• 제목/요약/키워드: differential power analysis

검색결과 420건 처리시간 0.031초

저전력 저잡음 클록 합성기 PLL 설계 (Design of a Low-Power Low-Noise Clock Synthesizer PLL)

  • 박준규;심현철;박종태;유종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.479-481
    • /
    • 2006
  • This paper describes a 2.5V, 320MHz low-noise and low-power Phase Locked Loop(PLL) using a noise-rejected Voltage Controlled ring Oscillator(VCO) fabricated in a TSMC 0.25um CMOS technology. In order to improve the power consumption and oscillation frequency of the PLL, The VCO consist of three-stage fully differential delay cells that can obtain the characteristic of high speed, low power and low phase noise. The VCO operates at 7MHz -670MHz. The oscillator consumes l.58mA from a 320MHz frequency and 2.5V supply. When the PLL with fully-differential ring VCO is locked 320MHz, the jitter and phase noise measured 26ps (rms), 157ps (p-p) and -97.09dB at 100kHz offset. We introduce and analysis the conditions in which ring VCO can oscillate for low-power operation.

  • PDF

Design and Performance Verification of Compound CVTs with 2K-H I type Differential Gear

  • Kim Yeon-Su;Park Jae-Min;Choi Sang-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.770-781
    • /
    • 2006
  • This paper defined design constraints for the compound CVTs (continuously variable trans-missions) by combining power-circulation-mode CVTs and power-split-mode CVTs, which were proposed for connecting 2K-H I-type differential gear to V-belt-type CVU (Continuously Variable Unit). The design constraints are the necessary and sufficient conditions to avoid geometrical interferences among elements in the compound CVTs, and to guarantee smooth assembly between the power-circulation-mode CVT and power-split-mode CVT Two com-pound CVTs were designed and manufactured in accordance with the design constraints. With these compound CVTs, theoretical analysis and performance experiments were conducted. The results showed that the design constraints were valid and effective design method, and that the designed compound CVTs had the improved performance.

차분 전력 분석 공격에 대한 캐리 기반 랜덤 리코딩 방법의 취약성 (Vulnerability of Carry Random Scalar Recoding Method against Differential Power Analysis Attack)

  • 하재철
    • 정보보호학회논문지
    • /
    • 제26권5호
    • /
    • pp.1099-1103
    • /
    • 2016
  • 정보보호용 임베디드 장치에 타원 곡선 암호 알고리듬을 구현할 경우 스칼라 곱셈 연산을 수행하게 되는데 이 연산 과정에서 발생하는 전력 소비 정보에 의해 비밀 키가 노출될 가능성이 있다. 최근에는 비밀 키 값을 리코딩하여 사용함으로써 단일 전력 분석과 차분 전력 분석 공격을 방어할 수 있도록 하는 캐리 랜덤 리코딩 방식이 제안되었다. 본 논문에서는 이 방식을 이용하면 차분 전력 분석을 방어할 수 있다는 원 논문의 주장과 달리 사용하는 리코딩 과정에서 발생하는 캐리 크기의 제한성으로 인해 차분 전력 분석에 여전히 취약함을 밝히고자 한다.

2K-H형 I 형식 차동기어장치와 V-belt 전동장치를 결합한 무단변속기의 개발 (Development of CVTs Composed of a 2K-H I Type Differential Gear Unit and a V-belt Drive)

  • 김연수;최상훈
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1060-1068
    • /
    • 2002
  • Compound continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdrive mode. They are composed of a 2K-H I type differential gear unit, a V-belt type continuously variable unit(CVU), a few friction clutches and gears, and not required of a starting device as a torque converter. Compound CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and efficiency are executed and proven by experimental studies.

차동기어장치를 적용한 입력축 연결방식 무단변속기의 동력흐름 및 효율해석에 관한 연구 (Power Flow and Efficiency of Input Coupled type CVT combined Differential Gear Unit)

  • 김연수;최상훈
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.141-150
    • /
    • 2000
  • Continuously variable transmission(CVT) combined differential gear unit has many advantages, which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. It is known that such CVT can be classified into the input coupled type and the output coupled type according to the coupling location of continuously variable unit(CVU). In this paper, six different configurations of input coupled type CVT combined V-belt CVU and 2K-H I type differential gear unit are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. The propriety of derived formula and theoretical analysis are proven by various experiments.

  • PDF

송전급 초전도한류기의 적용에 따른 선로보호용 비율전류차동계전기의 동작특성 및 보호협조 분석 (Analysis on the Operation Characteristics and Protection Coordination between the Current Ratio Differential Relay for Line Protection and the Trigger-type SFCL in the Power Transmission System)

  • 조용선;김진석;임성훈;김재철
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.925-930
    • /
    • 2013
  • The fault current of the power transmission system is greater than that of the power distribution system. Therefore, the introduction of superconducting fault current limiter (SFCL) is more needed to reduce the increased fault current. The trigger-type SFCL consists of the high-temperature superconducting element (HTSC), the current limiting reactor (CLR) and the circuit breaker (CB). The trigger-type SFCL can be used to supplement the disadvantages of the resistive-type SFCL. The operation characteristics of the current ratio differential relay which is usually applied to the protection device of the power transmission system are expected to be affected under fault conditions and the applicability of the trigger-type SFCL. In this paper, we analyzed the operating characteristics, by the fault conditions, between the current ratio differential relay for line protection and the trigger-type SFCL in the power transmission system through the PSCAD/EMTDC simulation.

2K-HI 형식 복합형 무단변속기의 성능실험 (Performance Analysis of Compound CVTs with a 2K-HI)

  • 박재민;김연수;이상희;최상훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1345-1348
    • /
    • 2005
  • We designed the compound CVT (Continuously Variable Transmissions) by combining power circulation mode CVT and power split mode CVT, which have been proposed for connecting 2K-H I differential gear to the V- belt type CVU (Continuously Variable Unit), as an input coupled type. With the designed compound CVT, we carried out theoretical analysis and performance experiments. We proved that the compound CVT had a better performance than either of the power circulation mode or power split mode.

  • PDF

PSCAD를 이용한 전력용 변압기 모델링과 과도 해석 (Power Transformer Modeling and Transient Analysis using PSCAD)

  • 박철원
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.122-129
    • /
    • 2016
  • Current differential protection relaying with second harmonic restraint is the main protection for large capacity power transformer. PSCAD simulation program is widely used for modeling of dynamic varying transients phenomena. This paper deals with a power transformer model and transients analysis using PSCAD software to develop IED for power transformer. Simulation was carried out using a three phase 40MVA, 154/22.9kV, 60Hz, two-winding transformer with Y-Y connection used in actual fields. The paper analyzed transformer magnetizing inrush, external fault, and internal fault conditions with this model in the time domain. In addition, we performed an analysis in the frequency domain using FFT during several conditions.

콘크리트 믹서 트럭용 믹서 감속기의 차동 유성 기어 트레인에 대한 위험속도 해석 (The Critical Speed Analysis of the Differential Planetary Gear Train of a Concrete Mixer Truck Mixer Reducer)

  • 배명호;배태열;김당주
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2017
  • The power train of a concrete truck mixer reducer includes differential planetary gears to get a large reduction ratio for operating the mixer drum in a compact structure. These differential planetary gears are a very important part of the mixer reducer where strength problems are the main concern. Gear bending stress, gear compressive stress and scoring failure are the main concerns. Many failures in differential planetary gears are due to the insufficient gear strength and resonance problems caused by major excitation forces such as gear mating failure in the transmission. In the present study, where the excitation frequencies are the gear tooth passing frequencies of the mating gears, a Campbell diagram is used to calculate differential planetary gear critical speeds. Mode shapes and natural frequencies of the differential planetary gears are calculated by CATIA V5. These are used to predict gear resonance failures by comparing the working speed range with the critical speeds due to the gear transmission errors of the differential planetary gears.

동력순환형과 동력분류형을 구현 가능한 복합형 무단변속기 (Compound CVT realizing Power Circulation Mode and Power Split Mode)

  • 최상훈;김연수
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.96-103
    • /
    • 2005
  • We designed the compound CVT(Continuously Variable Transmissions) by combining power circulation mode and power split mode, which have been proposed for connecting 2K-H I differential gear to the V- belt type CVU(Continuously Variable Unit), as an input coupled type. With the designed compound CVT, we carried out theoretical analysis and performance experiments for efficiency, speed ratio, power flow, and power transmission ratio. We proved that the compound CVT had a better performance than either of the power circulation mode or power split mode.