The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments (흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향)

  • Yoon, Jung-Gyu;Lee, Geon-Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF

Echo-PIV: in vivo Flow Measurement Technique (에코 PIV: in vivo 유동 측정기법)

  • kim Hyoung-Bum;Hertzberg Jean;Shandas Robin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.26-35
    • /
    • 2005
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) method has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window of offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow and pulsatile flow showed good agreement with both optical PIV measurements and the known analytic solution. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

  • PDF

Changes of Facial Blood Flow Rates and Skin Temperature by Application of Gagam-Jawoonaek after Facial Acupuncture (안면부(顔面部) 침술(鍼術) 자극 후 가감자운액(加減紫雲液) 도포가 혈류량 및 피부 온도에 미치는 영향)

  • Kim, Tae Yeon;Hwang, Dong Seok;Kim, Hee Taek;Kim, Yong Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.5
    • /
    • pp.650-659
    • /
    • 2013
  • To investigate the effects of facial blood flow rates(FBFR) and facial skin temperature(FST) generated by Gagam-Jawoonaek(GJ) application(appl.) after Miso Facial Rejuvenation Acupuncture(MFRA). Ten people in their twenties to fifties with no skin diseases were recruited. We randomly divided subjects two groups(A, B) and set the GJ appl. site(group A - right side, group B - left side). MFRA was performed on both sides of their face. Immediately after acupuncture treatment(AT treat.), GJ was applied only half of the face. We measured their FBFR using Laser Doppler Perfusion Imaging(LDPI) and FST using Digital Infrared Thermal Imaging(DITI) at pre-AT treat., immediately after AT treat., twenty and sixty minutes after GJ appl.. We analyzed data using Mann-Whitney test and Wilcoxon test(p < 0.05). After MFRA treat., FBFR on both sides increased. Twenty minutes after JW appl., the changes of FBFR on GJ appl. side($122.9{\pm}43.1PU$) were bigger than GJ non-appl. side($80.9{\pm}38.4PU$), a statistically significant decrease. Sixty minutes after application, FBFR on both sides were recovered almost at the same level as that of pre-AT treat. After MFRA treat., FST on both sides increased. Twenty minutes after GJ appl., the changes of FST on GJ appl. side($1.1{\pm}0.6^{\circ}C$) were comparable to that of GJ non-appl. side($1.2{\pm}0.5^{\circ}C$). Sixty minutes after application, FST on both sides were recovered almost at the same level as that of pre-AT treat.. Gagam-Jawoonaek could decrease facial blood flow rates.

Modeling of the Artery Tree in the Human Upper Extremity and Numerical Simulation of Blood Flow in the Artery Tree (상지동맥 혈관계의 모델링과 혈유동의 전산수치해석)

  • Kim, Keewon;Kim, Jaeuk U.;Beak, Hyun Man;Kim, Sung Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.221-226
    • /
    • 2016
  • Since arterial disease in the upper extremity is less common than that in the lower extremity, experimental and numerical investigations related to upper extremity have been rarely performed. We created a three-dimensional model of the arteries, larger than approximately 1 mm, in a Korean adult's left hand (from brachial to digital arteries), from 3T magnetic resonance imaging (MRI) data. For the first time, a three-dimensional computational fluid dynamic method was employed to investigate blood flow velocity, blood pressure variation, and wall shear stress (WSS) on this complicated artery system. Investigations were done on physiological blood flows near the branches of radial and deep palmar arch arteries, and ulnar and superficial palmar arch arteries. The flow is assumed to be laminar and the fluid is assumed to be Newtonian, with density and viscosity properties of plasma.

Development of Echo PIV Using Ultrasound Contrast Agent (초음파 조영제를 애용한 Echo PIV 기법의 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

The Method of Thermograph using Thermoelectric Sensor Device in the Carbon fiber Thick Films (Carbon fiber 후막형 열전센서 소자를 이용한 적외선 체열진단)

  • Song, Min-Jong;Dong, Kyung-Rae;Kim, Chang-Bok;Choi, Seong-Kwan;Park, Yong-Soon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Thick films of carbon fiber were prepared by a heating element of plan shape made in Darin co., We have investigated surface morphology of the specimen depending on heat-treatment temperatures. Scanning electron microscope(SEM) image of carbon fiber thick films of the specimen heat treated shows a grain growth at $1200^{\circ}C$ and becomes a poly-crystallization at $1350^{\circ}C$. The variation of resistivity at the thermally annealed specimen above $600^{\circ}C$ depends on type of the substrates. It may be due to a variation of film thickness and a difference of interfacial phenomena. A heating element of features was affected significantly by skin blood and quantity of heat of the body physiological function. After radiation of farinfrared for plate heating element, the function of biometric physiological is considered of skin blood flow and calorie which greatly affects on individuals. Electromagnetic wave was not influence on the body.

  • PDF

External Carotid Artery Angioplasty and Stenting Followed by Superficial Temporal Artery to Middle Cerebral Artery Anastomosis

  • Ko, Jun-Kyeung;Lee, Sang-Weon;Lee, Tae-Hong;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.488-491
    • /
    • 2009
  • A 31-year-old man presented with right hemiparesis, and magnetic resonance imaging revealed a small infarct at left basal ganglia. Digital subtraction angiography showed left cervical internal carotid artery (ICA) occlusion and severe stenosis of the ipsilateral external carotid artery (ECA) with collateral cerebral circulation fed by ECAs. Based on the results of a functional evaluation of cerebral blood flow, we performed preventive ECA angioplasty and stenting for advanced ECA stenosis to ensure sufficient blood flow to the superficial temporal artery. Eight weeks later, superficial temporal artery to middle cerebral artery (STA-MCA) anastomosis was performed. His postoperative course was uneventful and no additional transient ischemic attacks have occurred. To our knowledge, this is the first report of preventive angioplasty and stenting for advanced narrowing of an ECA before STA-MCA anastomosis for ipsilateral ICA occlusion.

The Changes of Sweating Area, Temperature and Blood Flow in the Upper and Lower Extremity after Hyperhidrosis Operations (다한증수술후 발한분포 및 상하지의 온도변화와 혈류량변화)

  • 김용환;장윤희;문석환;조건현;왕영필;김세화;곽문섭;김학희;장혜숙
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.456-460
    • /
    • 1999
  • Background: Thoracic sympathectomy for hyperhidrosis has been recognized as an effective treatment using thoracoscopic devices and operative techniques, but the satisfaction has decreased due to a compensatory hyperhidrosis. Therefore, the postoperative results and compensatory hyperhidrosis were analyzed. We also measured the temperature differences in the hand and foot during the preoperative and postoperative periods and measured the blood flow of upper and lower extremities. Material and Method: From December 1995 to July 1998, total of 47 patients with hyperhidrosis underwent sympathectomy via VATS at the Department of Thoracic and Cardiovascular Surgery, Kangnam St. Mary's Hospital. The patients were evaluated for preoperative and postoperative temperature changes on the finger and toe, and preoperative and postoperative blood flows were measured by the Doppler examination on the digital artery, radial artery and dorsalis pedis artery. Result: There were no operative deaths but some complications existed: 7 pneumothorax, 3 recurrence and 1 Honor syndrome. Ninety-five percent of the patients also had compensatory sweating especially in the trunk. There were 5 patients who regretted recurring the operation because of the compensatory sweating. Sweating decreased in 46% of the sole hyperhidrosis patients. The temperature difference between preoperation and postoperation was 1$^{\circ}C$ on the right hand side and 1.9$^{\circ}C$ on the left hand side(P<0.05). There was no significant temperature difference on the sole. Blood flow increased significantly in the palm, but no difference in the sole. Conclusion: In conclusion, thoracic sympathectomy for hyperhidrosis is a safe and effective treatment but satisfaction has been decreased by the compensatory sweating; therefore, it is important to thoroughly explain the compensatory sweating prior to surgery. Improvement of the plantar hyperhidrosis is not due to a physiological change, but to a psychological stability.

  • PDF

The effects of optimizing blood inflow in the pedicle on perforator flap survival: A pilot study in a rat model

  • Olariu, Radu;Moser, Helen Laura;Lese, Ioana;Sabau, Dan;Georgescu, Alexandru Valentin;Grobbelaar, Adriaan Ockert;Constantinescu, Mihai Adrian
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.209-216
    • /
    • 2020
  • Background Perforator flaps have led to a revolution in reconstructive surgery by reducing donor site morbidity. However, many surgeons have witnessed partial flap necrosis. Experimental methods to increase inflow have relied on adding a separate pedicle to the flap. The aim of our study was to experimentally determine whether increasing blood flow in the perforator pedicle itself could benefit flap survival. Methods In 30 male Lewis rats, an extended posterior thigh perforator flap was elevated and the pedicle was dissected to its origin from the femoral vessels. The rats were assigned to three groups: control (group I), acute inflow (group II) and arterial preconditioning (group III) depending on the timing of ligation of the femoral artery distal to the site of pedicle emergence. Digital planimetry was performed on postoperative day (POD) 7 and all flaps were monitored using laser Doppler flowmetry perioperatively and postoperatively in three regions (P1-proximal flap, P2-middle of the flap, P3-distal flap). Results Digital planimetry showed the highest area of survival in group II (78.12%±8.38%), followed by groups III and I. The laser Doppler results showed statistically significant higher values in group II on POD 7 for P2 and P3. At P3, only group II recorded an increase in the flow on POD 7 in comparison to POD 1. Conclusions Optimization of arterial inflow, regardless if performed acutely or as preconditioning, led to increased flap survival in a rat perforator flap model.

Understanding of Perfusion MR Imaging (관류자기공명영상의 이해)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF