• Title/Summary/Keyword: digital fabrication

Search Result 366, Processing Time 0.023 seconds

Development of a Digital Soil Tensiometer using Porous Ceramic Cups (다공 세라믹 컵을 이용한 디지털 토양수분 장력계 개발)

  • Jung, In-Kyu;Chang, Young-Chang;Kim, Ki-Bok;Kim, Yong-Il;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.448-454
    • /
    • 2007
  • This study was conducted to develop a 100 kPa soil tensiometer mainly consisted of a porous ceramic cup, water-holding tube, and a digital vacuum gauge, through theoretical design analysis and experimental performance evaluation. Major findings were as follows. 1. Theoretical analysis showed that air entry value of a porous media decreased as the maximum effective size of the pore increased, and the maximum diameter of the pores was $2.9\;{\mu}m$ for measuring up a 100 kPa of soil-water tension. 2. Property analysis of tensiometer porous cups supplied in Korean domestic market indicated that main components were $SiO_2$ and $Al_2O_3$ with a porosity range of $33.8{\sim}49.3%$. 3. The porous cup selected through sample fabrication and air-permeability tests showed weight ratios of 87% and 11% for $Al_2O_3$ and $SiO_2$. The analysis of SEM (scanning electron microscope) images showed that the sample was sintered at temperatures of about $1150^{\circ}C$, which consisted of pores with sizes of up to 25% of those for commercial porous cups. 4. The prototype soil tensiometer was fabricated using the developed porous cup and a digital vacuum gauge that could measure water tension with a pressure of 85 kPa in air tests. 5. In-soil tests of the prototype conducted during a period of 25-day drying showed that soil-water tension values measured with the prototype and commercial units were not significantly different, and soil-water characteristic curves could be established for different soils, confirming accuracy and stability of the prototype.

A Study on the Development of Magnetic Levitation Experiment Kits (자기 부상 실습 장치의 개발에 관한 연구)

  • Lee Jeong-Woo;Cheong Yeon-Doo;Han Myoung-Keun
    • Journal of Engineering Education Research
    • /
    • v.8 no.1
    • /
    • pp.5-19
    • /
    • 2005
  • This paper describes the design and fabrication of magnetic levitation kits for use in the hands on experiments of automatic control, digital control and microprocessor applications in the division of mechatronics in Samcheok university. The kits are developed inspired by MIT's design, but it is designed on the digital basis, whereas MIT's is designed on the analog basis. As a result, the kits can be monitored and controlled on the analog and digital control techniques. Furthermore, the cost of kit components is comparable or lower to that of MIT design. And the kits can be controlled with magnetic hall sensors and/or infrared sensors, which provides more versatile experience on the use of sensors and signal filtering to the students. The design is fabricated and tested by authors and will be provided to the students as lab projects. The kits will be intentionally presented with a device that is poorly instrumented and poorly compensated. And the students are expected to analyze sensor signal and controller performance, and then, perform compensator design and signal filtering.

All-on-4 implant restoration with full-digital system preserving existing occlusion: A case report (완전 디지털 시스템으로 기존 교합을 보전한 All-on-4 임플란트 수복증례)

  • Kim, Kyoung Hee;Jeong, Seung-Mi;Lee, Ye Chan;An, Xue Yin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.330-337
    • /
    • 2018
  • In edentulous patients, implant - supported fixed prosthesis treatment has been proved to be useful, but involves complex treatment process. On the other hand, in the modern dentistry, digital technology has been developed day by day and it has expanded its range to the implant restoration of edentulous patients. In this case, a digital system was used for all stages of diagnosis, surgery, design and fabrication of provisional implants fixed prosthesis restoration in 66-year-old mandibular edentulous patients. In the preoperative diagnosis stage, a provisional restoration was designed based on the mucosal scan using the intraoral scanner and the stable occlusion of prefabricated complete denture of the patient. After flapless implant surgery using the surgical guide, the prefabricated interim restoration was connected to the implant and used as immediate provisional restoration. The final restoration was designed and fabricated by transferring the vertical dimension and the centric relation of the provisional restoration with stable occlusion using digital technology. We report a simple protocol of implant treatment in edentulous patients by using digital techniques to preserve the patient's vertical dimension and occlusion.

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

From TMJ to 3D Digital Smile Design with Virtual Patient Dataset for diagnosis and treatment planning (가상환자 데이터세트를 기반으로 악관절과 심미를 고려한 진단 및 치료계획 수립)

  • Lee, Soo Young;Kang, Dong Huy;Lee, Doyun;Kim, Heechul
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.71-90
    • /
    • 2021
  • The virtual patient dataset is a collection of diagnostic data from various sources acquired from a single patient into a coordinate system of three-dimensional visualization. Virtual patient dataset makes it possible to establish a treatment plan, simulate various treatment procedures, and create a treatment planning delivery device. Clinicians can design and simulate a patient's smile on the virtual patient dataset and select the optimal result from the diagnostic process. The selected treatment plan can be delivered identically to the patient using manufacturing techniques such as 3D printing, milling, and injection molding. The delivery of this treatment plan can be linked to the final prosthesis through mockup confirmation through provisional restoration fabrication and delivery in the patient's mouth. In this way, if the diagnostic data superimposition and processing accuracy during the manufacturing process are guaranteed, 3D digital smile design simulated in 3D visualization can be accurately delivered to the real patient. As a clinical application method of the virtual patient dataset, we suggest a decision-making method that can exclude occlusal adjustment treatment from the treatment plan through the digital occlusal pressure analysis. A comparative analysis of whole-body scans before and after temporomandibular joint treatment was suggested for adolescent idiopathic scoliosis patients with temporomandibular joint disease. Occlusal plane and smile aesthetic analysis based on the virtual patient dataset was presented when treating patients with complete dentures.

Protein Microarrays and Their Applications

  • Lee, Bum-Hwan;Teruyuki Nagamune
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.69-75
    • /
    • 2004
  • In recent years, the importance of proteomic works, such as protein expression, detection and identification, has grown in the fields of proteomic and diagnostic research. This is because complete genome sequences of humans, and other organisms, progress as cellular processing and controlling are performed by proteins as well as DNA or RNA. However, conventional I protein analyses are time-consuming; therefore, high throughput protein analysis methods, which allow fast, direct and quantitative detection, are needed. These are so-called protein microarrays or protein chips, which have been developed to fulfill the need for high-throughput protein analyses. Although protein arrays are still in their infancy, technical development in immobilizing proteins in their native conformation on arrays, and the development of more sensitive detection methods, will facilitate the rapid deployment of protein arrays as high-throughput protein assay tools in proteomics and diagnostics. This review summarizes the basic technologies that are needed in the fabrication of protein arrays and their recent applications.

A Programmable Compensation Circuit for System-on-Chip Application

  • Choi, Woo-Chang;Ryu, Jee-Youl
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.198-206
    • /
    • 2011
  • This paper presents a new programmable compensation circuit (PCC) for a System-on-Chip (SoC). The PCC is integrated with $0.18-{\mu}m$ BiCMOS SiGe technology. It consists of RF Design-for-Testability (DFT) circuit, Resistor Array Bank (RAB) and digital signal processor (DSP). To verify performance of the PCC we built a 5-GHz low noise amplifier (LNA) with an on-chip RAB using the same technology. Proposed circuit helps it to provide DC output voltages, hence, making the RF system chain automatic. It automatically adjusts performance of an LNA with the processor in the SoC when it goes out of the normal range of operation. The PCC also compensates abnormal operation due to the unusual PVT (Process, Voltage and Thermal) variations in RF circuits.

A study on the visual rhythm of Korean film trailer (한국영화 예고편의 시각적 리듬 연구)

  • Kim, Hwangjae;Shin, Sangki
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1472-1479
    • /
    • 2017
  • The trailer is an advertising process that requires systematic fabrication in the planning process. However, the role of sufficient consideration of the specialty of the merchandise, and the study of the quality of the merchandise, can serve as an effective advertisement. Therefore, a trailer from a marketing standpoint should effectively express the components that need to be delivered to potential audiences within a brief running time. Want to see if the rhythm of the trailers can be tangible, and how it affects receivers.

Fabrication of Inkjet Printed Strain Gauge Using PEDOT:PSS (PEDOT:PSS기반 잉크젯 프린팅 스트레인 게이지의 제작)

  • Kye, Ji Won;Han, Dong Cheul;Shin, Han Jae;Yeom, Se-hyuk;Lee, Wanghoon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.56-59
    • /
    • 2017
  • This paper presents the Inkjet-printed strain gauge using PEDOT:PSS. The strain gauge (width 0.6 mm, length 20 mm, thickness $0.3{\mu}m$) was printed on the PET film using PEDOT:PSS ink. The resistance variation of the fabricated strain gauge was measured by the digital multi-meter with the displacement range of -4 to 10 mm. As the measured result, resistance variation (${\Delta}R/R_0$) has approximately 0.75%, linearity of 99.87%. The fabricated strain gauge is expected to the various applications such as tape type pressure sensor, PMS(pressure mapping sensor), wearable devices.