DMIDR 장치의 재구성 알고리즘 별 성능 평가 (Performance Evaluation of Reconstruction Algorithms for DMIDR)

  • 곽인석;이혁;문승철
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.29-37
    • /
    • 2019
  • DMIDR (General Electric Healthcare, USA)은 GE 사(社)의 최신 장비로써 PSF (Point Spread Function reconstruction), TOF(Time of Flight)와 Q.Clear의 적용이 가능하다. 특히, Q.Clear는 보정 알고리즘으로써 복셀(voxel)단위 신호 잡음 제거로 기존 OSEM (Ordered Subset Expectation Maximization)의 한계를 넘어설 수 있다. 따라서 이러한 재구성 및 보정 알고리즘의 성능 평가를 통해 정확한 SUV를 구현하며, 병변 검출 능력에 도움이 되는 알고리즘의 조합을 확인하고자 하였다. H/B(Hot & Background) Ratio 2:1, 4:1, 8:1의 비율로 NEMA/IEC 2008 PET phantom을 제작하였다. DMIDR의 NEMA test protocol을 이용하여 영상 획득을 하였다. 재구성 조합은 (1) VPFX(VUE point FX(TOF)), (2) VPHD-S(VUE point HD+PSF), (3) VPFX-S(TOF+PSF), (4) QCHD-S-400(VUE point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5) QCFX-S-400(TOF+Q.Clear(${\beta}-strength$ 400)+PSF), (6) QCHD-S-50(VUE point HD+Q.Clear(${\beta}-strength$ 50)+PSF), (7) QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50) + PSF)의 7 가지로 구성하였다. H/B Ratio 및 재구성 알고리즘 별로 측정된 결과를 이용하여 CR (Contrast Recovery)와 BV (Background Variability)을 구하였다. 또한, 각 조합의 count를 측정하여 SNR (Signal to Noise Ratio)과 RC(Recovery Coefficient)를 구하고 SUV (Standardized Uptake Value)를 측정하였다. 구의 크기가 가장 작은 10 mm와 13 mm에서는 VPFX-S, 17 mm 이상에서는 QCFX-S-50에서 가장 높은 CR 결과를 보였다. BV와 SNR의 비교에서는 QCFX-S-400과 QCHD-S-400에서 좋은 값을 보였다. SUV 측정 결과는 H/B ratio와 비례하여 증감하는 양상을 보였다. SUV에 대한 RC의 경우 H/B ratio와 반비례하는 양상을 보였으며, 재구성 알고리즘 중에서는 QCFX-S-50이 가장 높은 값을 보였다. 또한, Q.Clear에 ${\beta}-strength$ 400이 적용된 재구성 알고리즘들이 낮은 값 분포를 보였다. Q.Clear가 적용된 재구성 조합은 ${\beta}-strength$를 높이면 신호잡음이 억제되어 영상 품질면에서 우수한 결과를 보였고 ${\beta}-strength$를 낮추면 선예도가 증가하며, partial volume effect가 감소하여 기존의 재구성 조건에 비하여 높은 RC에 근거한 SUV 측정이 가능하였다. 이러한 진보된 알고리즘의 사용으로 보다 정확한 정량화와 미세병변 검출능력을 향상 시킬 수 있으나 상관 관계를 고려하여 목적에 맞는 최적화 과정이 필요할 것으로 사료된다.

간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가 (Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System)

  • 공창기;최남길;정묘영;송종남;김욱;한재복
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.27-35
    • /
    • 2017
  • 본 연구의 목적은 DR (digital radiography) 장비에서 팬텀을 이용하여 간접변환방식의 CsI:Tl 검출기와 $Gd_2O_2S$ 검출기를 중심으로 두께가 두꺼운 흉부 팬텀과 중간 두께의 대퇴부 팬텀, 그리고 피사체의 두께가 얇은 손 팬텀의 영상을 획득하고 SNR과 CNR을 분석하여 검출기의 특성을 알아보고자 하였다. 피사체 두께 변화에 따른 SNR과 CNR을 측정한 결과 중간 두께의 대퇴부 팬텀과 두께가 얇은 손 팬텀을 촬영 하였을 때 SNR과 CNR은 $Gd_2O_2S$ 검출기보다 CsI:Tl 검출기에서 높게 나타났음을 확인 할 수 있었다. 그러나 두께가 두꺼운 흉부 팬텀을 사용하였을 때는 $Gd_2O_2S$ 검출기의 SNR이 80~125 kVp 일 때와 CNR이 80~110 kVp 일 때 CsI:Tl 검출기 보다 값이 높게 나타났고, 저관전압에서 고관전압으로 갈수록 SNR과 CNR은 모두 증가하였다. 중간 두께의 대퇴부 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 40~50 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었고, $Gd_2O_2S$ 검출기의 SNR과 CNR은 40~60 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었다. 두께가 얇은 손 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 저관전압에서 감소하다가 고관전압으로 갈수록 증가하면서 100~110 kVp에서는 감소하였고, $Gd_2O_2S$ 검출기의 SNR과 CNR은 고관전압으로 갈수록 감소하는 것을 확인하였다. MTF는 0.5~3 lp/mm에서 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 6.02~90.90%로 높음 보여주고 있고, DQE는 0.5~3 lp/mm에서 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 66.67~233.33% 높음 보여주고 있다. 결론적으로 MTF와 DQE의 비교에서는 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 높게 나타났지만, 두꺼운 흉부팬텀에서 일정 관전압 구간에서는 저가의 $Gd_2O_2S$ 검출기가 고가의 CsI:Tl 검출기보다 SNR과 CNR이 높다는 것을 확인하였다. 흉부 X선 검사 시 CsI:Tl 검출기보다 $Gd_2O_2S$ 검출기를 사용하여 우수한 화질의 흉부영상을 구현함으로써 검사에 유용할 것으로 판단되어지며, 사용자 입장에서 검출기 형태를 결정 할 때 가격대비 성능을 고려 해볼 사항으로 판단된다.

강제동원 구술자료의 관리와 활용 -일제강점하강제동원피해진상규명위원회 소장 구술자료를 중심으로- (Management and Use of Oral History Archives on Forced Mobilization -Centering on oral history archives collected by the Truth Commission on Forced Mobilization under the Japanese Imperialism Republic of Korea-)

  • 권미현
    • 기록학연구
    • /
    • 제16호
    • /
    • pp.303-339
    • /
    • 2007
  • '일제강점하 강제동원 피해'라 함은 만주사변 이후 태평양전쟁에 이르는 시기에 일제에 의하여 강제동원 되어 군인 군속 노무자 위안부 등의 생활을 강요당한 자가 입은 생명 신체 재산 등의 피해를 말한다. 강제동원 피해 역사를 복원하기 위한 노력이 피해당사자, 유족, 시민단체, 학계 등에서 이루어져왔고, 그 결과 2004년 3일 5일 ${\ll}$일제강점하 강제동원피해 진상규명등에 관한 특별법${\gg}$ (2007년 5월 17일 일부 개정)이 제정 공포되었다. 이를 근거로 2004년 11월 10일 국무총리 소속으로 일제강점하 강제동원피해진상규명위원회(이하 강제동원위원회)가 발족하였고, 2005년 2월 1일부터 일제강점하 강제동원 피해의 진상을 규명하여 역사적 진실을 밝히는 것을 목적으로 업무를 수행하고 있다. 주요 업무는 강제동원 피해신고접수 및 피해신고조사(피해자 및 유족 심사 결정), 진상조사신청접수 및 진상조사, 진상조사 및 피해판정 불능에 관한 사항, 피해판정에 따른 호적정정, 강제동원 관련 국내외 자료수집 분석 및 보고서 작성, 유해발굴 및 수습 봉환, 사료관 및 추도공간 조성사업 등이다. 강제동원위원회는 피해조사 및 진상조사 업무를 위해 다양한 기록을 발굴 수집해 오고 있다. 여타 피해의 역사가 그러하듯이 이미 공개되었거나 새롭게 발굴되는 기록은 강제동원의 다양한 역사상을 확인하기 어려울 만큼 그 양이나 질에 면에서 부족하다. 피해의 역사에서 피해당사자의 이야기는 기록의 부재를 메우기도 하고, 기록 이상의 근거적 가치를 갖기도 한다. 강제동원위원회는 피해생존자와의 구술면담을 통해 다수의 구술자료를 생산하였고 조사업무에 활용하며 체계적인 관리방법을 토대로 관리하고 대중적인 활용까지 꾀하고 있다. 강제동원위원회의 구술자료는 생산 당시부터 철저한 기획에 의해 이루어졌고, 생산단계부터 관리와 활용의 편의성을 염두에 두고 디지털매체의 생산을 유도했다. 또한 조사업무 과정에서 생산되는 구술자료의 한계를 극복하기 위해 수차례 면담자 교육을 실시하고, 면담자로 하여금 구술당시의 상황을 면담일지로 남기도록 했다. 강제동원위원회는 소장 기록을 관리하는 별도의 기록관리시스템을 갖고 있지 않다. 디지털 아카이브는 피해 진상 관리시스템과 전자결재시스템을 통해 생산되어 관리되지 않는 생산 수집 기증 기록을 등록 검색하는 역할을 한다. 구술자료는 디지털 아카이브에 등록이 되어, 실물과 중복 보존되고 있다. 구술자료는 등록과 동시에 분류, 기술행위가 이루어지고 구술자료의 관리 아이디인 등록번호, 분류번호, 비치번호 등을 부여받게 된다. 강제동원위원회는 구술자료의 적극적인 활용을 위하여 구술기록집의 발간을 지속적으로 해오고 있고, 영상물 등의 제작을 계획하고 있다. 강제동원위원회의 구술자료는 정부차원의 조사 업무 과정에서 생산된 것이라는 한계, 예산부족이나 기록관리시스템 등의 부재 등을 넘어서 한시조직으로서 가능한 적극적인 방법으로 생산 관리 활용되고 있다. 축적된 구술자료는 향후 특별법에 규정되어 있는 대로 사료관 등이 건립된다면 대중 이용자들을 위해 더 체계적으로 관리 활용될 것이다.

개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구 (Development of Standard Process for Private Information Protection of Medical Imaging Issuance)

  • 박범진;유병규;이종석;정재호;손기경;강희두
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.335-341
    • /
    • 2009
  • 목 적 : 기존 필름으로 발급되었던 의료영상은 IT기술의 발달로 디지털화 되어 CD로 발급되고 있다. 그러나 발급 시 신분확인을 하고 있는 의무기록과는 달리 필름을 사용하던 시절부터 의료영상은 별다른 신분확인을 하지 않는 의료기관이 많다. 이에 신청자의 개인의료정보 보호에 대한 인식 실태를 조사하고 여러 의료기관의 CD 또는 DVD 등의 매체를 통한 의료영상 복사 현황을 조사, 정보보안에 관련된 국, 내외 법률 및 권고안을 분석하여 국내 환경에 부합하는 의료영상 복사 발급과 절차를 마련하는 기준을 제시하고자 한다. 대상 및 방법 : 첫째, 2008년 5월 1일부터 7월 31일까지 수도권에 있는 33개 종합병원을 대상으로 의료영상복사 신청 시 구비서류, 발급절차 등을 전화를 통한 유선 조사를 시행하였다. 신청자에 따른 구비서류를 의료법 제 21조 2항에 의거 (1) 본인일 경우 신분증 확인, (2) 가족일 경우 신청자 신분증, 가족관계 서류(건강보험증, 가족관계증명서, 등본 등), (3) 제 3자 대리인일 경우 신분증, 위임장, 인감증명서로 기준을 마련하여 조사하였다. 둘째, 연구기간 동안 위의 기준에 따라 의료영상을 발급해 주고 있는 K 의료원에 복사를 신청하는 신청자들이 준비해온 구비서류 여부를 파악하였다. 셋째, 구비서류의 확인 및 미비 시 조치 등에 대한 발급절차의 기준을 정립하여 프로세스를 개발하였다. 결 과 : 수도권 33개 의료영상 발급현황을 조사한 결과 모든 조건을 충족한 병원은 16곳(49%), 신분증만 있으면 가능한 병원은 4곳(12%), 누구나 신청 가능한 병원 4곳(12%)이었으며 의료영상을 발급하는 부서가 아닌 진료과에서 신청하는 곳이 9곳(27%)으로 구비서류 조건여부는 알 수 없었다. 또한 신청자들이 복사 신청시 준비해온 구비서류가 조건에 충족한지 3개월간의 조사 결과 모두 준비한 경우(완비)는 629건(49%), 일부만 준비한 경우(일부 미비) 416건(33%), 모두 준비하지 않은 경우(미비) 226건(18%)이였다. 위의 연구결과를 근거로 의료영상 복사 신청 절차에 대한 프로세스를 정립하여 객관적인 응대를 할 수 있도록 하고, 환자와의 마찰을 줄이고 불편을 최소화 하면서 환자의 편의를 도모하고자 세분화된 발급절차 모형도를 작성하였다. 결 론 : 다른 전산 시스템과 달리 의료영상 시스템인 PACS가 의료기기로 분류되어 있는 것은 그만큼 의료정보의 중요성이 크다는 의미이다. 또한 의료영상의 학문적 성격으로 의학교육 및 연구에 많이 쓰이는데 이러한 이유로 쉽게 인용되고 남용 될 수 있다. 따라서 의료영상은 전문적인 교육을 받은 의료영상 관리자에 의해 적절한 발급 기준으로 발급, 관리되어야 할 것이며 이에 관한 개인정보보호와 의료영상에 대한 적극적인 홍보가 필요할 것이다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

전부 피개관의 치아 형성 시 축면 경사각에 대한 조사 (Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns)

  • 김성진;배아란;우이형;김형섭
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.21-32
    • /
    • 2010
  • 삭제된 치아의 경사도는 치관 수복물의 유지와 저항에 있어 매우 중요한 요소이다. 하지만 다양한 구강 내 환경과 술자의 능력에 따라 이상적인 경사도를 얻는 것은 쉽지 않다. 따라서 이상적으로 삭제된 치아의 경사도와 실제 임상에서 삭제된 치아의 경사도를 조사하고자 한다. 본 실험의 연구 자료는 K대학 부속 치과병원 중앙 기공실을 통하여 보철과 전공의가 시술한 환자의 모형과 일반 기공소를 통해 일반 개업의가 시술한 환자의 모형을 수집한다. 연구 방법은 각 치아의 근원심면과 협설면을 디지털 카메라를 통해 촬영한 뒤 'ImageJ' 프로그램 상에서 치아의 삭제 각도를 측정 한 뒤 항목별( 1. 술자 집단별 분류, 2. 치열궁 내에서의 위치에 따른 분류, 3. 삭제 양식에 따른 분류 )로 분류하여 비교 분석한다. 이번 연구를 통해 조사한 결과 국내 임상가의 지대치 형성시 축면 경사각의 평균은 $15.02^{\circ}$ 표준 편차는 ${\pm}10.13^{\circ}$였다. 1. 술자 집단별 분류에 대한 분석 일반 치과의 집단의 측면 경사각과 보철과 전공의 집단의 축면 경사각에서 유의성 있는 차이를 보였다(p<0.05). 2. 치열궁 내에서의 위치에 따른 분석 치아의 근원심면과 협설측면에 따라 일반 치과의 집단의 경우 유의성 있는 차이가 없었으며(p>0.05) 보철과 전공의 집단에서는 유의성 있는 차이를 보였다(p<0.05). 치아의 전후적인 위치에 따라 일반 치과의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며 (p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며(p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 상악과 하악으로 분류하여 분석한 경우 일반 치과의 집단에서 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단에서도 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 악궁을 좌측과 우측으로 분류하여 분석한 경우 일반 치과의 집단과 보철과 전공의 집단에서 각각 유의성 있는 차이가 없었다(p>0.05). 3. 삭제 양식에 따른 분석 단일 치관을 위한 지대치와 3본 고정성 부분 의치를 위한 지대치로 분류하여 분석한 결과 일반 치과의 집단에서 근원심면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이를 보였으며(p<0.05) 협설측면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이가 없었다(p>0.05). 보철과 전공의 집단에서는 협설측면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이가 없었으며(p>0.05) 근원심면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이를 보였다(p<0.05). 이상에서 임상에서 치아 삭제시 이상적인 축면 경사각을 얻기 힘들며 이는 술자의 경험과 악궁 내에서의 위치, 삭제 양식에 따라 영향을 받을 수 있다.

햄릿 공연을 위한 무대의상 디자인 (II) - 패턴 및 실물제작 - (Stage Costume Design for Performance Hamlet (II) - The Study on Pattern and Manufactured Product -)

  • 김순구;황성원
    • 한국의류산업학회지
    • /
    • 제6권1호
    • /
    • pp.41-50
    • /
    • 2004
  • This research proposes the on-stage costumes for the play Hamlet of Shakespeare performed by Yunheedan Guhri Pae - the Street Theater Troupe. Stage costumes have an important role in displaying the characteristics of each characters to the audience and has big visual effects. However, in order to design the costumes in the object viewpoints of the audience, the survey on the images of the characters who had actually watched the performance was taken place and proposed the costume design according to the results of the survey. Hamlet a: This result was applied to propose a sweater in black color, black leather pants and vest. Hamlet b: This result was applied to propose hooded coat in purple in middle level of brightness and color spectrum and yellow coat. For free image, loose pants in blue and vest in the same color tone were proposed. Gertrude a: This result was applied to use purple (violet) with reddish tone to propose the formation of a dress applying tailored suit. Gertrude b: This result was applied to propose purple gown and the one-piece dress with black laces. Ophelia a: This result was applied to propose feminine white dress and cape in purple color tone. Ophelia b: This result was applied to propose dyed and weaved clothes. Through the surveys as above, the images of each character was driven in adjectives, and using the results driven from the brightness, coloration, and color, color images were proposed. Only one costume cannot make up for the stage costumes and because it exists as an element of stage production, it is true that costumes are limited in some areas. However, that limit can become the motive of the costume. There is a limit, which the designer cannot produce the costumes as he or she had designed but I believe it is the center of the on-stage customers to display the characteristics of the characters according to the given concept. The limit of this research is the fact that because the costumes were designed so they fit the conditions already given, thus it was difficult to regard the process of designing and producing the costume as a project done according to the interaction. And in the future, if it is possible, I wish for the joint research with the people responsible for stage art to take place as a practical stage art. It was possible to produce practical costume since they were produced for actual performance and the production of costumes considering the dance steps, line of flow, and acting, was able to reduce the trial and error on stage. Through this research, I felt that the understanding and smooth interaction on diverse other areas not limited to the costume design should be taken place and believe that this was a research that proposes new research method since there had been only a few previous research regarding the on-stage costumes for actual performances. Therefore, this research had depended on the surveys given to the audiences to endow objectivity, however, I wish this research can contribute to defining effective process and methods for the on-stage costumes with more active researches with diverse methods and in diverse areas. I am sorry that the costume production for all the characters and all the scenes in Hamlet couldn't be done due to many limitations. As the following research assignment, I am planning on designing the costumes for all the scenes.

초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계 (Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1)

  • 김세진;고정휘;임현선
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.409-415
    • /
    • 2011
  • 목적: 초점거리의 비가 3:1인 아나모픽 렌즈를 적용하여 탐지거리를 증대시키는 열상 광학계를 설계하였다. 방법: 화각이 $50^{\circ}{\sim}60^{\circ}$, 초점거리는 수평방향 36 mm, 수직방향 12 mm로 구속조건을 정하였다. 구속조건으로 f-number는 4, 화소 크기는 $15{\mu}m{\times}15{\mu}m$, 한계 분해능은 33l p/mm에서 25% 이상으로 제한하였다. 재질은 Si, ZnS, ZnSe를 사용하였으며 파장영역은 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$로 설정하였다. 설계한 열상 카메라의 광학적 성능 및 탐지거리와 나르시서스, 비열화를 분석하였다. 결과: 열상 광학계의 초점거리는 Y축 방향이 12 mm, X축 방향이 36 mm를 만족하였으며 f-number는 4를 만족하였다. 전장의 길이는 76 mm로 시스템의 전반적인 부피를 감소시켰다. 구면수차와 비점수차는 ${\pm}$0.10내로 2 pixel 크기보다 작게 나타났다. 왜곡수차는 10%이내로써 열상 카메라로 사용하는데 문제가 없음을 확인하였다. 광학계 MTF 성능은 33l p/mm에서 full field 까지 25%이상으로 구속조건을 만족하였다. 설계된 열상 광학계는 2.9 km까지 탐지할 수 있으며 4면을 제외한 나머지 면들의 나르시서스 값을 줄여 상 번짐이 감소하였다. 민감도 분석을 통해 5번째 렌즈를 보상자로 선택하여 온도 변화에 따른 MTF 해상력을 높였다. 결론: 아나모픽 렌즈를 적용해서 설계한 열상 광학계의 광학적 성능은 구속조건을 만족하였으며 더 긴 탐지거리와 나르시서스의 감소, 온도에 따른 해상력이 증가됨을 확인하였다.

편측 요통을 호소하는 환자에 있어서 척추 주위 근육의 지방량과 통증과의 관계 (Relationship between Low Back Pain and Lumbar Paraspinal Muscles Fat Change in MRI)

  • 김하늘;김경훈;김주원;진은석;하인혁;고동현;홍순성;권혁준
    • 한방재활의학과학회지
    • /
    • 제19권1호
    • /
    • pp.135-143
    • /
    • 2009
  • 목적 : 요통은 임상에서 가장 흔하게 접할 수 있는 질환이며, 동시에 통증으로 인한 근무 결손도나 생활 불편감이 높은 질병이다. 그래서, 많은 연구들이 요통을 일으키는 원인 혹은 악화시키는 유발 인자를 밝혀내려는데 초점이 맞추어져 있다. 이번 연구의 목적은 편측 요통을 호소하는 환자에 있어서 MRI에서 조사된 척추 주위 근육의 지방량과 통증과의 관계에 대해서 알아보는데 있다. 방법 : 2007년 11월부터 2008년 4월까지 본원에 요통으로 내원한 환자를 대상으로, 편측 요통을 호소하며, 체질량 지수가 $25kg/m^2$ 이하이며, 만 20세이상 40세미만인 환자 24명을 대상으로 연구를 진행하였다. MRI에서 조사되어진 L4-5 디스크 레벨의 척추 주위 근육의 지방량을 객관적인 pseudocoloring technique을 이용해 측정하고, paired t-test로 결과를 분석하여 요통이 유발된 측과 지방량의 관계에 대해서 연구하였다. 결과 : 요통이 있는 측의 지방량과 요통이 없는 측의 지방량을 측정하여 데이터를 분석하였다. 양측의 지방량과 통증의 유무에 대한 관계는 통계적으로 유의한 수치를 나타냈다(P <0.05). 요통이 있는 측과 없는 측과의 성별, 나이, BMI의 통계적인 차이는 없었으며, 지방량 측정시 남자들이 여자들에 비해 지방량이 더 높게 측정되었다(남자 $8.5{\pm}5.1%$, 여자 $6.5{\pm}3.6%$). 결론 : 이 연구를 통해 척추 주위 근육의 지방량과 요통에 대한 상관성의 증거를 제시하였다. 잘 선별되어진 환자의 MRI를 통해 객관적인 방법으로 지방량을 체크를 하였으며, 추후 더 많은 개체수를 이용해 보다 더 정확한 관련성을 파악하고, 나아가 지방량에 따른 통증 강도의 상관성에 대해서 연구가 필요하리라 생각된다.