• Title/Summary/Keyword: digital engineering model

Search Result 1,932, Processing Time 0.032 seconds

An evaluation of validity of three dimensional digital model fabricated by dental scannable stone (치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가)

  • Kim, Ki-Baek;Kim, Su-Jin;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

GENERATION OF GEO-SPATIAL INFORMATION USING KOMPSAT-2 IMAGERY

  • Lee, Hyun-Jik;Ru, Ji-Ho;Yu, Young-Geol;Lee, Kyu-Man
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.14-17
    • /
    • 2008
  • KOMPSAT-2 is the seventh high-resolution satellite in the world that provides both 1m panchromatic images and 4m multispectral images of the GSD. It is expected to be used across many different fields including digital mapping, territorial and environmental monitoring. However, due to the complexity and security concern involved with the use of the MSC, the use of KOMPSAT-2 images are limited in terms of geometric data, such as satellite orbits and detailed mapping information. This study aims to generate the DEM and orthoimage by using the stereo images of KOMPSAT-2 and to explore the applicability of geo-spatial information with KOMPSAT-2. In order to ensure generation of DEMs of optimal accuracy, the RPCs data and a suitable number of GCPs were used. The accuracy of DEM generated in this research compared with DEM generated from 1:5,000 digital map. The mean differences between horizontal position of the orthoimage and the digital map data are found to be ${\pm}$3.1m, which is in the range of ${\pm}$3.5m, within the permitted limit of a 1:5,000 digital map. The results suggest that DEM can be adequately used to produce digital maps under 1:5,000 scale.

  • PDF

Seismic fragility curves for a concrete bridge using structural health monitoring and digital twins

  • Rojas-Mercedes, Norberto;Erazo, Kalil;Di Sarno, Luigi
    • Earthquakes and Structures
    • /
    • v.22 no.5
    • /
    • pp.503-515
    • /
    • 2022
  • This paper presents the development of seismic fragility curves for a precast reinforced concrete bridge instrumented with a structural health monitoring (SHM) system. The bridge is located near an active seismic fault in the Dominican Republic (DR) and provides the only access to several local communities in the aftermath of a potential damaging earthquake; moreover, the sample bridge was designed with outdated building codes and uses structural detailing not adequate for structures in seismic regions. The bridge was instrumented with an SHM system to extract information about its state of structural integrity and estimate its seismic performance. The data obtained from the SHM system is integrated with structural models to develop a set of fragility curves to be used as a quantitative measure of the expected damage; the fragility curves provide an estimate of the probability that the structure will exceed different damage limit states as a function of an earthquake intensity measure. To obtain the fragility curves a digital twin of the bridge is developed combining a computational finite element model and the information extracted from the SHM system. The digital twin is used as a response prediction tool that minimizes modeling uncertainty, significantly improving the predicting capability of the model and the accuracy of the fragility curves. The digital twin was used to perform a nonlinear incremental dynamic analysis (IDA) with selected ground motions that are consistent with the seismic fault and site characteristics. The fragility curves show that for the maximum expected acceleration (with a 2% probability of exceedance in 50 years) the structure has a 62% probability of undergoing extensive damage. This is the first study presenting fragility curves for civil infrastructure in the DR and the proposed methodology can be extended to other structures to support disaster mitigation and post-disaster decision-making strategies.

Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models (치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가)

  • Lee, Gyeong-Tak;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.

Specific Absorption Rate Values of Handsets in Cheek Position at 835 MHz as a Function of Scaled Specific Anthropomorphic Mannequin Models

  • Lee, Ae-Kyoung;Choi, Hyung-Do;Choi, Jae-Ick;Pack, Jeong-Ki
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.227-230
    • /
    • 2005
  • A specific anthropomorphic mannequin (SAM) model was used to investigate the relation between local specific absorption rate (SAR) and head size. The model was scaled to 80 to 100% sized models at intervals of 5%. We assumed that the shell of the SAM model has the same properties as the head-equivalent tissue. Five handsets with a monopole antenna operating at 835 MHz were placed in the approximate cheek position against the scaled SAM models. The handsets had different antenna lengths, antenna positions, body sizes, and external materials. SAR distributions in the scaled SAM models were computed using the finite-difference time-domain method. We found that a larger head causes a distinct increase in the spatial peak 1-voxel SAR, while head size did not significantly change the peak 1-g averaged-SAR and 10-g averaged-SAR values for the same power level delivered to the antenna.

  • PDF

Application of a Grid-Based Rainfall-Runoff Model Using SRTM DEM (SRTM DEM을 이용한 격자기반 강우-유출모의)

  • Jung, In-Kyun;Park, Jong-Yoon;Park, Min-Ji;Shin, Hyung-Jin;Jeong, Hyeon-Gyo;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.157-169
    • /
    • 2010
  • In this study, the applicability of SRTM(The Shuttle Radar Topography Mission) DEM(Digital Elevation Model) which is one of the remotely sensed shuttle's radar digital elevation was tested for use as the input data in a grid-based rainfall-runoff model. The SRTM DEM and digital topographic map derived DEM(TOPO DEM) were building with 500m spatial resolution for the Chungju-Dam watershed which located in the middle east of South Korea, and stream-burning method was applied to delineate the proper flow direction for model application. Similar topographical characteristics were shown as a result of comparing elevation, flow-direction, hydrological slope, number of watershed cell, and profile between SRTM DEM and TOPO DEM. Two DEMs were tested by using a grid-based rainfall-runoff model named KIMSTORM with 6 storm events. The results also showed no significant differences in average values of relative error for both peak runoff(0.91 %) and total runoff volume(0.29 %). The results showed that the SRTM DEM has applicability like TOPO DEM for use in a grid-based rainfall-runoff modeling.

Development of Digital Twin platform using Smart Factory based CPPS (스마트팩토리 기반 CPPS를 활용한 Digital Twin 플랫폼 개발)

  • Lee, Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.305-307
    • /
    • 2021
  • In this paper, we propose a study related to the development of a Digital-Twin platform using a smart factory based CPPS (Cyber Pysical Production System) using ICT (Information Communication Technology) technology. The platform developed through this study performs a 3D model simulation function in conjunction with P3R (Product, Process, Plant, Resource) including BOP (Bill of Process) management function from the preceding manufacturing process planning stage. In addition, we propose a digital twin platform that can predict production processes, equipment, layout, and production. The platform proposed through this paper proposes a feature that can manage the entire smart factory manufacturing process from the initial planning design stage to the manufacturing, production, operation, and maintenance stages.

  • PDF

Review on Digital Image Watermarking Based on Singular Value Decomposition

  • Wang, Chengyou;Zhang, Yunpeng;Zhou, Xiao
    • Journal of Information Processing Systems
    • /
    • v.13 no.6
    • /
    • pp.1585-1601
    • /
    • 2017
  • With the rapid development of computer technologies, a number of image modification methods have emerged, which have great impacts on the security of image information. Therefore, it is necessary to protect the integrity and authenticity of digital images, and digital watermarking technique consequently becomes a research hotspot. An effort is made to survey and analyze advancements of image watermarking algorithms based on singular value decomposition (SVD) in recent years. In the first part, an overview of watermarking techniques is presented and then mathematical theory of SVD is given. Besides, SVD watermarking model, features, and evaluation indexes are demonstrated. Various SVD-based watermarking algorithms, as well as hybrid watermarking algorithms based on SVD and other transforms for copyright protection, tamper detection, location, and recovery are reviewed in the last part.

Estimation of Stand-level Above Ground Biomass in Intact Tropical Rain Forests of Brunei using Airborne LiDAR data (항공 LiDAR 자료를 이용한 브루나이 열대우림의 임분단위 지상부 생체량 추정)

  • Yoon, Mihae;Kim, Eunji;Kwak, Doo-Ahn;Lee, Woo-Kyun;Lee, Jong-Yeol;Kim, Moon-Il;Lee, Sohye;Son, Yowhan;Salim, Kamariah Abu
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • This study aims to quantify the stand-level above ground biomass in intact tropical rain forest of Brunei using airborne LiDAR data. Twenty four sub-plots with the size of 0.09ha ($30m{\times}30m$) were located in the 25ha study area along the altitudinal gradients. Field investigated data (Diameter at Breast Height (DBH) and individual tree position data) in sub-plots were used. Digital Surface Model (DSM), Digital Terrain Model (DTM) and Canopy Height Model (CHM) were constructed using airborne LiDAR data. CHM was divided into 24 sub-plots and 12 LiDAR height metrics were built. Multiple regression equation between the variables extracted from the LiDAR data and biomass calculated by using a allometric equation was derived. Stand-level biomass estimated from LiDAR data were distributed from 155.81 Mg/ha to 597.21 Mg/ha with the mean value of 366.48 Mg/ha. R-square value of the verification analysis was 0.84.

Cyber Security Risk Evaluation of a Nuclear I&C Using BN and ET

  • Shin, Jinsoo;Son, Hanseong;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.517-524
    • /
    • 2017
  • Cyber security is an important issue in the field of nuclear engineering because nuclear facilities use digital equipment and digital systems that can lead to serious hazards in the event of an accident. Regulatory agencies worldwide have announced guidelines for cyber security related to nuclear issues, including U.S. NRC Regulatory Guide 5.71. It is important to evaluate cyber security risk in accordance with these regulatory guides. In this study, we propose a cyber security risk evaluation model for nuclear instrumentation and control systems using a Bayesian network and event trees. As it is difficult to perform penetration tests on the systems, the evaluation model can inform research on cyber threats to cyber security systems for nuclear facilities through the use of prior and posterior information and backpropagation calculations. Furthermore, we suggest a methodology for the application of analytical results from the Bayesian network model to an event tree model, which is a probabilistic safety assessment method. The proposed method will provide insight into safety and cyber security risks.