• 제목/요약/키워드: different admixtures

검색결과 104건 처리시간 0.028초

수중 콘크리트 구조물을 위한 광물질 혼화제를 첨가한 수중불분리성 콘크리트의 특성 (Characteristics of Antiwashout Underwater Concrete with the Mineral Admixtures for Underwater Concrete Structures)

  • 원종필;임경하;박찬기;김완영
    • 한국농공학회지
    • /
    • 제44권6호
    • /
    • pp.90-98
    • /
    • 2002
  • Recently the use of the antiwashout underwater concrete with the antiwashout admixture is increased considerably. Antiwashout underwater concrete is quite different in concept from conventional underwater concrete. By mixing an antiwashout admixture with concrete, the viscosity of the concrete is increased and its resistance to segregation under the washing action of water is enhanced. The aim of this research is to evaluate the fundamental characteristics and permeability of antiwashout underwater concrete with fly ash and blast-furnace slag. Test Results of antiwashout underwater concrete with fly ash and blast-furnace slag fluence can provide its excellent fundamental characteristics and resistance of permeability.

고인성 섬유복합재료 ECC (Engineered Cementitious Composite)의 시공성 (Processibility of High Ductile Fiber-Reinforced ECCs (Engineered Cementitious Composites))

  • 김윤용;김정수;김진근;하기주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.313-316
    • /
    • 2005
  • In the recent design of high ductile fiber-reinforced cementitious composite ECC, which exhibits tensile strain-hardening behavior in the hardened state, optimizing both processing mechanical properties for specific applications is critical. This study introduced a method to develop useful ECCs in field, which possess the different fluid properties to facilitate diverse types of processing (i.e., self-consolidating or spray processing). Control of rheological modulation was regarded as a key factor to allow the performance of the desired processing, while retaining the ductile material properties. To control the rheological properties of the composite, we first determined basic ECC compositon, which is based on micromechanics and steady-state cracking theory. The stability and consequent viscosity of suspensions were, then, mediated by optimizing dosages of chemical and mineral admixtures. The rheological properties altered by this approach were revealed to be effective in obtaining ECC hardened properties, allowing us to readily achieve the desired function of the fresh ECC.

  • PDF

An Experimental Study on Shear Strength of Chemically-Based Self-Consolidating Concrete

  • Arezoumandi, Mahdi;Volz, Jeffery S.
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권4호
    • /
    • pp.273-285
    • /
    • 2013
  • An experimental investigation was conducted to compare the shear strength of full-scale beams constructed with chemically-based, self-consolidating concrete (SCC) with conventional concrete (CC). This experimental program consisted of 16 rectangular beams (12 without shear reinforcing and 4 with shear reinforcing in the form of stirrups), 8 beams for each mix design. Additionally, three different longitudinal reinforcement ratios were evaluated within the test matrix. The beam specimens were tested under a simply supported four-point condition. The experimental shear strengths of the beams were compared with both the shear provisions of selected standards (U.S., Australia, Canada, Europe, and Japan) and a shear database of CC specimens. This comparison indicates that chemically-based SCC beams possess comparable shear strength as CC beams.

부식 모니터링을 이용한 콘크리트 내의 임계 염화물량 평가 (Estimation of Critical Chloride Threshold Value Using Corrosion Monitoring)

  • 배수호;이광명;정영수;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.801-804
    • /
    • 2004
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mixture proportions, cement type and constituents, presence of admixtures, environmental factors, steel reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and sea water-circulated method, respectively and during the test, corrosion monitoring by half cell potential method was carried out to estimate the critical chloride threshold value when corrosion for reinforcing steel in concrete was perceived. For this purpose, lollypop and beam test specimens were made for $31.4\%,\;41.5\%\;and\;49.7\%$ of w/c. respectively and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with water-cement ratio and the critical chloride threshold value was found to range from 0.91 to $1.27kg/m^3$.

  • PDF

혼화재의 종류에 따른 고강도 콘크리트의 폭렬특성에 관한 실험적 연구 (An experimental Study on explosion property of high-strength concrete according to the kinds of admixtures)

  • 민세홍;권기석;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2013
  • The construction of modern society, the use of high-strength concrete structures is becoming frequent. Admixture has been reported as a factor causing the explosion occurred. This study was experimental research on high strength concrete according to the kinds of admixture. Admixture of four different mix. fire resistance test results are outstanding when using blast furnace slag aggregate. When using silica fume spalling phenomena were most violent.

  • PDF

양생 조건에 따른 콘크리트의 체적 변화 (Volumetric Change of Concrete Subjected to Different Curing Condition)

  • 이광명;이회근;이성진;백빈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.132-135
    • /
    • 2004
  • High-performance concrete (HPC) may be expected to differ from usual concrete with respect to shrinkage behavior, and it shows high autogenous shrinkage due to the use of very low water-binder ratio (w/b) and various admixtures. Therefore, in order to minimize the shrinkage stress and to ensure the service life of concrete structure, volumetric change of HPC should be understood. In this study, small prisms made of HPC with w/b of 0.32 and blast-furnace slag content of $0\%,\;30\%,\;and\;50\%$ were prepared to measure the volumetric changes such as autogenous shrinkage, drying shrinkage, and swelling under three different curing conditions. It was observed that the concrete cured. sealed condition showed only autogenous shrinkage while the concrete let to dry condition at temperature of $20^{\circ}C$ and relative humidity of $60\%$ during the test period showed both autogenous and drying shrinkage. Moreover, the concrete exposed to dry condition after 2-day water curing swelled and then started to shrink with age. The total shrinkage (autogenous+drying) of this concrete was smaller than that of the concrete cured dry condition, especially at early-age. Therefore, the early-age moisture curing is very effective to control or minimize the volumetric change and its induced stress of HPC.

  • PDF

Cavitation resistance of concrete containing different material properties

  • Kumar, G.B. Ramesh;Bhardwaj, Arjit;Sharma, Umesh Kumar
    • Advances in concrete construction
    • /
    • 제6권1호
    • /
    • pp.15-28
    • /
    • 2018
  • In the present investigation, influence of various material parameters on the cavitation erosion resistance of concrete was investigated on the basis of laboratory experiments. As there is no well-established laboratory test method for evaluating the cavitation resistance of concrete, a test set up called 'cavitation jet' was specially established in the present study in order to simulate the cavitation phenomenon experienced in the hydraulic structures. Various mixtures of concrete were designed by varying the grade of concrete, type and quantity of pozzolana, type of aggregates and cement type to develop good cavitation resistant concrete constructed using marginal aggregates. Three types of aggregates having three different Los Angeles abrasion values (less than 30%, between 30% and 50% and more than 50%) were employed in this study. To evaluate the cavitation resistance a total of 60 cylindrical specimens and 60 companion cubes were tested in the laboratory respectively. The results indicate that cavitation resistance of concrete degrades significantly as the L.A. abrasion value of aggregates goes beyond the 30% value. Incorporation of pozzolanic admixtures was seemed to be beneficial to enhance the cavitation resistance of concrete. Influence of other material parameters on the cavitation resistance of concrete was also noted and important observations have been made in the paper.

Performance of High Strength Self-Compacting Concrete Beams under Different Modes of Failure

  • Harkouss, Raya Hassan;Hamad, Bilal Salim
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.69-88
    • /
    • 2015
  • Self-consolidating concrete (SCC) is a stable and cohesive high consistency concrete mix with enhanced filling ability properties that reduce the need for mechanical compaction. Limited standards and specifications have been reported in the literature on the structural behavior of reinforced self-compacting concrete elements. The significance of the research presented in this paper stems from the need to investigate the effect of enhanced fluidity of SCC on the structural behavior of high strength self-consolidating reinforced concrete beams. To meet the objectives of this research, twelve reinforced concrete beams were prepared with two different generations of superplasticizers and designed to exhibit flexure, shear, or bond splitting failure. The compared beams were identical except for the type of superplasticizer being used (second generation sulphonated-based superplasticizer or third generation polycarboxylate-based superplasticizer). The outcomes of the experimental work revealed comparable resistance of beam specimens made with self-compacting (SCC) and conventional vibrated concrete (VC). The dissimilarities in the experimental values between the SCC and the control VC beams were not major, leading to the conclusion that the high flowability of SCC has little effect on the flexural, shear and bond strengths of concrete members.

A Study on the High-Flowing Concrete with Low Unit Weight of Cement

  • Si Woo Lee;Hong Shik Choi;Sang Chel Kim;Gweon Heo
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.318-321
    • /
    • 2000
  • Most compressive strengths commonly used in the construction field are in a range of 240 to 300 kgf/$\textrm{cm}^2$ at 28 days. To get this rage of strengths, however, high-flowing concrete requires cementitious binders more than 400 to 450 kg/$\textrm{cm}^2$ for preventing segregation and sedimentation of aggregates. This amount of cementitious binder generates a large emission of excessive hydration heat, which may consequently induce harmful cracks in concrete structure. In order to reduce excessive hydration heat, thus, this paper aims at fabricating a high-flowing concrete under the condition that cement content is kept as low as 350kg/$\textrm{cm}^3$ by using viscose agents. In a parametric study, effects of cement types such as a ternary blended cement and Type V on he physical characteristics of high-flowing concrete were evaluated. In addition, the influence of viscosity was also investigated by applying two different viscose agents, one in a range of 6,000 to 10,000 cps and the others of 10,000 to 14,000 cps. In terms of chemical admixtures used in concrete mixture, the superplasticizer was Sulfonated Melamine-Formaldehyde Condensate with about 30,000 of molecular weight, and main component of viscose agent was HPMC (Hydroxy Propyl Methyl Cellulose). Slump flow was fixed at 50cm with different dosages of superplasticizer in weight.

  • PDF

멜라민계 고유동화제의 다양한 조건에서의 합성 및 응용 (Synthesis and Application of Melamine-Type Superplasticizer at the Different Synthetic Conditions)

  • 윤성원;신경호;노재성
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.811-818
    • /
    • 2005
  • 플래쉬 콘크리트의 유동성 및 유동성 감소는 유기 화학혼화제의 종류에 영향을 받는다는 것은 잘 알려져 있다. 유기화학 혼화제는 콘크리트의 물성을 증가시킬 수 있다. 술포네이트 나프탈렌 포름알데하이드(SNF, Sulfonated Naphthalene-Formaldehyde) 고유동화제(superplasticizer)가 대표적으로 많이 사용되고 있으나, 유동성 감소의 문제점이 있다. 본 연구에서는 술포네이트 멜라민 포름알데하이드(SFM, Sulfonated Melamine-Formaldehyde) 고유동화제를 합성하여 SNF 고유동화제의 물리적 특성을 보완하고자 한다. SNF계 고유동화제를 4단계로 나누어 반응을 진행하였고, Step.1은 hyydroxymethylation 단계이고, Step.2는 sulfonation단계이고, Step.3은 중합단계이고, Step.4는 안정화 단계이다. SMF 고유동화제의 합성은 pH, 반응온도 및 반응시간에 영향을 받는다 본 합성에서 우리는 멜라민과 포름알데하이드의 몰비를 1:3, 1:4로 변화시키고, Step. 3에서 촉매의 양을 조절하면서 반응을 진행하였다. 그리고, SMF 고유동화제 및 SNF계 고유동화제와 혼합한 시료에 대해서 시멘트 대비 0.5, 1.0, 1.5wt% 첨가하여 물리적 특성을 비교하였다. 고유동화제를 첨가한 시료는 첨가하지 않은 시료 CEM보다 높은 압축강도, 슬럼프 값을 나타내었고, 미세한 기공과 낮은 기공율을 보였다.