• 제목/요약/키워드: digital calibration

검색결과 377건 처리시간 0.026초

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

ISO/TC 108/SC 3 표준 제·개정 현황 (Current Status of ISO/TC 108/SC 3 Standards and Drafts under Development)

  • 정완섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.540-542
    • /
    • 2014
  • This paper introduces main activities of ISO/TC 108/SC 3 and published standards. Two working groups (WG 1 and WG 6) have been orgnized to review and revise ISO standards, specifically related to measurement and calibration subjects of vibration and shocks. A new joint working group (JWG1) with IEC/SC 47E (Semiconductor acceleration calibration) has started to deal with calibration methods for analog and digital output MEMS accelerometers. Finally, Published ISO standards, technically super-visored by ISO/TC 108/SC 3, are listed in this paper to help readers understand their main contents.

  • PDF

Development of standard calibration equipment for the rain gauges

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2468-2473
    • /
    • 2005
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the error for the rainfall intensity and obtained useful result through the proposed calibration method.

  • PDF

신경회로망을 이용한 산업용 로봇(AM1)의 역보정에 관한 연구 (A Study on the Inverse Calibration of Industrial Robot(AM1) Using Neural Networks)

  • 안인모
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.131-136
    • /
    • 1999
  • This paper proposes the robot inverse calibration method using a neural networks. A highorder networks called Pi-Sigma networks has been used. The Pi-Sigma networks uses linear summing units in the hidden layer and product unit in output layer. The inverse calibration model which compensates the difference of joint variables only between measuring value and analytic value about the desired pose(position, orientation) of a robot is proposed. The compensated values are determined by using the weights obtained from the learning process of the neural networks previously. To prove the reasonableness, the SCARA type direct drive robot(4-DOF) and anthropomorphic robot(6-DOF) are simulated. It shows that the proposed calibration method can reduce the errors of the joint variables from $\pm$2$^{\circ}$to $\pm$ 0.1$^{\circ}$.

  • PDF

질량측정에 의한 우량계 표준교정시스템 개발 (Development of Standard Calibration System for the Rain Gauges by Weighting Method)

  • 신강욱;홍성택
    • 제어로봇시스템학회논문지
    • /
    • 제12권8호
    • /
    • pp.818-823
    • /
    • 2006
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the uncertainty for the rainfall intensity and obtained useful result through the proposed calibration method.

매개변수 보정 전문가시스템을 이용한 HSPF 모형의 수문 매개변수 보정 및 적용성 평가 (Evaluation of Applicability and Hydrologic Parameter Calibration for HSPF Model using Expert System for HSPF)

  • 김성민;김상민
    • 한국농공학회논문집
    • /
    • 제55권4호
    • /
    • pp.13-20
    • /
    • 2013
  • The purpose of this study was to evaluate the applicability of the HSPEXP expert system for the calibration of the Hydrological Simulation Program - Fortran (HSPF) for the study watershed. HSPEXP offers advice to the modeler, suggesting parameter changes that might result in better representation of a river basin and provides explanations supporting the recommended parameter changes. The study watershed, Sancheong, is located within the Nakdong River Basin and having the size of $1,072.4km^2$. Input data for the HSPF model were obtained from the landuse map, digital elevation map, meteorological data and others. Water flow data from 2006 to 2008 were used for calibration and from 2009 to 2010 were for validation. Using the HSPEXP expert system, hydrological parameters were adjusted based on total volume, then low flows, storm flows, and finally seasonal flows. For the calibration and validation period, all the HSPEXP model performance criteria were satisfied.

LCOS 마이크로디스플레이 구동용 보정회로 설계 (Design of Calibration Circuit for LCOS Microdisplay)

  • 이연성;위정욱;한충우;송남철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.469-471
    • /
    • 2022
  • 본 논문에서는 아날로그 구동 방식의 4K UHD LCOS 패널을 구동하기 위해 디지털 픽셀을 아날로그 픽셀로 변환하는 과정에서 발생되는 이득 오차, DC 옵셋, 샘플링 클럭의 위상 오차를 보정하기 위한 보정회로의 구현 방법을 기술한다. 제안된 보정회로는 이득 및 DC 옵셋 보정 회로와 샘플링 클럭 위상 조정 회로로 구성되며, FPGA와 비디오 앰프를 이용하여 구현하였다.

  • PDF

비측정용 디지털 카메라의 효율적인 자체 검정을 위한 대상지 구성 (A Photogrammetric Network and Object Field Design for Efficient Self-Calibration of Non-metric Digital Cameras)

  • 오재홍;어양담;이창노
    • 한국측량학회지
    • /
    • 제24권3호
    • /
    • pp.281-288
    • /
    • 2006
  • 최근 비 측정용 디지털 카메라의 화소수가 급증하고, 카메라 단가 또한 저렴해져 문화재 및 시설물의 3차원 공간 측량 등에도 이를 활용할 수 있게 되었다. 그러나 비 측정용 카메라를 측량용으로 활용하기 위해서는, 카메라 자체검정을 통해 내부 표정요소를 정확히 계산해내야 한다. 이를 위해서는 적절한 검정 대상지의 구성 및 촬영계획이 선행되어야 한다. 본 연구에서는 지상기준점 수, 사진의 수, 기준점의 차원(2차원 및 3차원)등의 조건에 따른 카메라 자체 검정 정확도에 대하여 분석하였다. 실험 결과, 근거리 사진측량을 위한 자체검정 대상지 구축 시 수직사진을 포함하는 3장 이상의 사진으로 안정된 정확도를 얻을 수 있음을 알 수 있었고, 3차원 복원을 목적으로 하는 경우, 평면상의 지상기준점 10점으로도 높은 정회도의 결과를 얻을 수 있음을 알 수 있었다.

지상기준점을 이용한 디지털카메라 Boresight Calibration (Digital Photogrammetry Camera Boresight Calibration Using Ground Control Points)

  • 이용욱
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.293-298
    • /
    • 2014
  • 최근의 항공사진측량은 디지털항공사진 카메라와 GPS/ INS를 결합한 통합 센서를 활용하여 Direct Georeferencing 하는 방법이 보편화됐으며, 이를 기반으로 신속하고 정확하게 사진측량을 수행할 수 있게 되었다. Direct Georeferencing을 통해 얻을 수 있는 외부표정요소의 정확도는 GPS/INS에 의해 결정되는데, INS의 회전량 차이를 결정하여 자세정보를 정확하게 계산하는 것이 중요하다. 이를 위해 Boresight Calibration으로 INS의 회전량 차이 및 GPS와 INS 간의 간격과 같은 Misalignment를 결정해야 한다. 이때 많은 수의 지상기준점을 이용하여 항공삼각측량과 Boresight Calibraiton을 하게 되는데, 지상기준점의 수와 배열, 위치에 따라 그 결과가 다르게 나타난다. 연구 결과 모든 사진코스에 지상기준점을 배치할 경우 점수의 변화에 따른 Misalignment와 외부표정요소는 큰 변화가 없었으나 지상기준점이 없는 코스가 있을 경우 그 값들에서 차이가 크게 발생하였다.

특성이 다른 지게차 적재 중량 센서의 초기 값 오차 보정 (Error Calibration of Initial Value of Weight Measuring Sensors with Different Feature of Forklift)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.214-220
    • /
    • 2019
  • 산업현장에서의 안전사고 빈도가 높은 지게차 전복의 주요 원인인 과적을 방지하기 위해 개발된 앵커(anchor) 볼트 형태의 strain 게이지 센서의 초기 값 오차를 보정하는 방법을 제안하였다. Strain 게이지 센서의 초기 값 오차는 앵커 볼트의 물리적이고 기계적 오차와 환경적 문제에기인하는 것을 확인하였다. 이러한 원인들을 제조 공정에서 제거하는 것은 본 연구의 범위를 벗어나는 것이기 때문에 제반 원인들을 고려한 보정 값을 찾고, 이 보정 값으로 strain 게이지 센서부를 구성하는 ADC 모듈의 초기 값을 보정하는 방법을 적용하였다. 보정 값 도출을 위하여 선형 보간법을 채택하였다. 도출한 보정 값을 4개의 strain 게이지 센서에 적용하여 시험한 결과 4개의 센서 모두 실제 중량 값과의 차이가 5% 이내가 되는 것을 확인하였다. 아울러 초기 값 보정 전에는 센서들의 ADC 값과 적재 중량 실제 값의 상관성이 없었던 점도 동시에 해결할 수 있었다.