• Title/Summary/Keyword: digital X-ray imaging

Search Result 225, Processing Time 0.02 seconds

Clinical evaluation of Acupuncture on Herniated of Cervical Intervertebral Disc by DITI (컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)으로 본 경추추간판(頸椎椎間板) 탈출증(脫出症)의 침구치료효과(鍼灸治療效果))

  • Lee, Geon-Mok
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.132-140
    • /
    • 1995
  • Object : This study is designed to evaluate the correlation between the data of DITI(Digital Infrared Thermographic Imaging)examination and the changes of clinical symptom after the therapy of acupuncture in the patients with herniated cervical intervertebral disc. Content : The conservative therapy with acupuncture was performed during $4{\sim}5$ weeks, The acupuncture points of SI3, B62, TE3, G34, LI4, S36, GV26, G21, SII5 were used. In the pre- and post therapy, DITI examinations were performed in patients who had HIVD and were treated by acupuncture simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-acupuncture and post-acupuncture. Setting : The standard routine thermoghaphic examinations were performed with thermography(DITI) in the 15 patients with lumbar disc herniations at pre- and post acupuncture. Patient : Thermographic imaging of 15 cases were analyzed. They has disc herniations in X-ray, CT scan and MRI and they were treated by acupuncture theraphy in our hospital from March, 1994 to January, 1995. Result : 1) The causes were trauma(60%), retention of phlegm and fluid(8.7%) and cold & moisture(33.3%) 2) Levels of herniated cervical disc are C2/3(1 case). C3/4(2 cases), C5/6 & C6/7 (2 cases), C6/7(4 cases), Normal(6 cases). 3) Classifications of thermographic pattern are radiculopathy(80%), spot(13.3%), and nonspecific(6.7%) in order. 4) In evaluation Results of clinical symptom are Excellent(80%), Good(6.7%), and Poor(6.7%). Data of DITI are Excellent(80%), Good(6.7%), Fair(6.7%), and Poor(6.7%). Conclusion ; Acupuncture showed good results over 86.7% in clinical evaluation and 86.7% in DITI. Thermographic examination was valuable in the evaluation of therapeutic effect of acupuncture treatment.

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

Change of MTF for Sampling Interval in Digital Detector (디지털 검출기에서 샘플링 간격에 따른 MTF의 변화)

  • Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.225-230
    • /
    • 2014
  • Assessments of medical image was improved in accordance with development of medical imaging systems. One of them is edge method to determining MTF(Modulation Transfer Function) based on the Fujita method. Fujita was reduced sampling interval used slightly angulated slit to the direction of pixel array and composited finely sampled LSF to determine presampling MTF. In this study, we investigate the effect of sampling interval on the MTF under a digital imaging system by changing wire angle. The wire method was equivalent to the slit method except signal appearance. A Simens's MAMMOMAT Inspiration with $0.085{\times}0.085mm^2$ pixel size made by amorphous selenium was used and 96% accuracy on MTF in twice sampling interval compared with Fujita was obtained. However, three times of sampling interval showed 93% accuracy on 50% of MTF and 85% accuracy on 10% of MTF.

A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice (흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Chai, Kyu-Yun;Han, Beom-Hee;Han, Sang-Hyun;Hong, Dong-Hee;Han, Tae-Jong;Park, Sung-Hoon;Mo, Eun-Hee;Jun, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.367-375
    • /
    • 2014
  • In this thesis we observe microvascular structure in mice by using micro-computed tomography (CT), which is high-resolution X-ray imaging equipment that can acquire Real-time dynamic image, and it aims to investigate the usefulness of micro-CT developed by Institute for Radiological Imaging Science Wonkwang University School of Medicine. After acquiring the systemic images of rats, contrast-enhanced 3D images of vascular structures could be acquired by using Maximum Intensity Projection (MIP) and Volume Rending Technique (VRT), This was divided into each vascular system of head, abdomen and heart and systemic vascular system.

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

Detection method of proximal caries using line profile in digital intra-oral radiography (디지털 구내방사선사진에서 라인 프로파일을 이용한 인접면우증식의 인지 방법)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Kim, Gyu-Tae;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.185-189
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. Materials and Methods : The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Results : Mean values of D were $0.0354{\pm}0.0155$ in non-caries and $0.2632{\pm}0.0982$ in caries (p<0.001). Conclusion : The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  • PDF

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.