• 제목/요약/키워드: digital infrared thermal imaging

검색결과 127건 처리시간 0.032초

영수보사(迎隨補瀉) 침자극(鍼刺戟)이 경혈영역(經穴領域)의 온도변화(溫度變化)에 미치는 영향(影響) (The effects on the thermal changes of an acupuncture point area with the Young-Su-Bo-Sa(迎隨補瀉)-Acupuncture stimulation)

  • 이승우;이정훈;송범용;육태한
    • Journal of Acupuncture Research
    • /
    • 제18권2호
    • /
    • pp.161-174
    • /
    • 2001
  • Purpose : This study is to see the existence of the meridian and the meridian point through their response to the Young-Su-Bo-Sa. Objective and Methods : For this purpose, with acupuncture stimulation with Young-Su-Bo-Sa on the Hapkok of left hand and an the non-meridian point, and using the Digital infrared thermal image(D.I.T.I), We observed and analyzed the thermal changes of Hapkok, Samgan, non-meridian point(NA), Yonghyang, Soryo, Chonchu, Shingwol. Results and Conclusions : To sum up, We could understand Young-Su-Bo-Sa stimulation through the study findings that the acupuncture stimulation on the meridian point caused significant thermal changes of the associated meridian and meridian point, and Young-Su-Bo stimulation given in the direction of the meridian passage caused increases in the thermal changes of the associated meridian point, while Young-Su-Sa stimulation caused decreases in the thermal changes of the associated meridian point.

  • PDF

오공약침(蜈蚣藥鍼)의 항염증 효과 치험 2례 (Two Cases on Anti-inflammatory Effect of Scolopendrid Herbal-Acupuncture)

  • 원재균;이윤경;한상원;서정철
    • 대한약침학회지
    • /
    • 제7권3호
    • /
    • pp.109-114
    • /
    • 2004
  • Objective : This study was designed to investigate the anti-inflammatory effect of Scolopendrid Herbal-Acupuncture. Methods : Scolopendrid Herbal-Acupuncture was administered one time on everyday and A-shi points were selected. Except Scolopendrid Herbal-Acupuncture administration, other therapies(conventional body acupuncture, physical therapy and so on) were not performed at all. We evaluated the patient through Visual Analogue Scale(VAS) and Digital Infrared Thermal Imaging(DITI). Results : After 2 or 3 times of treatment, the patient showed that clinical symptoms and VAS were lessened and there was a change of temperature in DITI. Conclusions : According to the results, Scolopendrid Herbal-Acupuncture may have anti-inflammatory effects. But further studies are required to prove the exact effect.

소양인 처방을 활용한 수족랭증(手足冷症) 치험 2례 (Clinical Study on Two Patients Typed as Soyangin with Cold Hypersensitivity on Hands and Feet)

  • 김오영;김동훈;유수향;박수곤;이장식;박혜선
    • 동의생리병리학회지
    • /
    • 제24권6호
    • /
    • pp.1082-1086
    • /
    • 2010
  • This study reports two cases of patients with cold hypersensitivity on hands and feet who were typed as the Soyangin. Although the two patients were experiencing the same symptom of cold hypersensitivity on hands and feet, we diagnosed one as a Soyangin Kyel-Hyung syndrome(結胸證) and the other as a Mang-eum syndrome(亡陰證). So we prescribed them Medications for Soyangin. And we used D.I.T.I.(Digital Infrared Thermal Imaging) to prove the improvement for cold hypersensitivity on hands and feet. The temperature change of D.I.T.I. after treatment showed that the main symptom After treatment, their symptoms were improved and the patients' D.I.T.I results also showed their improvement.

흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향 (The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments)

  • 윤정규;이건철
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF

일개 한방병원에 내원한 갱년기 여성의 연령에 따른 적외선체열분포(DITI)와 Kupperman’s Index(KI), Menopause Rating Scale(MRS)간의 상관성 연구 (A Study on the Relationship between Digital Infrared Thermal Imaging (DITI), Kupperman’s Index (KI) and Menopause Rating Scale (MRS) of Postmenopausal Women)

  • 안뜰에봄;김동철
    • 대한한방부인과학회지
    • /
    • 제28권4호
    • /
    • pp.57-64
    • /
    • 2015
  • Objectives : To study correlation between Digital Infrared Thermal Imaging, Kupperman’s Index (KI) and Menopause Rating Scale (MRS) of Postmenopausal Women Methods : We analyzed 114 patients visiting Pohang Oriental Hospital from 1 st January 2014 to 30 th September 2015. The evaluating indexed of this trial were Age, DITI, KI, MRS. Temperature and different of temperature, such as In-dang (HN3), dan-Jung (CV17), gwan-won (CV4), hyup-back (LU4), no-gung (PC8), bock-to (ST31), and tae-chung (LR3). Results : Age was no correlation with DITI, KI, and MRS. There were positive correlation with KI and MRS significantly. DITI was not correlated with Age, KI and MRS, while ⊿T1 (LU4-PC8) was correlated with ⊿T2 (ST31-LR3) and ⊿T3 (CV17-CV4). Conclusions : There were non-significant correlation between DITI and Menopausal scale, but significant correlation in DITI themselves, Menopausal themselves. The More studies ar needed for the more accurate oriental medical diagnosis

적외선체열촬영(赤外線體熱撮影)(DITI)분석(分析)을 통(通)한 요각통(腰脚痛) 환자(患者)의 임상적(臨床的) 고찰(考察) (Clinical Study on Yogaktong Patients by Analysing Digital Infrared Thermal Imaging)

  • 김동일;조명제;박쾌환
    • Journal of Acupuncture Research
    • /
    • 제17권3호
    • /
    • pp.199-207
    • /
    • 2000
  • Objectives : Yogaktong is the general term of lowback and sciatic pain. Simplely this is not for the syndrom or illiness but for the symptoms. In the field of western medicine, it's difficult to find out the cause and to be objective when the patient feel back and sciatic pain without HNP of L-spine. Methods : To get objective yogaktomg symptoms I did this study. This is the case study of 103 patients who felt yogaktomg, and had taken DITII(Digital Infrared Thermal Imaging) at department of acupuncture and moxibustion in Conmaul Oriental medical hospital from september 1, 1998 to august 30, 1999. Results : The temperature raised 53.4% at center of lowback. There is a temperature differance on both legs, in 70.73% of patients the pain side of leg is lower temperature than the other side. Conclusions : Generally, DITI of patients who have lowback and sciatic pain is shown increasing temperature in center of lowback, decreasing temperature in pain side of leg.

  • PDF

향사이중탕가미방(香砂理中湯加味方)으로 전신냉감과 자한 호전된 여환 1례 (A Case Report of Cold Hypersensitivity and Perspiration Treated with Hyangsayijoongtang-gamibang)

  • 최석영;이미주;김은경;이창훈;이경섭
    • 대한한방체열의학회지
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2011
  • Purpose : The purpose of this study is to investigate effect of Hyangsayijoongtang-gamibang on Cold Hypersensitivity and accompanying perspiration. Methods : Hyangsayijoongtang-gamibang was used for a Cold Hypersensitivity patient with accompanying perspiration that was admitted to Kangnam Kyung-Hee Korean Hospital from May 2nd, 2011 to May 14th, 2011. The efficacy of the treatment was evaluated with Digital Infrared Thermal Imaging(DITI). along with objective and subjective observations. Results : After treatments of oriental medicine. the mean body temperature elevated $1.32^{\circ}C$. and the mean temperature difference between different points of the body decreased more than 50%. Subjective observation of Cold Hypersensitivity and accompanying perspiration using Visual Analog Scale(VAS) also showed improvement. Conclusion : Results suggest that Hyangsayijoongtang-gamibang is effective in treating Cold Hypersensitivity patients with accompanying perspiration.

  • PDF

압박손상으로 발생한 비골신경마비 환자 치험 1례 (A Clinical study on Sitting Cross-Legged Patient Diagnosed as Peroneal Neuropathy)

  • 김정아;지민정;원제훈;안뜰에봄;김동철
    • 척추신경추나의학회지
    • /
    • 제9권1호
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: The Purpose of this study is to report the effects of Korean medical treatment on patient of peroneal neuropathy caused by sitting cross-legged. Methods: The patient diagnosed as peroneal neuropathy was treated by Acupuncture, Bee Venom therapy, Herbal medicine. To evaluate the effects of Korean treatment, we used Range of Motion(ROM) of Ankle, Visual Analog Scale(VAS), Numeric Rating Scale(NRS), Ankle-Hind-foot Scale(AHS), Digital Infrared Thermal Imaging(DITI). Results: After treatment, ROM of Ankle, VAS, NRS, AHS were improved. Temperature Difference(${\Delta}T$) was decreased on DITI. Conclusions: This study suggests that Korean medical treatment might be effective on sitting cross-legged patient diagnosed as Peroneal Neuropathy.

  • PDF

열상장비의 실시간 영상 신호처리 (Real Time Image Processing of Thermal Imaging System)

  • 홍석민;유위경;윤은숙
    • 한국군사과학기술학회지
    • /
    • 제7권4호
    • /
    • pp.79-86
    • /
    • 2004
  • This paper has presented to the design results of the analog and digital signal processor for the 2nd generation thermal imaging system using $480\times6$ infrared focal plane array In order to correct non-uniformities of detector arrays, we have developed the 2-point correction method using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we developed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained a high qualify thermal image and acquired good result.

구안와사환자에서 D.I.T.I.의 진단적 가치에 대한 임상고찰 (The Clinical Observation of Diagnostic value in Bell's palsy with Digital infrared Thermal Imaging)

  • 오상덕;임승만;백은탄;김영태;홍세영;라수연;신현수
    • 대한한방내과학회지
    • /
    • 제22권4호
    • /
    • pp.573-578
    • /
    • 2001
  • Objective: This study was carried out to investigate the correlation between prognosis and differential temperature of Digital infrared Thermographic Imaging in Bell's palsy. Methods: The clinical data and thermographic images were analyzed on 50 cases of Bell's palsy who were treated ambulatory in Dong-so oriental hospital from October 2000 to May 2001 And 32case were selected who underwent thermographic imaging within 7days of onset. Results: There was no statistic significance between ${\Delta}T$ and the length of treatment, but the length of treatment tends to grow as ${\Delta}T$ increased. The length of treatment was shortest in normal thermal pattern, followed by hyperthermal and hypothermal. Conclusions: According to the results, there was a tendency that ${\Delta}T$ value is proportional to treatment days, although it is not significant statistically.

  • PDF