• Title/Summary/Keyword: differential detection

Search Result 564, Processing Time 0.06 seconds

Characterization of a Peptide Antibody Specific to the Adenylyl Cyclase-Associated Protein of Acanthamoeba castellanii

  • Kim, Min-Jeong;Lee, Hae-Ahm;Quan, Fu-Shi;Kong, Hyun-Hee;Moon, Eun-Kyung
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.1
    • /
    • pp.7-14
    • /
    • 2022
  • Acanthamoeba keratitis (AK) is a rare infectious disease and accurate diagnosis has remained arduous as clinical manifestations of AK were similar to keratitis of viral, bacterial, or fungal origins. In this study, we described the production of a polyclonal peptide antibody against the adenylyl cyclase-associated protein (ACAP) of A. castellanii, and evaluated its differential diagnostic potential. Enzyme-linked immunosorbent assay revealed high titers of A. castellanii-specific IgG and IgA antibodies being present in low dilutions of immunized rabbit serum. Western blot analysis revealed that the ACAP antibody specifically interacted with A. castellanii, while not interacting with human corneal epithelial (HCE) cells and other causes of keratitis such as Fusarium solani, Pseudomonas aeruginosa, and Staphylococcus aureus. Immunocytochemistry (ICC) results confirmed the specific detection of trophozoites and cysts of A. castellanii co-cultured with HCE cells. The ACAP antibody also specifically interacted with the trophozoites and cysts of 5 other Acanthamoeba species. These results indicate that the ACAP antibody of A. castellanii can specifically detect multiple AK-causing members belonging to the genus Acanthamoeba and may be useful for differentially diagnosing Acanthamoeba infections.

Nondestructive Evaluation of Residual Life of 1Cr-1Mo-0.25V Steel by Reversible Magnetic Permeability

  • K. S. Ryu;S. H. Nahm;Kim, Y. I.;K. M. Yu;Kim, Y. B.;Y. Cho;D. Son
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.522-529
    • /
    • 2000
  • We present a new procedure to evaluate the residual life of 1Cr-1Mo-0.25V steel by reversible magnetic permeability. The method is based on the existence of the first harmonics in the differential magnetization around the coercive force. The apparatus is based on the detection of the voltage induced in a coil using a lock-in amplifier tuned to a frequency of the exciting one. Results obtained for the first harmonics and Vickers hardness on the aged samples show that the peak interval of reversible permeability and Vickers hardness decrease as ageing time increases. The correlation between Vickers hardness and the peak interval of the reversible permeability could well be used to evaluate the residual life of 1Cr-1Mo-0.25V steel, nondestructively.

  • PDF

Recent Updates on PET Imaging in Neurodegenerative Diseases (퇴행성 뇌질환에서 PET의 발전과 임상적 적용 및 최신 동향)

  • Yu Kyeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.453-472
    • /
    • 2022
  • Over the past decades, the immense clinical need for early detection methods and treatments for dementia has become a priority worldwide. The advances in PET biomarkers play increasingly important roles in understanding disease mechanisms by demonstrating the protein pathology underlying dementia in the brain. Amyloid-β and tau deposition in PET images are now key diagnostic biomarkers for the Alzheimer's disease continuum. The inclusion of biomarkers in the diagnostic criteria has achieved a paradigm shift in facilitating early differential diagnosis, predicting disease prognosis, and influencing clinical management. Furthermore, in vivo images showing pathology could become prognostic as well as surrogate biomarkers in therapeutic trials. In this review, we focus on recent developments in radiotracers for amyloid-β and tau PET imaging in Alzheimer's disease and other neurodegenerative diseases. Further, we introduce their potential application as future perspectives.

Atypical presentation of DeBakey type I aortic dissection mimicking pulmonary embolism in a pregnant patient: a case report

  • Sou Hyun Lee;Ji Hee Hong;Chaeeun Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.128-133
    • /
    • 2024
  • Aortic dissection in pregnant patients results in an inpatient mortality rate of 8.6%. Owing to the pronounced mortality rate and speed at which aortic dissections progress, efficient early detection methods are crucial. Here, we highlight the importance of early chest computed tomography (CT) for differentiating aortic dissection from pulmonary embolism in pregnant patients with dyspnea. We present the unique case of a 38-year-old pregnant woman with elevated D-dimer and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels, initially suspected of having a pulmonary embolism. Initial transthoracic echocardiography did not indicate aortic dissection. Surprisingly, after an emergency cesarean section, a chest CT scan revealed a DeBakey type I aortic dissection, indicating a diagnostic error. Our findings emphasize the need for early chest CT in pregnant patients with dyspnea and elevated D-dimer and NT-proBNP levels. This case report highlights the critical importance of considering both aortic dissection and pulmonary embolism in the differential diagnosis of such cases, which will inform future clinical practice.

A Coherent-based Symbol Detector for 2.45GHz LR-WPAN Receiver (2.45GHz LR-WPAN 수신기를 위한 Coherent 기반의 Symbol Detector)

  • Han Jung-Su;Do Joo-Hyun;Park Tha-Joon;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2A
    • /
    • pp.176-186
    • /
    • 2006
  • In this paper, we propose an enhanced symbol detector algorithm for 2.45GHz LR-WPAN(Low-Rate Wireless Personal Area Network) receiver. Because the frequency offset of $\pm$80ppm on 2.45GHz band is recommended in IEEE 802.15.4 LR-WPAN(Low-Rate Wireless Personal Area Network) specification, a symbol detector algorithm having stable operation in the channel environment with large frequency offset is required. For robustness to the frequency offset, non-coherent detection-based symbol detector algorithm is typically applied in the LR-WPAN receiver modem. However, the noncoherent symbol detector has increased performance degradation and hardware complexity due to squaring loss of I/Q squaring operation. Therefore we propose a coherent detection-based symbol detector algorithm with frequency offset compensation using a preamble symbol. The proposed algorithm is more suitable for LR-WPAN receiver aimed at low-cost, low-power and low-complexity than the non-coherent symbol detector, since it can reduce performance degradation due to squaring loss of I/Q squaring operation and implementation complexity. Simulation results show that the proposed algorithm has performance improvement of about 1dB in various channel environments.

Estimation of the Central Aortic Pulse using Transfer Function and Improvement of an Augmentation Point Detection Algorithm (전달함수를 이용한 대동맥 맥파 추정 및 증강점 검출 알고리즘 개선에 관한 연구)

  • Im, Jae-Joong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.68-79
    • /
    • 2008
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness quantitatively and even to evaluate ventricular load. However, in order to calculate aortic AIx catheters should be inserted to the subjects' artery, which hampers its clinical usage. To overcome such limitation, aortic AIx has been indirectly calculated by estimating aortic pressure wave from the peripheral arterial pulse by applying transfer functions. In this study, central aortic pressure waves using Millar catheter and radial artery pulse waves using tonometry pressure sensor were measured to establish transfer functions for an estimation of central aortic pressure waves from radial artery pulse waves. Also, an algorithm which detects augmentation point for the calculation of AIx were developed. Developed algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Transfer functions were established using 10th order ARX model and were verified for the stability of the transfer function through residual analysis. Evaluation of an algorithm for the detection of augmentation point were performed by comparing the augmentation points obtained from developed algorithm with the known augmentation points synthesized in various conditions. In addition, developed algorithm for the AIx is proved to provide more accurate results than the ones developed by previous studies. The significance of the study was in two folds. Firstly, the results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and secondly, extension of the study may enable the early diagnosis of various vascular diseases.

Noisy OTDR Data Event Detection Analysis for the Real Time Optical Fiber Link Monitoring (실시간 광선로망 감시를 위한 Noisy OTDR 신호 분석 방법)

  • Ko, Dae-Young;Baek, Sung-June;Park, Aaron;Kim, Jin-Bong;Nah, Yong-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.122-128
    • /
    • 2016
  • This paper, proposes a new analysis method for the event detection of an OTDR signal. An OTDR signal was passed through the Hamming filter to remove the high frequency noise included in the signal. The signal was then passed consecutively through a differential filter to detect the events of interest. The terminal position was determined using the fact that there is a large gap between the signal and the trailing noise power beyond the terminal. This study examined the local maxima of the signal up to the terminal position and determined the peak regions. The real events were determined from the peak regions using noise information and peak threshold. Finally, the user events were found by inspecting the user peaks beyond the terminal position. The events of the OTDR signal without users are located at less than 17m compared to the optical fiber link setup. The events of the JDSU device are located less than 25m and their users are less than 5m. For the RadianTech device, the events are detected at less than 19m and the users are found in 5m. The results suggest that the proposed method is sufficiently applicable to an optical fiber link monitoring system.

Blood Biomarkers for Alzheimer's Dementia Diagnosis (알츠하이머성 치매에서 혈액 진단을 위한 바이오마커)

  • Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.249-255
    • /
    • 2022
  • Alzheimer's disease (AD) represents a major public health concern and has been identified as a research priority. Clinical research evidence supports that the core cerebrospinal fluid (CSF) biomarkers for AD, including amyloid-β (Aβ42), total tau (T-tau), and phosphorylated tau (P-tau), reflect key elements of AD pathophysiology. Nevertheless, advances in the clinical identification of new indicators will be critical not only for the discovery of sensitive, specific, and reliable biomarkers of preclinical AD pathology, but also for the development of tests that facilitate the early detection and differential diagnosis of dementia and disease progression monitoring. The early detection of AD in its presymptomatic stages would represent a great opportunity for earlier therapeutic intervention. The chance of successful treatment would be increased since interventions would be performed before extensive synaptic damage and neuronal loss would have occurred. In this study, the importance of developing an early diagnostic method using cognitive decline biomarkers that can discriminate between normal, mild cognitive impairment (MCI), and AD preclinical stages has been emphasized.

Computer vision-based remote displacement monitoring system for in-situ bridge bearings robust to large displacement induced by temperature change

  • Kim, Byunghyun;Lee, Junhwa;Sim, Sung-Han;Cho, Soojin;Park, Byung Ho
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.521-535
    • /
    • 2022
  • Efficient management of deteriorating civil infrastructure is one of the most important research topics in many developed countries. In particular, the remote displacement measurement of bridges using linear variable differential transformers, global positioning systems, laser Doppler vibrometers, and computer vision technologies has been attempted extensively. This paper proposes a remote displacement measurement system using closed-circuit televisions (CCTVs) and a computer-vision-based method for in-situ bridge bearings having relatively large displacement due to temperature change in long term. The hardware of the system is composed of a reference target for displacement measurement, a CCTV to capture target images, a gateway to transmit images via a mobile network, and a central server to store and process transmitted images. The usage of CCTV capable of night vision capture and wireless data communication enable long-term 24-hour monitoring on wide range of bridge area. The computer vision algorithm to estimate displacement from the images involves image preprocessing for enhancing the circular features of the target, circular Hough transformation for detecting circles on the target in the whole field-of-view (FOV), and homography transformation for converting the movement of the target in the images into an actual expansion displacement. The simple target design and robust circle detection algorithm help to measure displacement using target images where the targets are far apart from each other. The proposed system is installed at the Tancheon Overpass located in Seoul, and field experiments are performed to evaluate the accuracy of circle detection and displacement measurements. The circle detection accuracy is evaluated using 28,542 images captured from 71 CCTVs installed at the testbed, and only 48 images (0.168%) fail to detect the circles on the target because of subpar imaging conditions. The accuracy of displacement measurement is evaluated using images captured for 17 days from three CCTVs; the average and root-mean-square errors are 0.10 and 0.131 mm, respectively, compared with a similar displacement measurement. The long-term operation of the system, as evaluated using 8-month data, shows high accuracy and stability of the proposed system.

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.