sensing system can be accessed remotely through fast Digital Subscriber Lines (DSL), which permits the evaluation of the bridge behavior under live traffic loads. The bridge was open to traffic since March 2005, and the collected structural data have been continuously analyzed since. The data revealed an increase in strain readings, which suggests a progression in damage. Recent visual observations also indicated the presence of longitudinal cracks along the bridge length. After the formation of these cracks, the sensors readings were analyzed and used to extrapolate the values of the maximum stresses at the crack location. The data obtained were also compared to initial design values of the bridge under factored gravity and live loads. The study showed that the proposed structural health monitoring technique proved to provide an efficient mean for condition assessment of bridge structures providing it is implemented and analyzed with care.

Transmission Characteristics Analysis of Digital Pulse Signal on Tapered Microstrip Line in Time Domain (테이퍼형 마이크로 스트립 선로에서 디지털 펄스 신호의 시간 영역 전송 특성 해석)

  • Kim, Gi-Rae
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.1-6
    • /
    • 1999
  • The only transmission characteristics in frequency domain is considered when using the tapered transmission line for wide-band impedance matching in MCM and MIC designs. In this paper, the distortion of an electrical pulse with rise/fall time resulting from dispersion and reflection as it propagates along a tapered microstrip line is investigated, and the delay time and distortion rate with respect to input and load impedances are analyzed on triangular and exponential tapered lines. A dispersion model of the phase constant proposed by Kirschning-Jansen is used to meet the frequency, accuracy and microstrip parametric requirements. The triangular tapered line shows both shorter delay time and higher distortion rate than those of the exponential tapered line. Furthermore, the amplitude of signal reflected from load point is calculated in time domain.

  • PDF

The Development of Dual Structured Power Management System (이중화 구조를 가진 변전소자동화시스템의 개발)

  • Woo, Chun-Hee;Lee, Bo-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.275-288
    • /
    • 2010
  • In order to improve the quality of electricity in large scale power systems, stability of power system has to be achieved. This can be done by the means of preventative diagnosis of power equipments and protection, monitoring and control of the power system. Since the recent adoption of digital controllers, an improvement in stability was observed; in particular, IED, which contained self-diagnostic abilities such as fault tolerance, allowed for automatic recovery via redundancy or switching-over functions should there be faults with the equipments. Furthermore, communication lines have been hugely simplified, thus adding to the improvement in stability significantly. Taking these error reports and forecasting emergency reports and by effectively responding to them in the overiding controlling systems, high levels of system stability can be obtained. Power Management System that is being applied to automated power sub-stations, takes the IEC61850 international standard as its specification. In this paper, additional research into achieving stability of already developed PMS system and also the stability of the overall system was carried out, and the results of development of communication servers, which play a pivotal role in connecting systems, are stated.

An Equivalent Load Sharing by Wireless Parallel Operation Control in UPS

  • Byun, Young-Bok;Koo, Tae-Geun;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • Journal of KIEE
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • An equivalent load sharing control based on the frequency and voltage droop concept for parallel operation of two three-phase Uninterruptible Power Supply (UPS) systems with no control interconnection lines is presented in this paper. First of all, due to the use of active power and reactive power as control variables, the characteristics of output powers according to amplitude and phase differences between output voltages of two UPS systems are analyzed. Secondly, simulation results under different line impedance demonstrate the feasibility of the wireless parallel operation control. Finally, experiments are presented to verify the theoretical discussion with two three-phase 20kVA UPS systems employed TMS320C32, a kind of real time digital signal processor (DSP).

  • PDF

Real-time Synchronization Between Two Industrial Dual-arm Robots (두 개의 산업용 양팔로봇간의 실시간 동기화 방법)

  • Choi, Taeyong;Kyung, Jinho;Do, Hyunmin;Park, Chanhun;Park, Dongil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1027-1033
    • /
    • 2016
  • There is an increasing need for manufacturing systems to produce batches in small quantities. Such manufacturing systems are significantly difficult to develop with conventional automation equipment. Recently, several research groups have applied industrial dual-arm robots to cell production lines. A synchronization method for robots is necessary for the cell production process when robots work in a shared workspace. Conventional automation factories do not need this method because the main control system operates all of the machines or robots. However, our intended application for the developed robot is in small manufacturing environments that cannot install an expensive main control system. We propose an inexpensive and high-performance method with a simple digital in/out channel using a real-time communication protocol. The developed method was validated in a pilot production line for cellular phone packing.

Electromagnetic Field Analysis of Magnetic Bearing due to Stator Structure (스테이터 구조에 의한 마그네틱 베어링의 전자장해석)

  • Kim, Ki-Joon;Shin, Cheol-Gi
    • 전자공학회논문지 IE
    • /
    • v.48 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this study, it carried out Electromagnetic Field Analysis of Magnetic Bearing due to stator structure and it got the electrical characteristics of 3 structure types of AMB(Active magnetic bearing) systems to get optimal design criteria. The results of simulation in three types of AMB, using FEM method, type 1, 2, and 3 had many paths to move magnetic flux vectors from N pole to S pole and magnetic flux lines are transferred to rotor as a shaft. The paths help to rotate the rotors. So, their data of electrical properties carry out design of magnetic bearing system and the data help to make design criteria.

A RELATION BETWEEN ACTIVE BLACK HOLES AND STAR FORMATION OF LOCAL ACTIVE GALAXIES

  • MATSUOKA, KENTA;WOO, JONG-HAK;BAE, HYUN-JIN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.341-343
    • /
    • 2015
  • We present an analysis of the relation between star-formation (SF) and accretion luminosities of local type-2 active galactic nuclei (AGNs) at $0.01{\leq}z<0.22$. We match type-2 AGNs found in the Sloan Digital Sky Survey to current far-infrared (FIR) survey catalogues based on AKARI and Herschel. Estimating AGN luminosities from [$O{\small{III}}$]${\lambda}5007$ and [$O{\small{I}}$]${\lambda}6300$ emission lines, we find a positive linear trend between FIR and AGN luminosities over a wide dynamical range. This result appears to be inconsistent with recent reports that low-luminosity AGNs show no correlation between FIR and X-ray luminosities; this contradiction is likely due to Malmquist and sample selection biases. Moreover, we also find that pure-AGN candidates, for which the FIR radiation is thought to be AGN-dominated, show significant low-SF activities. These AGNs hosted by low-SF galaxies are rare in our sample. However, it is possible that the low fraction of low-SF AGN is caused by observational limitations, as recent FIR surveys are not sufficient to examine the population of high-luminosity AGNs hosted by low-SF galaxies.