• Title/Summary/Keyword: digital device

Search Result 2,209, Processing Time 0.025 seconds

Study on File Recovery Based on Metadata Accoring to Linux Kernel (리눅스 커널에 따른 메타데이터 기반 파일 복원 연구)

  • Shin, Yeonghun;Jo, Woo-yeon;Shon, Taeshik
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.1
    • /
    • pp.77-91
    • /
    • 2019
  • Recent Linux operating systems having been increasingly used, ranging from automotive consoles, CCTV, IoT devices, and mobile devices to various versions of the kernel. Because these devices can be used as strong evidence in criminal investigations, there is a risk of destroying evidence through file deletion. Ext filesystem forensics has been studied in depth because it can recovery deleted files without depending on the kind of device. However, studies have been carried out without consideration of characteristics of file system which may vary depending on the kernel. This problem can lead to serious situations, such as those that can impair investigative ability and cause doubt of evidence ability, when an actual investigation attempts to analyze a different version of the kernel. Because investigations can be performed on various distribution and kernel versions of Linux file systems at the actual investigation site, analysis of the metadata changes that occur when files are deleted by Linux distribution and kernel versions is required. Therefore, in this paper, we analyze the difference of metadata according to the Linux kernel as a solution to this and recovery deleted file. After that, the investigating agency needs to consider the metadata change caused by the difference of Linux kernel version when performing Ext filesystem forensics.

Comparative Analysis between Super Loop and FreeRTOS Methods for Arduino Multitasking (아두이노 멀티 태스킹을 위한 수퍼루프 방식과 FreeRTOS 방식의 비교 분석)

  • Gong, Dong-Hwan;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.133-137
    • /
    • 2018
  • Arduino is a small microcomputer that is used in a variety of industry fields and especially is widely used as an open source hardware IoT device. The multi-tasking method of Arduino is divided into super loop timing and RTOS thread method. The super loop timing method is simple and easy to understand. However, when one task is long, it affects the execution of the next task. In addition, RTOS threading has the advantage of being able to run without being influenced by other work time. However, Arduino, a small microcomputer, has a disadvantage in that, when the number of threads increases, the context switching time of the thread causes additional time not included in the super loop timing method have. In this paper, we use Arduino Uno R3 and FreeRTOS to analyze these different features, and the task for the experiment is to send 8000 digital signals to the built-in LED port. If two tasks of the same size are executed, the super loop method executes 3 ms faster than FreeRTOS multitasking. If multiple tasks are executed simultaneously, superloop type task is sequential execution and difference in execution time between first task and last task is large. FreeRTOS method can be executed concurrently, but execution time delay of about 30 ms occurs in context switching time.

Proposal and Analysis of Primality and Safe Primality test using Sieve of Euler (오일러체를 적용한 소수와 안전소수의 생성법 제안과 분석)

  • Jo, Hosung;Lee, Jiho;Park, Heejin
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.438-447
    • /
    • 2019
  • As the IoT-based hyper-connected society grows, public-key cryptosystem such as RSA is frequently used for encryption, authentication, and digital signature. Public-key cryptosystem use very large (safe) prime numbers to ensure security against malicious attacks. Even though the performance of the device has greatly improved, the generation of a large (safe)prime is time-consuming or memory-intensive. In this paper, we propose ET-MR and ET-MR-MR using Euler sieve so it runs faster while using less memory. We present a running time prediction model by probabilistic analysis and compare time and memory of our method with conventional methods. Experimental results show that the difference between the expected running time and the measured running time is less than 4%. In addition, the fastest running time of ET-MR is 36% faster than that of TD-MR, 8.5% faster than that of DT-MR and the fastest running time of ET-MR-MR is 65.3% faster than that of TD-MR-MR and similar to that of DT-MR-MR. When k=12,381, the memory usage of ET-MR is 2.7 times more than that of DT-MR but 98.5% less than that of TD-MR and when k=65,536, the memory usage of ET-MR-MR is 98.48% less than that of TD-MR-MR and 92.8% less than that of DT-MR-MR.

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Accuracy Analysis for Slope Movement Characterization by comparing the Data from Real-time Measurement Device and 3D Model Value with Drone based Photogrammetry (도로비탈면 상시계측 실측치와 드론 사진측량에 의한 3D 모델값의 정확도 비교분석)

  • CHO, Han-Kwang;CHANG, Ki-Tae;HONG, Seong-Jin;HONG, Goo-Pyo;KIM, Sang-Hwan;KWON, Se-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.234-252
    • /
    • 2020
  • This paper is to verify the effectiveness of 'Hybrid Disaster Management Strategy' that integrates 'RTM(Real-time Monitoring) based On-line' and 'UAV based Off-line' system. For landslide prone area where sensors were installed, the conventional way of risk management so far has entirely relied on RTM data collected from the field through the instrumentation devices. But it's not enough due to the limitation of'Pin-point sensor'which tend to provide with only the localized information where sensors have stayed fixed. It lacks, therefore, the whole picture to be grasped. In this paper, utilizing 'Digital Photogrammetry Software Pix4D', the possibility of inference for the deformation of ungauged area has been reviewed. For this purpose, actual measurement data from RTM were compared with the estimated value from 3D point cloud outcome by UAV, and the consequent results has shown very accurate in terms of RMSE.

Red fluorescence of oral bacteria is affected by blood in the growth medium (성장배지 혈액 유무가 구강미생물의 적색 형광 발현에 미치는 영향)

  • Jeong, Seung-Hwa;Yang, Yong-Hoon;Lee, Min-Ah;Kim, Se-Yeon;Kim, Ji-Soo
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.4
    • /
    • pp.290-295
    • /
    • 2017
  • Objectives: Dental plaque emits red fluorescence under a visible blue light near the ultra-violet end of the light spectrum. The fluorescence characteristics of each microorganism have been reported in several studies. The aim of this study was to evaluate changes in red fluorescence of oral microorganisms that is affected by blood in the culture media. Methods: The gram-positive Actinomyces naeslundii (AN, KCTC 5525) and Lactobacillus casei (LC, KCTC 3109) and gram negative Prevotella intermedia (PI, KCTC 3692) that are known to emit red fluorescence were used in this study. Each bacterium was activated in broth and cultivated in different agar media at $37^{\circ}C$ for 7 days. Tryptic soy agar with hemin and vitamin $K_3$ (TSA), TSA with sheep blood (TSAB), basal medium mucin (BMM) medium, and BMM with sheep blood (BMMB) were used in this study. Fluorescence due to bacterial growth was observed under 405-nm wavelength blue light using the quantitative light-induced fluorescence-digital (QLF-D) device. The red, green, and blue fluorescence values of colonies were obtained using image-analysis software and the red to green ratio (R/G value) and red to total RGB ratio (R/RGB value) were calculated for quantitative comparison. Results: The QLF-D images of the AN, LC, and PI colonies showed red fluorescence in all media, but the fluorescence of all bacteria was reduced in TSA and BMM media, compared with in TSAB and BMMB media. Both the R/G and the R/RGB values of all bacteria were significantly reduced in growth media without blood (P<0.001). Conclusions: Based on this in vitro study, it can be concluded that red fluorescence of oral bacteria can be affected by growth components, especially blood. Blood-containing medium could be a significant factor influencing red fluorescence of oral bacteria. It can be further hypothesized that bleeding in the oral cavity can increase the red fluorescence of dental plaque.

Efficient Privacy-Preserving Duplicate Elimination in Edge Computing Environment Based on Trusted Execution Environment (신뢰실행환경기반 엣지컴퓨팅 환경에서의 암호문에 대한 효율적 프라이버시 보존 데이터 중복제거)

  • Koo, Dongyoung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.305-316
    • /
    • 2022
  • With the flood of digital data owing to the Internet of Things and big data, cloud service providers that process and store vast amount of data from multiple users can apply duplicate data elimination technique for efficient data management. The user experience can be improved as the notion of edge computing paradigm is introduced as an extension of the cloud computing to improve problems such as network congestion to a central cloud server and reduced computational efficiency. However, the addition of a new edge device that is not entirely reliable in the edge computing may cause increase in the computational complexity for additional cryptographic operations to preserve data privacy in duplicate identification and elimination process. In this paper, we propose an efficiency-improved duplicate data elimination protocol while preserving data privacy with an optimized user-edge-cloud communication framework by utilizing a trusted execution environment. Direct sharing of secret information between the user and the central cloud server can minimize the computational complexity in edge devices and enables the use of efficient encryption algorithms at the side of cloud service providers. Users also improve the user experience by offloading data to edge devices, enabling duplicate elimination and independent activity. Through experiments, efficiency of the proposed scheme has been analyzed such as up to 78x improvements in computation during data outsourcing process compared to the previous study which does not exploit trusted execution environment in edge computing architecture.

Effect of alternative farrowing pens with temporary crating on the performance of lactating sows and their litters

  • Si Nae, Cheon;So Hee, Jeong;Guem Zoo, Yoo;Se Jin, Lim;Chan Ho, Kim;Gul Won, Jang;Jung Hwan, Jeon
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.574-587
    • /
    • 2022
  • This study was performed to development the alternative farrowing pen (AFP) and to investigate performance and behavior of lactating sows and their litter. A total of 64 multiparous sows were randomly divided into two groups and were allocated to farrowing crates (FCs) and AFPs. The AFPs contained a crate and support bars that could be folded to provide the sows with extra space on day 5 postpartum. Behavior was recorded by charge-coupled device cameras and digital video recorders, and the data were scanned every 2 min to obtain an instantaneous behavioral sample. Farrowing systems did not affect feed intake, back-fat thickness, litter size and piglet weight at birth and weaning (p > 0.05). In addition, there were no differences in the number of crushed piglets between the two farrowing systems (p > 0.05). However, the weaning-to-estrus interval was shorter in the sows of the AFPs than in thous of the FCs (p < 0.05). The sows spent most of their time lying down during the lactating period, at about 80% lateral recumbency and 10%-15% ventral recumbency. The only significant differences were in the feeding and drinking behavior between sows in the two farrowing systems (p < 0.05). The FC sows displayed more feeding and drinking behavior than the AFP sows, especially in the late lactating period (p < 0.05). Piglets in the FCs tended to spend more time walking than piglets in the AFPs (p < 0.05), whereas there were no differences in suckling and lying behavior between piglets in the two farrowing systems (p > 0.05). It is concluded that the AFPs with temporary crating until day 4 postpartum did not negatively affect performance and crushed piglet compared with the FCs. It also may improve animal welfare by allowing sows to move and turn around during the lactating period. Further research is needed to find suitable housing designs to enhance productivity and animal welfare.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Transparent Near-infrared Absorbing Dyes and Applications (투명 근적외선 흡수 염료 및 응용 분야)

  • Hyocheol Jung;Ji-Eun Jeong;Sang-Ho Lee;Jin Chul Kim;Young Il Park
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.207-212
    • /
    • 2023
  • Near-infrared (NIR) absorbing dyes have been applied to various applications such as optical filters, biotechnology, energy storage and conversion, coating additive, and traditionally information-storage materials. Because image sensors used in cellphones and digital cameras have sensitivity in the NIR region, the NIR cut-off filter is essential to achieving more clear images. As energy storage and conversion have been important, diverse NIR absorbing materials have been developed to extend the absorption region to the NIR region, and NIR absorbing materials-based research has proceeded to improve device performances. Adding NIR-absorbing dye with a photo-thermal effect to a self-healable coating system has been attractive for future mobility technology, and more effective self-healing properties have been reported. In this report, the chemical structures of representative NIR-absorbing dyes and state of the art research based on NIR-absorbing dyes are introduced.