• Title/Summary/Keyword: differences in temperature and humidity

Search Result 274, Processing Time 0.027 seconds

Assessment of Bacterial and Fungal Aerosols in the Kitchens of Restaurants (일부 음식점 주방의 부유세균 및 부유진균 조사연구)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Objectives: The purpose of this study was to determine airborne bioaerosols such as bacteria and fungi in the kitchens of restaurants, and to assess the effects of thermal factors on the levels of the bioaerosols. Methods: Air samples were taken from kitchens of nine restaurants. An Anderson type air sampler was used for sampling and measurements. Petri dishes filled with a microbiological culture medium (trypticase soy agar for bacteria and Sabouraud dextrose agar for fungi) were used as the sampling surface. Results: The levels of bacterial aerosol measured were $10-10^3CFU/m^3$ and fungal aerosol $10-10^2CFU/m^3$, respectively The mean values of air temperature and relative humidity in the kitchens were $24.6^{\circ}C$ and 46.4%, respectively. Overall, the levels of bacterial aerosol varied by the restaurant type, and fungal aerosol by the business period (p < 0.05). The main effect of air temperature and interaction effect of air temperature and relative humidity onto the bacterial level were significant (p < 0.05), whereas the effects were not significant onto the fungal level. Conclusions: The results indicate a wide variation in the levels of bioaerosols among different kitchens. The observed differences in bioaerosol levels in the kitchens reflect different periods of use. The interactions of air temperature and relative humidity onto the bacterial level suggest that constant attention should be paid to avoid peaks of contamination during the summer season.

Effect of Thermal Diffusion on Autumn Traffic in Street Space (가을철 교통조건에 따른 가로공간 열확산 분포 영향)

  • Yoon, Yong-Han;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.467-481
    • /
    • 2017
  • This study sought to determine the changes in weather conditions in urban streets, along with conditions of traffic and roads in urban areas. The variations in weather conditions depending on traffic differed according to distance. First, the temperature difference measured by traffic results is as follows: T1 point $1.03^{\circ}C$, T2 point $1.04^{\circ}C$, T3 point $0.9^{\circ}C$, T4 point $1.01^{\circ}C$, and T5 point $0.31^{\circ}C$. The average difference between the measured temperatures by the point of measurement was $0.86^{\circ}C$. The changes in wind velocity according to traffic volume results of the measurements is T1 point 1.32 m/s, T2 point 0.80 m/s, T3 point 0.29 m/s, T4 point 0.04 m/s, and T5 point 0.09 m/s. The difference between the average wind speeds was 0.51 m/s and traffic jams caused substantial differences in distance. The relative humidity tended to be inversely proportional to temperature. The measurements results ares T1 point 2.29%, T2 point 2.67%, T3 point 2.47%, T4 point 2.16%, and T5 point 0.91% The difference between the average relative humidity was 7.3%. In case of independent sampling T test according to traffic volume, changes in wind velocity and temperature were directly proportional to the level of statistical significance(p<0.01). On the other hand, relative humidity tended to be inversely proportional; however, there was no statistical significance.

Physiological Responses and subjective sensations of the human wearing three different materials of Taekwondo wears (태권도복 소재별 인체생리반응과 주관적 감각에 관한 연구)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.582-590
    • /
    • 2004
  • The purpose of this study was to evaluate thermal properties of Taekwondo wears with three different materials. As a begging step, the questionnaire survey about the actual condition of Taekwondo wears was conducted. With the results of the questionnaire, cotton/nylon(70/30) blended fabric(CN) that was newly woven with sweat absorbent finishing and cotton/spandex(95/5) blended fabric with flexibility property were developed. The same designed 3 Taekwondo wears with 3 different materials which were two different materials(CN and CS) and a current material(cotton/PET, CP) were made. Four young males volunteered for this study, they kicked and punched as Taekwondo action for 20 minutes. Mean skin temperature was the highest in CS(33.1${\pm}$0.8$^{\circ}C$) and the lowest in CP(32.7${\pm}$0.6$^{\circ}C$). Increasing degree of rectal temperature didn't show any significant difference. Clothing microclimate temperature on the thigh was higher in CS(32.8${\pm}$17.4$^{\circ}C$) than in CN(29.4${\pm}$1.1$^{\circ}C$) and CP(29.4${\pm}$1.0$^{\circ}C$). Clothing microclimate temperature on the back and humidity on the thigh didn't show any significant differences. Clothing microclimate humidity on the back was higher in CP(65${\pm}$20%RH) than in CS(61${\pm}$17%RH). Heart rate, total body weight loss, and local sweating were not significantly different by materials. Most subject responded more hot in CN than in others, but there were no significant differences at the subjective sensation of thermal humidity. They answered more comfortable in CN than in others. Tectile sensations were the best in CN and the worst in CS. From those results, first of all, it is necessary to be weighted on Taekwondo wears made of CN in the aspects of the dignity of military arts uniform. Secondly, CS was required to be lighted and enhanced for the subjective sensation. Third, CP weaved honey comb was asked more various design to eliminate sweat high competition power within the scope of the dignity of military arts uniform.

A Study on Nocturnal Inversion at Urban Area in Winter (동절기 도심지 야간 기온역전에 관한 연구)

  • Zheng, Hai-Yan;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • In urban area, inversion layer prevents air pollutants from being dispersed. To determine nocturnal inversion characteristics at SookMyung Girls' High School near high-rise residential commercial complex buildings in Seoul, air temperature and humidity data were observed at 10minute interval from December 1st, 2007 to May 2nd, 2008. Temperature-Humidity (T-H) sensors were installed at SMG (SookMyung_Ground) and SMR (SookMyung_Roof), and then these two data were compared, analyzed and examined to illustrate air temperature differences of SMG and SMR. After the analysis, the maximum nocturnal inversion was observed by $3.3^{\circ}C$ at 18:10 on December 26th 2007, at that time the weather condition was clear and weak wind. Nocturnal inversions began 2-3 hours before sunset and it reached maximum inversion just after sunset and continued through nighttime until sunrise or 1-2 hours after sunrise. In terms of seasonal variation nocturnal inversions occurred dominantly in March and April rather than winter season.

Effects of heat stress on conception in Holstein and Jersey cattle and oocyte maturation in vitro

  • Jihwan Lee;Doosan Kim;Junkyu Son;Donghyeon Kim;Eunjeong Jeon;Dajinsol Jung;Manhye Han;Seungmin Ha;Seongsoo Hwang;Inchul Choi
    • Journal of Animal Science and Technology
    • /
    • v.65 no.2
    • /
    • pp.324-335
    • /
    • 2023
  • Korea, located in East Asia in the northern hemisphere, is experiencing severe climate changes. Specifically, the heat stress caused by global warming is negatively affecting the dairy sector, including milk production and reproductive performance, as the major dairy cattle Holstein-Friesian is particularly susceptible to heat stress. Here, we collected artificial insemination and pregnancy data of the Holstein and the Jersey cows from a dairy farm from 2014 to 2021 and analyzed the association between the conception rate and the temperature-humidity index, calculated using the data from the closest official weather station. As the temperature-humidity index threshold increased, the conception rate gradually decreased. However, this decrease was steeper in the Holstein breed than in the Jersey one at a temperature-humidity index threshold of 75. To evaluate the effects of heat stress on the oocyte quality, we examined the nuclear and cytoplasmic maturation of Holstein (n = 158, obtained from six animals) and Jersey oocytes (n = 123, obtained from six animals), obtained by ovum pick-up. There were no differences in the nuclear maturation between the different conditions (heat stress: 40.5℃, non- heat stress: 37.5℃) or breeds, although the Holstein oocytes seemed to have a lower metaphase II development (p = 0.0521) after in vitro maturation under heat stress conditions. However, we found that the Holstein metaphase II oocytes exposed to heat stress presented more reactive oxygen species and a peripheral distribution of the mitochondria, compared to those of the Jersey cattle. Here, we show that weather information from local meteorological stations can be used to calculate the temperature-humidity index threshold at which heat stress influences the conception rate, and that the Jersey cows are more tolerant to heat stress in terms of their conception rate at a temperature-humidity index over 75. The lower fertility of the Holstein cows is likely attributed to impaired cytoplasmic maturation induced by heat stress. Thus, the Jersey cows can be a good breed for the sustainability of dairy farms for addressing climate changes in South Korea, as they are more resistant to hyperthermia.

Thermal Properties on combination of Velvet and Lining (벨벳과 안감의 소재 조합에 따른 의복의 열저항에 관한 연구)

  • 계명대학교의류학과;이욱자;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.3-13
    • /
    • 1999
  • This study was performed for purpose of getting fundamental information requisite to wear velvet clothes that is more comfortable for the human body and also the environment. It was carried out in a human wearing test and thermal manikin test at the same time in a controlled-condition chamber. The experimental environment had a ambient temperature of 15$\pm$0.5$^{\circ}C$ with the relative humidity at 5$^{\circ}C$$\pm$5% and with air velocity at less that than 0.2m/sec. Velvet differ from common plain weaves in thermal properties because it's constructed in two parts one is ground part and the other part is pile part. In order to investigate the thermal resistance of velvet eight different combination of 4 velvet kinds and 2 lings kinds as experimental clothes. [(4 velvet kinds : Acetate cuprammoium Rayon Cotton Wool) (2 lining kinds : acetate viscose rayon)longrightarrow8 combination: Aa, Av, Ra, Rv, Ca, Cv, Wa, Wv: the simplified character] The results of this study can be summarized as follows : 1. For the regional thermal resistance the differences in eight clothes as well as differences in each part were significant. As a whole the breast part showed the highest thermal resistance and the leg part was higher than the shank part. The rank of the total thermal resistance was put at Wa>Wv>Ca>Cv>Aa>Av>Ra>Rv in this order. 2. Considered clothing microclimate microclimate temperature has a similar tendency to the total thermal resistance. It showed a significance in the differences of eight clothes and each parts. the belly part was highest in every combination. On the other hand for clothing humidity there was a significance between back and breast part only in the human wearing test. 3. It was indicated that CLO value was highly positively correlated with the clothings' weight and showed a high negative correlation with the air permeability.

  • PDF

Effect of Temperature on the Development of the Ash-gray Leaf Bug, Piesma maculata (Insecta, Hemiptera, Piesmatidae) (온도가 두줄명아주노린재의 발육에 미치는 영향 (곤충망, 매미목, 명아주노린재과))

  • Park, Pil Ryoun;Sang Ock Park
    • The Korean Journal of Ecology
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 1983
  • The authors reared the ash-gray leaf bug, Piesma maculata in the growth cabinet controlled as temperature groups of $15, 20, 25, 30, 40^{\circ}C$under condition of photoperiod 16L:8D, light intensity $510{\pm}240$ lus, relative humidity $65{\pm}3%$, and analyzed the effects of temperature on the development of the insect. The results are summarized as follow: There are highly significant differences the developmental periods for the temperature groups, and between the developmental periods for the developmental stages. The egg in the temperature of 15 and $40^{\circ}C$ was hatched, but the ecdysis was impossible. The thermal threshold was $12.34^{\circ}C$and the upper lethal temperature $40.39^{\circ}C$. The total developmental periods of egg to adulate in the temperature of 20, 25, 30 and $35^{\circ}C$are 40.52, 22.37, 15.91 and 13.00 days, respectively. That is, the developmental period was decreased, as the temperature was increased. In the developmental period for the developmental stages, the developmental period of egg stage was longer than that of 25, 30 and $35^{\circ}C$, and that of 25。C was longer than that of $35^{\circ}C$. But ther was not significant differences between the developmental periods for the other temperature group. The rate of hatch at$20^{\circ}C$is the greater value as 90%, and the rates of 25, 30 and $35^{\circ}C$ are 79, 79 and 67%, respectively. That is the rate of hatch was decreased, as the temperature was increased. The mortality in the temperature of $35^{\circ}C$ is the greatest value as 68%, and those of 30, 25 and $20^{\circ}C$are 59, 59 and 41%, respectively. That is, the mortality was increased, as the temperature was increased. There was not significantly differences between the developmental period of female and male.

  • PDF

Analysis of Differences in Indoor Environment and Fatigue Response According to Ventilation in Lecture Hall (대형강의실의 환기여부에 따른 실내환경과 피로감 반응의 차이분석)

  • Oh, Ye-Seul;Hwang, Jin-A;Choi, Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.2
    • /
    • pp.417-428
    • /
    • 2010
  • The purpose of this study was to analyze differences of the indoor environment and student's fatigue response according to ventilation in university lecture hall. The experiments consisted of measuring the indoor environmental parameters and a survey of student's responses. The experiments were in the lecture hall that the actual lecture was conducted in on the $25^{th}$ of May 2009 (not opening windows and door- A) and the $1^{st}$ of June 2009 (opening windows and door- B). The experimental variable was ventilation by opening the windows and door, and the controlled conditions were indoor temperature by air conditioner, volume of the microphone and VTR, lighting conditions and teaching method. The results are as follows: 1) The indoor temperature was maintained in controlling A, B but the $CO_2$ and relative humidity of A (average 3579ppm, 62.6%) was higher than B (average 1697ppm, 48.1%). 2) There were differences in the student's subjective responses and student's fatigue responses between A and B. 3) Therefore, it was found that ventilation by opening the windows and door was a valid way to improve the relative humidity and to reduce $CO_2$ in the lecture hall.

Meteorological Characteristics in the Ulsan Metropolitan Region: Focus on Air Temperature and Winds (울산지역의 기상 특성: 기온과 바람을 중심으로)

  • Oh, Inbo;Bang, Jin-Hee;Kim, Yangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.181-194
    • /
    • 2015
  • Spatial-temporal meteorological features of the Ulsan metropolitan region (UMR) were analyzed using observations and high-resolution numerical modeling. Long-term trend analysis (1970~2013) showed a significant increase of $0.033^{\circ}Cyr^{-1}$ in the 5-year moving average temperature, although detailed short-term features varied, whereas wind speed and relative humidity over the same period displayed clear decreases of $-0.007ms^{-1}$ and $-0.29%yr^{-1}$, respectively. These trends indicate the effects of regional climate change and urbanization in the UMR. Seasonal variations averaged for the most recent three years, 2011~2013, showed that temperatures in three different regions (urban/industrial, suburban, coastal areas) of the UMR had similar seasonality, but significant differences among them were observed for a certain season. Urban and industrial complex regions were characterized by relatively higher temperatures with large differences (max.: $3.6^{\circ}C$) from that in the coastal area in summer. For wind speed, strong values in the range from 3.3 to $3.9ms^{-1}$ occurred in the coastal areas, with large differences clearly shown between the three regions in September and October. Diurnal variations of temperature were characterized by pronounced differences during the daytime (in summer) or nighttime (in winter) between the three regions. Results from the WRF modeling performed for four months of 2012 showed large variations in gridaverage temperature and winds in the UMR, which displayed significant changes by season. Especially, a clear temperature rise in the urban center was identified in July ($0.6^{\circ}C$ higher than nearby urban areas), and overall, relatively weak winds were simulated over urban and inland suburban regions in all seasons.

The Effect of Thermal Storage/Release and Moisture Transport Properties of Polyethylene Glycol-Treated Acrylic Athletic Socks on the Wear Performance (Polyethylene Glycol 처리한 아크릴 운동용 양말의 축열 . 방열성과 수분전달 특성이 착용 성능에 미치는 영향)

  • 조길수;이은주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.1
    • /
    • pp.36-50
    • /
    • 1995
  • The purpose of this study was 1) to estimate the improvement of thermal storage/release and moisture transport properties of PEG-treated acrylic athletic socks and suggest the optimum add-on for PEG treatment, 2) to investigate wear performance of untreated cocks and two kinds of socks treated with PEG of minimum and optimum add-on respectively, and 3) to consider the effect of thermal storage/release and moisture transport properties of PEG- treated socks on the wear performance and the subjective comfort zone. Thermal activities of specimens treated by PDC were evaluated on a DSC by measuring the heat of fusion on heating and the heat of crystallization on cooling. Moisture regain, absorption speed, wickability, water retenti on value, and water-vapor permeability were measured. In the wear trials that the subjects performed a subsequent exercise protocol wearing three differently treated socks in a conditioned environment ($14\pm2^{\circ}C$, 65$\pm$2% R.H.), microclimate temperature and humidity, and subjective wear sensations including thermal sensation, wettedness, softness, fit, and overall comfort were obtained. PEC-treated specimens with more than 20% add-on showed thermal storage on heating and thermal release on cooling by a DSC and the heat contents of treated ones were generally proportional to the add-ons. Moisture transport properties were highly improved after PEG treatment and increased rapidly with increasing add-on. The tendencies were, however, relaxed above 50% add-on and the treated knits were much stiffer above that add-on. In the wear trials of untreated, PEG add-on 20%, and 50% acrylic socks, the changes of microclimate temperature of 50% socks were significantly less than that of 20% socks. PEG add-on 50% socks showed significantly less changes of microclimate humidity than other two kinds of socks. Three kinds of socks showed significant differences in overall comfort and add-on 50% socks were accepted more comfortable than other two kinds of socks. Comfort zone of foot was extended after PEG treatment on socks and it implied that the subjects wearing PEG- treated socks felt comfortable in wider ranges of microclimate temperature and humidity.

  • PDF