• Title/Summary/Keyword: diffusion coefficients

Search Result 534, Processing Time 0.026 seconds

Synthesis and electrochemical properties of layered $Li[Ni_xCo_{1-2x}Mn_x]O_2$ materials for lithium secondary batteries prepared by mechanical alloying (기계적 합금법을 이용한 리튬 2차 전지용 층상 양극물질 $Li[Ni_xCo_{1-2x}Mn_x]O_2$ 의 합성 및 전기화학적 특성에 관한 연구)

  • 박상호;신선식;선양국
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.16-16
    • /
    • 2002
  • The presently commercialized lithium-ion batteries use layer structured LiCoO₂ cathodes. Because of the high cost and toxicity of cobalt, an intensive search for new cathode materials has been underway in recent years. Recently, a concept of a one-to-one solid state mixture of LiNO₂ and LiMnO₂, i.e., Li[Ni/sub 0.5/Mn/sub 0.5/]O₂, was adopted by Ohzuku and Makimura to overcome the disadvantage of LiNiO₂ and LiMnO₂. Li[Ni/sub 0.5/Mn/sub 0.5/]O₂ has the -NaFeO₂ structure, which is characteristic of the layered LiCoO₂ and LiNiO₂ structures and shows excellent cycleability with no indication of spinel formation during electrochemical cycling. Layered Li[Ni/sub x/Co/sub 1-2x/Mn/sub x/]O₂ (x = 0.5 and 0.475) materials with high homogeneity and crystallinity were synthesized using a mechanical alloying method. The Li[Ni/sub 0.475/Co/sub 0.05/Mn/sub 0.475/]O₂ electrode delivers a high discharge capacity of 187 mAh/g between 2.8 and 4.6 V at a high current density of 0.3 mA/㎠(30 mA/g) with excellent cycleability. The charge/discharge and differential capacity vs. voltage studies of the Li[Ni/sub x/Co/sub 1-2x/Mn/sub x/]O₂ (x = 0.5 and 0.475) materials showed only one redox peak up to 50 cycles, which indicates that structural phase transitions are not occurred during electrochemical cycling. The magnitude of the diffusion coefficients of lithium ions for Li[Ni/sub x/Co/sub 1-2x/Mn/sub x/]O₂(x = 0.5 and 0.475) are around 10/sup -9/ ㎠/s measured by the galvanostatic intermittent titration technique (GITT).

  • PDF

Experimental Examinations on the Phenomenon of Transfer and Moisture Diffusion in Wood (목재내(木材內)의 수분확산(水分擴散) 및 전달현상(傳達現象)에 관한 실험적 검정(檢定))

  • Lee, Weon-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.75-80
    • /
    • 1996
  • The purpose of this study is to clarify the mechanism of moisture transfer depend on the thickness of the spruce(Picea sitchensis Carr.). Therefore, as the basic research of moisture transmission, the amount of moisture transmission and the moisture distribution in specimens and temperature of it's surfaces in vapor transmission process were investigated. The experiment was conducted in a steady state. and the moisture distribution was measured by knife cutting and weighing the specimens. The following conclusions were obtained ; 1. It can be found that distribution of moisture in the specimen can be approximated by two different straight lines intersecting at nine or ten percent moisture content. The amount of moisture movement defends on the gradient of moisture in the wood. 2. It is investigated that the wood surface moisture contents(MCs) are less for thinner specimens than for thick ones on the absorption side. On the other hand, the wood surface MCs are greater for thinner specimens than for thick ones on the desorption side. The main factor that affects the EMC of wood would be temperature when the relative humidity of atmosphere is constant. The specimen generate heat with the absorption and desorption process. In addition, the velocities of moisture transmission varied with the thicknesses of specimens. If the temperature of wood becomes greater, its MC decreases. Then the difference between surface MC and EMC of adsorption and desorption side becomes greater for thinner specimens. Therefore it is considered that the coefficients of moisture transfer decreases with the increases of the specimens' thicknesses.

  • PDF

Joining and properties of electrode for CoSb3 thermoelectric materials prepared by a spark plasma sintering method (방전 플라즈마 소결법을 이용한 CoSb3계 열전재료의 전극 접합 및 특성)

  • Kim, K.H.;Park, J.S.;Ahn, J.P.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.1
    • /
    • pp.30-34
    • /
    • 2010
  • $CoSb_3$-based skutterudite compounds are promising candidates as thermoelectric (TE) materials used in intermediate temperature region. In this study, sintering of $CoSb_3$ powder and joining of $CoSb_3$ to copper-molybdenum electrode have been simultaneously performed by spark plasma sintering technique. The Ti foil was used for preventing the diffusion of copper into $CoSb_3$ and the Cu : Mo = 3 : 7 Vol. ratio composition was selected by the consideration of thermal expansion coefficients. The insertion of Ti interlayer between Cu-Mo and $CoSb_3$ was effective to join $CoSb_3$ to Cu-Mo by forming an intermediate layer of $TiSb_2$ at the Ti-$CoSb_3$ boundary. However, the formation of TiSb and TiCoSb intermediate layers deteriorated the joining properties by the generation of cracks in the interface of intermediate layer/$CoSb_3$ and intermediate/intermediate layers.

Shape-Selective Catalytic Reactions of Toluene with n-Propylalcohol Over ZSM-5 Zeolites (ZSM-5 제올라이트에서 n-프로필알코올의 톨루엔에 대한 형상 선택적 촉매반응)

  • Han-Yun Lee;Byoung Joon Ahn
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.317-326
    • /
    • 1993
  • The acid catalytic reactions of toluene with n-propylalcohol were investigated and the adsorption experiments of dialkylbenzene isomers were carried out at 100$^{\circ}C$ over modified HZSM-5 zeolites. ZSM-5 zeolite was synthesized by the hydrothermal reaction using 4-propylammonium ion, sodium aluminate and colloidal silica etc., and several zeolite catalysts, including H-, K-, Sr-, P-Mg-HZSM-5, H-Y and H-mordenite, were prepared by conventional methods. The main reaction products of toluene with n-propylalcohol over HZSM-5 catalyst include not only xylenes, propyltoluenes, but also ethyltoluenes and high para-selectivity among dialkylbenzene isomers was observed on P-Mg-HZSM-5 zeolite. The diffusion coefficients of various p-dialkylbenzenes are nearly the same, about 1 ${times}$ 10$^{-10}$ cm$^2$/sec and that of m-xylene was about one tenth of o-xylene. These reaction and adsorption characteristics were interpreted in the light of the shape-selectivity related to related to the zeolite pore structure and the zeolitic acidity.

  • PDF

Separation Characteristics of Aqueous Isopropanol Solution by Pervaporation (투과증발에 의한 이소프로판올 수용액의 분리특성)

  • 이규일;김현진;김진환
    • Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.22-31
    • /
    • 1996
  • Pervaporation experiments of isopropanol-water mixtures through a polydimethytsiloxane(PDMS) membrane were carried out at 35$^{\circ}$C and the effect of isopropanol concentration on the separation characteristics was investigated. The total permeation rate showed the largest deviation from the ideal permeation rate at the isoprpanol volume fraction from 0.5 to 0.7, which resulted from the interaction effect between permeants. The plasticizing effect of isopropanol enhanced the permeation of water, while the existance of water resulted in the depression of isopropanol permeation. Both the permeation rate and the selectivity were predicted using Flory-Huggins thermodynamics and modified Maxwell-Stefan equation. The concentration-dependent diffusion coefficients were expressed by Vignes equation. The Flory-Huggins interaction parameter between isopropanol and water was calculated using excess Gibbs energy correlation and the interaction parameters between liquid and polymer membrane were determined by equilibrium swelling experiments. The predicted permeation rates were in accord with the experimental ones within maximum error range of 35 %. The predicted permeation selectivities were in good agreement with the experimental values.

  • PDF

Effect Of Substituted-Fe for the Charge-discharge behavior Of $LiMn_{2}O_{4}$cathode materials (Fe 치환이$LiMn_{2}O_{4}$정극 활물질의 충방전 특성에 미치는 영향)

  • 정인성;김민성;구할본;손명모;이헌수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.548-551
    • /
    • 2000
  • Spinel phase LiF $e_{y}$M $n_{2-y}$ $O_4$samples are synthesized by calcining a LiOH.$H_2O$, Mn $O_2$and F $e_2$ $O_3$mixture at 80$0^{\circ}C$ for 36h in air. Preparing LiF $e_{y}$M $n_{2-y}$ $O_4$showed spinel phase with cubic phase. The ununiform distortion of the crystallite of the spinel LiF $e_{y}$M $n_{2-y}$ $O_4$was more stable than that of the pure. The discharge capacity of the cathode for the Li/LiF $e_{0.1}$M $n_{1.9}$ $O_4$cell at the first than that of the pure. The discharge capacity of the cathode for the Li/LiF $e_{0.1}$M $n_{1.9}$ $O_4$cell at the first cycle and at the 70th cycle was about 113 and 90mAh/g, respectively. This cell capacity was retained about 82% of the first cycle after 70th cycle. Impedance profile of this cell was more stable than that pure. The resistance, the capacitance and chemical diffusion coefficients of lithium ion showed approximately 80$\Omega$, 36133.87$\mu$F ; 1.4$\times$10$^{-8}$ c $m^2$ $s^{-1}$ , respectively. , respectively.ely.

  • PDF

Permeation Apparatus for on-line Measurement of the Permeation Characteristics through Dense Polymeric Membranes (투과특성의 on-line 측정을 위한 투과장치)

  • 염충균;김범식;김철웅;김광주;이정민
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.86-93
    • /
    • 1998
  • A permeation apparatus has been devdoped which could make the on-line measurements of both flux and permeate composition. Pervaporative experiment of a single component, i.e. water was performed by using poly(vinyl alcohol) membrane crosslinked with glutaraldehyde to confirm the validity of the apparatus. In the experiment, steady-state permeation was obtained in 15 minutes and the measurement could be completed within 20 minutes. A comparison of the on-line measurement was made with the fluxes measured simultaneously by the conventional method in which the permeates were collected by liquid nitrogen. The on-line measurement by the apparatus showed an excellent agreement with the conventional measurement within a difference of $\pm$2%. From the flux data with operating time, 3 kinds of diffusion coefficients of water $D_{slope}, D_{1/2}$, and $D_t$ were determined, which were also coincident with values in a literature. It was confirmed that accurate measurements of fluxes could be obtained from the apparatus.

  • PDF

Global Fitting Functions for Kinetics of Fe-Selective Chlorination in Ilmenite and Successive Chlorination of Beneficiated TiO2 (일메나이트 중 철의 선택적 염화와 선광된 TiO2의 추가 염화반응에 대한 글로벌 피팅함수)

  • Chung, Dong-Kyu;Won, Yong Sun;Kim, Yong-Ha;Jung, Eun-Jin;Song, Duk-Yong
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.412-424
    • /
    • 2019
  • Global fitting functions for Fe-selective chlorination in ilmenite($FeTiO_2$) and successive chlorination of beneficiated $TiO_2$ are proposed and validated based on a comparison with experimental data collected from the literature. The Fe-selective chlorination reaction is expressed by the unreacted shrinking core model, which covers the diffusion-controlling step of chlorinated Fe gas that escapes through porous materials of beneficiated $TiO_2$ formed by Fe-selective chlorination, and the chemical reaction-controlling step of the surface reaction of unreacted solid ilmenite. The fitting function is applied for both chemical controlling steps of the unreacted shrinking core model. The validation shows that our fitting function is quite effective to fit with experimental data by minimum and maximum values of determination coefficients of $R^2$ as low as 0.9698 and 0.9988, respectively, for operating parameters such as temperature, $Cl_2$ pressure, carbon ratio and particle size that change comprehensively. The global fitting functions proposed in this study are expressed simply as exponential functions of chlorination rate(X) vs. time(t), and each of them are validated by a single equation for various reaction conditions. There is therefore a certain practical merit for the optimal process design and performance analysis for field engineers of chlorination reactions of ilmenite and $TiO_2$.

Public Acceptance of a Health Information Exchange in Korea

  • Park, Hayoung;Park, Jong Son;Lee, Hye Rin;Kim, Soomin
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • Objectives: We assessed the public acceptance of a health information exchange (HIE) and examined factors that influenced the acceptance and associations among constructs of the Technology Acceptance Model (TAM). Methods: We collected data from a survey of 1,000 individuals in Korea, which was administered through a structured questionnaire. We assessed the validity and reliability of the survey instrument with exploratory factor analysis and Cronbach's alpha coefficients. We computed descriptive statistics to assess the acceptance and performed regression analyses with a structural equation model to estimate the magnitude and significance of influences among constructs of TAM. Results: Eighty-seven percent of the respondents were willing to use the technology, and the average level of agreement with the need for the technology was 4.16 on a 5-point Likert scale. The perception of ease of use of the technology significantly influenced perceptions of usefulness and attitudes about the need for HIE. Perceptions of usefulness influenced attitude and behavioral intention to use HIE, and attitude influenced intention. Age showed a wide range of influences throughout the model, and experience with offline-based information exchange and health status also showed noteworthy influences. Conclusions: The public acceptance of HIE was high, and influences posited by TAM were mostly confirmed by the study results. The study findings indicated a need for an education and communication strategy tailored by population age, health status, and prior experience with offline-based exchange to gain public buy-in for a successful introduction of the technology.

An MRI-Based Quantification for Correlation of Imaging Biomarker and Clinical Performance in Chronic Phase of Carbon Monoxide Poisoning

  • Lee, Aleum;Hwang, Ji-sun;Bae, Won-kyung;Park, Jai-soung;Goo, Dong Erk;Park, Sung-Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.241-250
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the relation between quantitative magnetic resonance imaging biomarkers, and clinical performances in chronic phase of carbon monoxide intoxication. Materials and Methods: Eighteen magnetic resonance scans and cognitive evaluations were performed, on patients with carbon monoxide intoxication in chronic phase. Apparent diffusion coefficient (ADC) ratios of affected versus unaffected centrum semiovale, and corpus callosum were obtained. Signal intensity (SI) ratios between affected centrum semiovale, and normal pons in T2-FLAIR (fluid-attenuated inversion recovery) images were obtained. The Mini-Mental State Exam, and clinical outcome scores were assessed. Correlation coefficients were calculated, between MRI and clinical markers. Patients were further classified into poor-outcome and good-outcome groups based on clinical performance, and imaging parameters were compared. T2-SI ratio of centrum semiovale was compared, with that of 18 sex-matched and age-matched controls. Results: T2-SI ratio of centrum semiovale was significantly higher in the poor-outcome group, than that in the good-outcome group and was strongly inversely correlated, with results from the Mini-Mental State Exam. ADC ratios of centrum semiovale were significantly lower in the poor outcome group than in the good outcome group, and were moderately correlated with the Mini-Mental State Exam score. Conclusion: A higher T2-SI and a lower ratio of ADC values in the centrum semiovale, may indicate presence of more severe white matter injury and clinical impairment. T2-SI ratio and ADC values in the centrum semiovale, are useful quantitative imaging biomarkers for correlation with clinical performance in individuals with carbon monoxide intoxication.