Spectral Characteristics of Release Bursts (개방 파열의 스펙트럼상의 특성)

  • Park Hansang
    • Proceedings of the KSPS conference
    • /
    • 2003.10a
    • /
    • pp.159-162
    • /
    • 2003
  • This study investigates Korean phonation types in terms of spectral characteristics of release bursts. Particularly, this study compares intensity of the speech signal in the release burst, the center of gravity and skewness of the spectra of the release bursts across phonation types for the Korean alveolar plosives. The results showed that there was no significant difference in intensity, center of gravity, or skewness across phonation types but a significant difference across speakers.

  • PDF

A Diagnosis Method of Basal Cell Carcinoma by Raman Spectra of Skin Tissue using NMF Algorithm (피부 조직의 라만 스펙트럼에서 NMF 알고리즘을 통한 기저 세포암 진단 방법)

  • Park, Aaron;Baek, Sung-June
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.196-202
    • /
    • 2013
  • Basal cell carcinoma (BCC) is the most common skin cancer and its incidence is increasing rapidly. In this paper, we propose a diagnosis method of basal cell carcinoma by Raman spectra of skin tissue using the NMF(non-negative matrix factorization) algorithm. After preprocessing steps, measured Raman spectra is used classification experiments. The weight and the basis can be obtained in a simple matrix operation and a column vector of the matrix decompsed by the NMF. Linear combination of bases and weights, it is possible to approximate the average of Raman spectra. The classification method is to select the class which to minimize the root mean square of the difference of the linear combination and the objective spectrum. According to the experimental results, the proposed method shows the promising results to diagnosis BCC. In addition, it confirmed that the proposed method compared with the previous research result could be effectively applied in the analysis of the Raman spectra.

Examining Synchronous Fluorescence Spectra of Dissolved Organic Matter for River BOD Prediction (하천수 BOD 예측을 위한 용존 자연유기물질의 synchronous 형광 스펙트럼 분석)

  • Hur, Jin;Park, Min-Hye
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.236-243
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter (DOM) have the superior advantages over other analysis tools for the applications to water quality management due to their rapid analysis. It is known that protein-like fluorescence characteristics are well corelated with microbial activities and biodegradable organic matter. In this study, potential biochemical oxygen demand (BOD) predictor were explored using the fluorescence peak intensities and/or the integrated fluorescence intensities derived from synchronous fluorescence spectra and the first derivative spectra of river samples. A preliminary study was conducted using a mixture of a river and a treated sewage to test the feasibility of the approach. It was demonstrated that the better BOD predictor can be derived from synchronous fluorescence spectra and the derivatives when the difference between the emission and the excitation wavelengths (${\Delta}{\gamma}$) was large. The efficacy of several selected fluorescence parameters was rivers in Seoul. The fluorescence parameters exhibited relatively good correlation coefficients with the BOD values, ranging from 0.59 to 0.90. Two parameters were suggested to be the optimum BOD predictors, which were a fluorescence peak at a wavelength of 283 nm from the synchronous spectrum at the ${\Delta}{\gamma}$ value of 75 nm, and the integrated fluorescence intensity of the first derivatives of the spectra at the wavelength range between 245 nm and 280 nm. Each BOD predictor showed the correlation coefficients of 0.89 and 0.90, respectively. It is expected that the results of this study will provide important information to develop a real-time efficient sensor for river BOD in the future.

The Prediction of Blending Ratio of Cut Tobacco, Expanded Stem, and Expanded Cut Tobacco in Cigarettes using Near Infrared Spectroscopy (근적외분광법을 이용한 권련 중 일반각초, 팽화주맥 및 팽화각초 배합비 분석)

  • 김용옥;정한주;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • This study was carried out to predict blending ratio of cut tobacco(CT), expanded stem(ES), and expanded cut tobacco(ECT) in cigarettes. CT, ES, and ECT samples from A brand were, ground and blended with reference to A blending ratio, and scanned by near infrared spectroscopy(NIRSystem Co., Model 6500). Calibration equations were developed and then determined blending ratio by NIRS. The standard error of calibration(SEC) and performance(SEP) of C factory samples between NIRS and known blending ratio were 0.97%, 1.93% for CT, 0.50%, 1.12 % for ES and 0.68%, 1.10% for ECT, respectively. The SEP of CT, ES and ECT of Band D factory samples determined by C factory calibration equation were more inaccurate than those of C factory samples determined by C factory calibration equations. These results were caused by the difference of CT, ES and ECT spectra followed by each factory. The SEP of CT, ES and ECT of Band D factories determined by calibration equations derived from each factory samples were more accurate than those of determined by calibration equation derived from C factory samples. Each factory SEP of CT, ES and ECT determined by calibration equation derived from all calibration samples(B+C+D factory) was similar to that determined by calibration equation derived from each factory samples. To improve the analytical inaccuracy caused by spectra difference, we need to apply a specific calibration equation for each factory sample. Data in development of specific calibrations between sample and NIRS spectra might supply a method for rapid determination of blending ratio of CT, ES, and ECT.

  • PDF

Properties of $Cl^-$ Binding Site in Oxygen-Evolving Complex of Photosystem II Studied by FTIR Spectroscopy

  • Koji Hasegawa;Kim, Yukihiro ura;Asako Ishii;Jun Minagawa;Ono, Taka-aki
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.376-378
    • /
    • 2002
  • Role of cl$^{[-10]}$ in photosynthetic oxygen-evolving complex was studied by light-induced Fourier transform infrared (FTIR) spectroscopy. cl$^{[-10]}$ depletion resulted in the suppression of amide I and amide II IR modes upon S$_1$ to S$_2$ transition. Br$^{[-10]}$ , 1$^{[-10]}$ and N0$_3$$^{[-10]}$ substituted FTIR difference spectra were very similar to that in cl$^{[-10]}$ reconstitution. F$^{[-10]}$ and $CH_3$COO$^{[-10]}$ substituted spectra were largely distorted. We succeeded in detecting the structural change of N0$_3$ $^{[-10]}$ in the cl$^{[-10]}$ site upon the S$_1$ to S$_2$ transition from $^{14}$ N0$_3$$^{[-10]}$ /$^{15}$ N0$_3$$^{[-10]}$ difference spectrum.

  • PDF

Detection of Microphytobenthos in the Saemangeum Tidal Flat by Linear Spectral Unmixing Method

  • Lee Yoon-Kyung;Ryu Joo-Hyung;Won Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.5
    • /
    • pp.405-415
    • /
    • 2005
  • It is difficult to classify tidal flat surface that is composed of a mixture of mud, sand, water and microphytobenthos. We used a Linear Spectral Unmixing (LSU) method for effectively classifying the tidal flat surface characteristics within a pixel. This study aims at 1) detecting algal mat using LSU in the Saemangeum tidal flats, 2) determining a suitable end-member selection method in tidal flats, and 3) find out a habitual characteristics of algal mat. Two types of end-member were built; one is a reference end-member derived from field spectrometer measurements and the other image end-member. A field spectrometer was used to measure spectral reflectance, and a spectral library was accomplished by shape difference of spectra, r.m.s. difference of spectra, continuum removal and Mann-Whitney U-test. Reference end-members were extracted from the spectral library. Image end-members were obtained by applying Principle Component Analysis (PCA) to an image. The LSU method was effective to detect microphytobenthos, and successfully classified the intertidal zone into algal mat, sediment, and water body components. The reference end-member was slightly more effective than the image end-member for the classification. Fine grained upper tidal flat is generally considered as a rich habitat for algal mat. We also identified unusual microphytobenthos that inhabited coarse grained lower tidal flats.

Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.

Comparison of optical reflectance spectrum at blade and vein parts of cabbage and kale leaves

  • Ngo, Viet-Duc;Ryu, Dong-Ki;Chung, Sun-Ok;Park, Sang-Un;Kim, Sun-Ju;Park, Jong-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • Objective of the study was to compare reflectance spectrum in the blade and the vein parts of cabbage and kale leaves. A total 6 cabbage and kale leaves were taken from a plant factory in Chungnam National University, Korea. Spectra data were collected with a UV/VIS/NIR spectrometer (model: USB2000, Ocean Optics, FL, USA) in the wavelength region of 190 - 1130 nm. Median filter smoothing method was selected to preprocess the obtained spectra data. We computed reflectance difference by subtraction of averaged spectrum from individual spectrum. To estimate correlation at different parts of cabbage and kale leaves, cross - correlation method was used. Differences between cabbage and kale leaves are clearly manifested in the green, red and near - infrared ranges. The percent reflectance of cabbage leaves in the NIR wavelength band was higher than that of kale leaves. Reflectance in the blade part was higher than in the vein part by 18%. Reflectance difference in the different parts of cabbage and kale leaves were clear in all of the wavelength bands. Standard deviation of reflectance difference in the vein part was greater for kale, while the value in the blade part was greater for cabbage leaves. Standard deviation of cross - correlation increased from 0.092 in the first sensor (UV/VIS) and 0.007 in the second sensor (NIR) to 0.099 and 0.015, respectively.

Effect of Carotenoides on the in vitro Aggregation of Bacteriochlorophyll e

  • Hirabayashi, Hiroki;Ohmura, Satoshi;Ishii, Takasada;Uehara, Kaku
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.370-372
    • /
    • 2002
  • In order to investigate effect of the carotenoids (Car) on aggregation of Bacterochlorophyll (BChl) in chlorosome, we studied the spectral difference in aggregates of BChl e formed in the absence and presence of a few kinds of Car in dimethyl sulfoxide (DMSO) -water solution. The absorption spectra of aggregates made of only BChl e and those made of a mixture of BChl e and Car were almost the same. However, the kinetics and circular dichroism (CD) spectra of aggregate of these were markedly different by kind of Car. Specifically, the rate of aggregation for a mixture of BChl e and isorenietene that contains phenyl as end groupe was faster than that for only BChl e. CD spectra of aggregates made of a mixture of BChl e and isorenietene dramatically changed compared to that made of only BChl e. We propose that BChl might form several kinds of rod-like supramolecular structures to in the presence of some kind of Car in chlorosome.

  • PDF

근적외 분광분석법을 이용한 버어리종 잎담배 화학성분 분석

  • 김용옥;장기철;이경구
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 1999
  • This study was carried out to analyze chemical components in burley tobacco using near infrared spectroscopy(NIRS). Samples were collected in '96 and '97 crop year. Calibration equations were developed by modified partial least square. The standard error performance(SEP) of '96 crop year samples between NIRS and standard laboratory analysis were 0.25% for nicotine, 0.18% for total nitrogen, 0.59% for crude ash, 0.32% for ether extracts, and 0.14% for chlorine, respectively. The analytical results of '97 crop year samples were similar to those of '96 crop year samples. The analytical result of '97 crop year samples analyzed by '96 calibration equation was more inaccurate than that of '96 crop year samples. The SEP of '96 or '97 crop year samples applying calibration equation derived from '96 plus '97 crop year samples was similar to that of '96 or '97 crop year samples analyzed by '96 or '97 calibration equation, respectively. The SEP of '97 crop year samples analyzed by calibration equation derived from '96 plus '97 crop year samples was more accurate than that of '97 crop year samples analyzed by '96 calibration equation. To improve the analytical inaccuracy caused by the difference of crop year between calibration and prediction samples, we need to include the prediction sample spectra which were different from calibration sample spectra in recalibration sample spectra, and then develop recalibration equation. The NIRS can apply to analyze burley leaf tobacco, leaf process or tobacco manufacturing process which were required the rapid analytical result.

  • PDF