• Title/Summary/Keyword: digital inspection

Search Result 353, Processing Time 0.027 seconds

A Study on HSTPA Model for Improvement of Emergency Response Training for Ships (선박의 비상대응훈련 개선을 위한 HSTPA 모델에 관한 연구)

  • Han, Ki-Young;Jung, Jin-ki;Ahn, Young-Joong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.441-447
    • /
    • 2019
  • Since emergency response training for maritime safety and safety education of maritime education institutions are conducted based on the set scenarios and education contents, there are limitations in the reduction of human error and response to various situations. Although there is a need for improvement, there is no way to improve response capabilities by assessing existing education training and securing diversity in situations. This study proposes a theoretical procedure analyzer method to model the diversity of situations for the improvement of emergency response training. This paper defines the human and system theoretical procedure analysis model (HSTPA) based on the organic relationship of the source and system. The limitations of the existing training were derived by analyzing the errors that each component could produce and applying them to the fire response training scenarios requiring vertical reporting systems and responses. The segmentation and inspection of training scenario considerations applying the proposed HSTPA model is believed to help create diverse and realistic scenarios in emergency response training and education, and improve the situation judgment understanding and response capabilities of the subjects.

Status of Government Funded Projects for "Laboratory Safety" ('연구실 안전' 관련 정부연구개발사업 동향 분석)

  • Suh, Jiyoung;Kim, Hyemin;Bae, Sunyoung;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.396-416
    • /
    • 2021
  • Objectives: This study was conducted to analyze the trends of government R&D (R&D) projects related to laboratory safety over the past 20 years. Methods: We collected publications from various databases(DBs) with words such as laboratory(ies), lab(s), researcher(s), laboratory worker(s), safety, environment, hazard(s), risk(s), and so on. Selected publications were analyzed by the research funds and the number of projects according to the investment subject and research characteristics. Results: About 93% of the total R&D budget went to government policy projects, not scientific research. Second, from the perspective of 'safety management activities', most of the research is related to management and inspection at the organizational level. Issues that need to be discussed at the national level like policy governance are not included. Third, focusing on the 'safety management cycle', there were few studies related to 'prediction' or 'post-response'. Fourth, when an analysis framework combining the perspectives of 'safety management activities' and 'safety management cycle' is applied, most of the budget is spent on infrastructure such as digital management systems, whereas basic knowledge for prevention and production of evidence was very few. Conclusions: In order to prevent policy planning without policy evaluation, implementation without strategy, and evaluation without evidence, it is necessary to expand investment in empirical research on risks, research on the effectiveness of current application methods, and research on theory development. The government budget for laboratory safety-related projects should be managed separately from the R&D budget for scientific research. Although less than 5% of the budget allocated to scientific research is the total budget, an optical illusion occurs because both the project budget and the scientific research budget are counted as R&D budgets.

Evaluation of Crack Monitoring Field Application of Self-healing Concrete Water Tank Using Image Processing Techniques (이미지 처리 기법을 이용한 자기치유 콘크리트 수조의 균열 모니터링 현장적용 평가)

  • Sang-Hyuk, Oh;Dae-Joong, Moon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.593-599
    • /
    • 2022
  • In this study, a crack monitoring system capable of detecting cracks based on image processing techniques was developed to effectively check cracks, which are the main damage of concrete structures, and a program capable of imaging and analyzing cracks was developed using machine vision. This system provides objective and quantitative data by replacing the appearance inspection that checks cracks with the naked eye. The verification of the development system was applied to the construction site of a self-healing concrete water tank to monitor the crack and the amount of change in the crack width according to age. In the case of crack width detected by image analysis, the difference from the measured value using a digital microscope was up to 0.036 mm, and the crack healing effect of self-healing concrete could be confirmed through the reduction of crack width.

A Development of Unbalanced Box Stacking System with High Stability using the Center of Gravity Measurement (무게중심 측정을 이용한 불평형 상자의 고안정 적재 시스템 개발)

  • Seong-Woo Bae;Dae-Gyu Han;Jae-Ho Ryu;Hyeon-hui Lee;Chae-Hun An
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.229-237
    • /
    • 2024
  • The logistics industry is converging with digital technology and growing into various logistics automation systems. However, inspection and loading/unloading, which are mainly performed in logistics work, depend on human resources, and the workforce is shrinking due to the decline in the productive population due to the low birth rate and aging. Although much research is being conducted on the development of automated logistics systems to solve these problems, there is a lack of research and development on load stacking stability, which has the potential to cause significant accidents. In this study, loading boxes with various sizes and positions of the center of gravity were set up, and a method for stacking that with high stability is presented. The size of the loading box is measured using a depth camera. The loading box's weight and center of gravity are measured and estimated by a developed device with four loadcells. The measurement error is measured through various repeated experiments and is corrected using the least squares method. The robot arm performs load stacking by determining the target position so that the centers of gravity of the loading boxes with unbalanced masses with a random sequence are transported in alignment. All processes were automated, and the results were verified by experimentally confirming load stacking stability.

Ergonomic Approach through Process Analysis of Delivery Work (택배 배송 작업의 공정분석을 통한 인간공학적 접근 방안)

  • Sejung Lee;Sangeun Jin;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2024
  • In response to the COVID-19 pandemic, the logistics industry in Korea has rapidly been expanding, with offline demand concentrating on online platforms owing to the development of digital infrastructure. This has increased the workload of courier drivers considerably, along with labor intensity. A delivery driver died recently from overwork due to the continuous increase in delivery volume, which raises social concerns. Delivery drivers work long hours, (over 12 hours) and are greatly affected by weather conditions, such as snow, rain, heat waves, and cold waves. In addition, they lack a fixed workplace; perform atypical work handling workpieces of various sizes, weights, and shapes; and spend a large amount of time driving as part of their work. This work involves a high level of tension and requires attention and concentration. Despite the frequency of industrial accidents in the courier industry, studies on safety and health to quantitatively analyze and systematize the work of courier workers are very scarce. Therefore, to define the work process necessary for investigating the harmful factors in delivery service and the work analysis, this study conducted interviews and on-site surveys to analyze the unit work of the delivery service by targeting delivery workers. In other words, a framework of unit work for work analysis was presented to enable research and analysis by considering the aforementioned characteristics of the courier industry. The process was broadly divided into work, transport, storage, delay, and inspection. Work was divided into loading, sorting, unloading, and door subcategories, and transportation was divided into vehicle, cart, and walking subcategories as well as 10 small processes. Moreover, 22 unit works were again drawn by conducting field surveys and interviews. The risk of unit work derived from this study was ergonomically evaluated, and the ergonomic analysis revealed that uploading and transportation were the most dangerous. The results of this study could be used as basic data for preventing industrial accidents among courier workers, whose work has increased with the logistics volume and the development of the logistics industry.

A Study on Application Design Scenarios for the Gas Safety Field Workers -focused on the pipe work- (가스 작업 안전 앱 시나리오 설계에 대한 연구 -배관 작업을 중심으로-)

  • Lee, Jooah;Kim, Mi-Hye;Kang, Bong Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.273-281
    • /
    • 2016
  • The issue about the safety management of gas related work has been studied toward a direction to utilize IoT system recently. For this purpose, the matters of user's demand has been deduced through the literature survey, field survey, and professional consultation, by studying the characteristics of worker, work, and work site. In summary, these are the demands for mobile App, 1)a clear arrangement of contents, 2)a design with high readability, 3)a design with low death, 4) securing of user's accessibility, 5)an effective information transmission plan in the work section where it is impossible to operate the mobile device, 6)an activation of alarm function at the section of high working error, 7)a fast two-way transmission and receipt of safety inspection matter needed at work, 8)a selection of images and contents that can guide the situation to the worker in case of accident, 9)an alarm function for the degree of danger in an area of worker's location. Based on these, a basic design of safety application for gas related work has been proposed, that can secure the user accessibility.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Assessment of Isokinetic Muscle Function, Balance and Flexibility in Elite High School Kayakers (고등학교 엘리트 카약 선수들의 등속성 근기능·균형성·유연성 측정 및 평가)

  • Shin, Kwang-Taek;Sohn, Jee-Hoon
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.407-416
    • /
    • 2018
  • The purpose of this study is to evaluate elite high school kayaker's iso-kinetic muscle function and provide physical training advices. Biodex system IV, Biodex stabilizer system, Inbody 3.0 and CNP-5403 are used to investigate 11 kayaker's muscle function(peak torque, average power and work fatigue), dynamic balance, body compositions, and flexibility. S4, S5, S8, S10, S11 are needed to train shoulder muscle strength and power. S5, S6, S10, S11 are needed to strengthen shoulder muscle endurance. S5, S7, S8, S10, S11 are needed to train knee muscle strength and power. S1, S4, S5, S10 are needed to strengthen knee muscle endurance. S3, S10, S11 are needed to train wrist muscle endurance. Based on these results we should establish an muscle function enhancing program with periodic inspection for elite kayakers. And standardized training program should be sublated.

The effects of combined exercise training 12weeks on body composition and basic physical strength in obese college women (12주간 복합운동이 비만 여대생의 신체조성 및 기초체력 향상에 미치는 영향)

  • Kim, Won-Hyun;Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.471-478
    • /
    • 2016
  • The purpose of this study is to analyse the effect of 12-weeks of combined training on body composition and basic physical strength of obese female college students. The research object was composed of 12 obese female college students of D University, who learned the purpose of this research enough and wrote the consent form of voluntary participation, who have no medical history and currently no special disease, and no experience in regular exercise. They underwent body composition inspection, left right grasping power which is the basic physical strength, back muscle strength, flexibility, rapidity, muscle endurance, and the researcher performed descriptive statistics to calculate the average standard deviation, and analyzed to verify difference between groups by using paired t-test. With statistical significance level p<.05, the results are as follows. Obese female college students showed meaningful differences in weight, skeletal muscles, body fat volume and left right grasping power, back muscle strength, rapidity(p<.05) - flexibility and muscle endurance(p>.05).