• Title/Summary/Keyword: differential detector

Search Result 116, Processing Time 0.025 seconds

Senescent Effects on Color Perception and Emotion

  • Han, Jeong-won;Kim, Bog G.;Choi, Inyoung;Park, Soobeen
    • Architectural research
    • /
    • v.18 no.3
    • /
    • pp.83-90
    • /
    • 2016
  • Senescent effects are the gradual deterioration of function caused by biological aging. Senescent effects on color vision are not clearly understood even after considerable researches. Part of the reason is that the color vision is a complex phenomenon resulting from various factors such as organic systems, and the physical (neuro-optical) and the psychological (experiential) processes of color perception. We performed a field experiment on color perceptional differences due to aging vision. Our experiment was applied to two different groups in South Korea: an experimental group (46 subjects of over the age of 61 years) and a control group (49 subjects in their twenties). The experimental tools are comprised of (1) six gradual yellowing detector board (40%, 50%, 60%, 70%, 80%, 90%); (2) pairs of vivid-strong, vivid-deep, grayish-deep, deep-dull, and bright-light tones of Blue (B) and Purple (P) colors; (3) Red (R), Yellow (Y), Green (G), Blue (B), and Purple (P) colors of dull-tones and pale-tones; and (4) a questionnaire on the semantic differential scales of the color images and color differences. A diagnosis system of gradual yellow vision, developed by the authors for this study, was adapted to generate the color detecting boards. The results are as follows. (1) There are significant differences between the two groups in detecting colors that simulate 40% and 50% of yellow vision. (2) As to the color difference detecting ability between similar tones, the experimental group shows difficulties in pairs of vivid-strong tones and deep-dull tones of the B color. And (3), the emotional responses to the dull tone and the pale tone are not stable in the red, the yellow, blue, and purple. Thus, we empirically demonstrate the specific differences in color perception between the old and young groups.

DEVELOPMENT STATUS OF IRRADIATION DEVICES AND INSTRUMENTATION FOR MATERIAL AND NUCLEAR FUEL IRRADIATION TESTS IN HANARO

  • Kim, Bong-Goo;Sohn, Jae-Min;Choo, Kee-Nam
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.203-210
    • /
    • 2010
  • The $\underline{H}igh$ flux $\underline{A}dvanced$ $\underline{N}eutron$ $\underline{A}pplication$ $\underline{R}eact\underline{O}r$ (HANARO), an open-tank-in-pool type reactor, is one of the multi-purpose research reactors in the world. Since the commencement of HANARO's operations in 1995, a significant number of experimental facilities have been developed and installed at HANARO, and continued efforts to develop more facilities are in progress. Owing to the stable operation of the reactor and its frequent utilization, more experimental facilities are being continuously added to satisfy various fields of study and diverse applications. The irradiation testing equipment for nuclear fuels and materials at HANARO can be classified into capsules and the Fuel Test Loop (FTL). Capsules for irradiation tests of nuclear fuels in HANARO have been developed for use under the dry conditions of the coolant and materials at HANARO and are now successfully utilized to perform irradiation tests. The FTL can be used to conduct irradiation testing of a nuclear fuel under the operating conditions of commercial nuclear power plants. During irradiation tests conducted using these capsules in HANARO, instruments such as the thermocouple, Linear Variable Differential Transformer (LVDT), small heater, Fluence Monitor (F/M) and Self-Powered Neutron Detector (SPND) are used to measure various characteristics of the nuclear fuel and irradiated material. This paper describes not only the status of HANARO and the status and perspective of irradiation devices and instrumentation for carrying out nuclear fuel and material tests in HANARO but also some results from instrumentation during irradiation tests.

Measurement of Energy Dependent Differential Neutron Capture Cross-section of Natural Sm by Using a Continuous Neutron Flux below (연속에너지 중성자에 대한 천연 Sm의 중성자 포획단면적 측정)

  • Yoon, Jungran
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.337-341
    • /
    • 2016
  • We measured the neutron capture cross-section of natural Sm(n,${\gamma}$) reaction in the energy regions from 0.003 to 10 eV. The 46-MeV electron linear accelerator of Research Reactor Institute, Kyoto University was used for generating a continuous neutron source. The neutron time-of-flight method was adopted for energy measurement. An assembly of BGO($Bi_4Ge_3O_{12}$) scintillators composed of 12 pieces of BGO crystals measured prompt gamma rays from Sm(n,${\gamma}$) reaction. The BGO assembly was located at a distance of $12.7{\pm}0.02m$ from the neutron source. In order to determine the neutron flux impinging on the Sm, the $^{10}B(n,{\alpha}{\gamma})^7Li$ standard cross-section were used. Natural Sm(n,${\gamma}$) reaction measurement result of the neutron capture cross-section was compared with the results of evaluation of the BROND-2.2 and the previous experimental data of J. C. Chou and V. N. Kononov.

Analysis of a TC-16ADPSK Performance for Transmitting Different Information on One Channel Simultaneously (TC-16ADPSK을 사용한 이종 정보 동시 전송용 변조방식의 성능 분석)

  • 이원석;강희훈;이성백
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.5
    • /
    • pp.71-76
    • /
    • 2000
  • A TC-16ADPSK scheme for transmitting different kinds of information simultaneously is proposed in this paper. The scheme is designed for simultaneously transmitting two kinds of Information on one channel. In signal mapping, a data of two kinds of information is used to phase modulation on Star-16APSK constellation and the other to amplitude modulation. In detection, each data independently recovers from mixing signal on each detector Therefore, we can transmit two kinds of Information on one channel can be transmitted efficiently. BER performance of the proposed scheme is analyzed on AWGN channel and Rayleigh fading channels on a computer with Matlab communication toolbox. On same SNR, the Gray code mapping has more 0.5-1.5dB coding gains than Ungerboeck's code mapping gains.

  • PDF

Enzymatic synthesis of asymmetric structured lipids containing 1,2-disaturated-3-unsaturated glycerol using acyl migration (효소적 Acyl migration을 이용한 비대칭형 재구성지질(1,2-disaturated-3-unsaturated glycerol)의 합성 및 분석)

  • Hyeon, Jin-Woo;Lee, Ki-Teak
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • The enzymatic interesterification was performed to produce structured lipids (SLs) with palm mid fraction (PMF) and stearic ethyl ester (STEE) for 1, 3, 6, 9, 12 and 15 hr at $80^{\circ}C$. The reaction was catalyzed by Lipozyme TLIM (immobilized lipase from Thermomyces lanuginosus, amount of 20% by weight of total substrates) in a shaking water bath set at 180 rpm. The optimum condition for synthesis of asymmetric SLs were: substrate molar ratio 1:0.5 (PMF:STEE, by weight), reaction time 6 hr, enzyme 20% (wt%, water activity=0.085) of total substrate and reaction temperature $80^{\circ}C$. After reaction at optimized condition, triacylglycerols (symmetrical and asymmetrical TAGs) from reactants were isolated. POP/PPO (1,3-palmitoyl-2-oleoyl glycerol or 1,2-palmitoyl-3-oleoyl glycerol), POS/PSO (palmitoyl-oleoyl-stearoyl glycerol or palmitoyl-stearoyl-oleoyl glycerol), SOS/SSO (1,3-stearoyl-2-oleoyl glycerol or 1,2-stearoyl-3-oleoyl glycerol) were obtained by solvent fractionation. Finally, refined SLs contained stearic acid of 16.91%. Solid fat index and thermogram of the refined SLs were obtained using differential scanning calorimetry. The degree of asymmetric triacylglycerol in the refined SLs was analyzed by Ag-HPLC equipped with evaporated light scattering detector (ELSD). The refined SLs consisted of symmetric TAG of 41.15 area% and asymmetric TAG of 58.85 area%.

Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

  • Park, Sun-Youp;Choi, Jin;Roh, Dong-Goo;Park, Maru;Jo, Jung Hyun;Yim, Hong-Suh;Park, Young-Sik;Bae, Young-Ho;Park, Jang-Hyun;Moon, Hong-Kyu;Choi, Young-Jun;Cho, Sungki;Choi, Eun-Jung
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.221-227
    • /
    • 2016
  • As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

Gain clamping system of erbium-doped fiber amplifier using differential ASE monitoring (WDM용 EDFA의 이득조절 시스템을 구현하기 위한 ASE 차동 감시 방법에 대한 연구)

  • 윤호성;배성호;박재형;박남규;안성준
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2000
  • This paper presents a simple but novel gain deviation detector scheme which can be used for general gain-clamping systems. By using the difference of ASEJprobe powers extracted from the edges of gain-flattened bandwidth, gain deviation of EDFA can be exactly detected regardless of the operating condition of a constructed EDFA. To prove the vahd1ty of the suggested scheme, we Implemented gain clamping systems on a single EDFA and cascaded EDFA's link and achieved sufficient gam-clamping performance without the elaborate measurement for tlIe determination of control parameters. eters.

  • PDF

A PLL Based 32MHz~1GHz Wide Band Clock Generator Circuit for High Speed Microprocessors (PLL을 이용한 고속 마이크로프로세서용 32MHz~1GHz 광대역 클럭발생회로)

  • Kim, Sang-Kyu;Lee, Jae-Hyung;Lee, Soo-Hyung;Chung, Kang-Min
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.1
    • /
    • pp.235-244
    • /
    • 2000
  • This paper presents a low power PLL based clock geneator circuit for microprocessors. It generates 32MHz${\sim}$1GHz clocks and can be integrated inside microprocessor chips. A high speed D Flip-Flop is designed using dynamic differential latch and a new Phase Frequency Detector(PFD) based on this FF is presented. The PFD enjoys low error characteristics in phase sensitivity and the PLL using this PFD has a low phase error. To improve the linearity of voltage controlled oscillator(VCO) in PLL, the voltage to current converter and current controlled oscillator combination is suggested. The resulting PLL provides wide lock range and extends frequency of generated clocks over 1 GHz. The clock generator is designed by using $0.65\;{\mu}m$ CMOS full custom technology and operates with $11\;{\mu}s$ lock-in time. The power consumption is less than 20mW.

  • PDF

Preliminary study on car detection and tracking method using surveillance camera in tunnel environment for accident detection (터널 내 유고상황 자동 판정을 위한 선행 연구: CCTV를 이용한 차량의 탐지와 추적 기법 고찰)

  • Oh, Young-Sup;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.813-827
    • /
    • 2017
  • Surveillance cameras installed in tunnels capture the various video frames effected by dynamic and variable factors. In addition, localizing and managing the cameras in tunnel is not affordable, and quality of capturing frame is effected by time. In this paper, we introduce a new method to detect and track the vehicles in tunnel by using surveillance cameras installed in a tunnel. It is difficult to detect the video frames directly from surveillance cameras due to the motion blur effect and blurring effect on lens by dirt. In order to overcome this difficulties, two new methods such as Differential Frame/Non-Maxima Suppression (DFNMS) and Haar Cascade Detector to track cars are proposed and investigated for their feasibilities. In the study, it was shown that high precision and recall values could be achieved by the two methods, which then be capable of providing practical data and key information to an automatic accident detection system in tunnels.

Clinical and radiographic features of facial cosmetic materials: A systematic review

  • Alsufyani, Noura;Aldosary, Reem;Alrasheed, Rasha;Alsufyani, Mohammed
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.155-164
    • /
    • 2022
  • Purpose: The aim of this study was to systematically screen the literature for studies reporting cosmetic material in the oral and maxillofacial complex to shed light on the types of cosmetic materials, their radiographic appearance, and possible complications. Materials and Methods: Five electronic databases were reviewed for eligible studies. The general search terms were "cosmetic," "filler," "face," and "radiograph." Demographics, material types, clinical and radiographic presentation, and complications were recorded. Results: Thirty-one studies with 53 cases met the inclusion criteria. The mean age was 52.6±15.4 years with a 4 : 3 female-to-male ratio. The most common material was calcium hydroxyapatite (CaHa) (n=14, 26.4%), found incidentally. The materials were generally located within the upper cheek and zygoma (n=35, 66.0%), radiographically well-defined (n=44, 83%), and had no effects on the surrounding structures (n=27, 50.9%). The internal structure was radiopaque (calcification, hyperdensity) for gold wires, CaHa, bone implants, and secondary calcification or ossification. Outdated cosmetic materials or non-conservative techniques were infiltrative, had effects on the surrounding structures, and presented with clinical signs, symptoms, or complications. Conclusion: Conventional radiography, cone-beam computed tomography, and multi-detector computed tomography are useful to differentiate several cosmetic materials. Their magnetic resonance imaging appearance was highly variable. The infrequent inclusion of cosmetic materials in the differential diagnosis implies that medical and dental specialists may be unfamiliar with the radiographic appearance of these materials in the face.